1 | PERTES DE CHARGE EN MCE EN FONCTION DU DEBIT | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
2 | Tube Souple | Longueur en m | Ø en mm | 1 m3/h | 1.5 m3/h | 2 m3/h | 2.5 m3/h | 3 m3/h | 3.5 m3/h | 4 m3/h |
3 | < 20 m | Ø 25 | 0 | 1 | 2 | 2 | 3 | 4 | 5 | |
4 | Ø 32 | 0 | 0 | 0 | 1 | 1 | 1 | 2 | ||
5 | 20 à 50 m | Ø 25 | 1 | 2 | 4 | 6 | 8 | 10 | - | |
6 | Ø 32 | 0 | 1 | 1 | 2 | 2 | 3 | 4 | ||
7 | 50 à 80 m | Ø 25 | 2 | 4 | 6 | 9 | 10 | - | - | |
8 | Ø 32 | 1 | 1 | 2 | 3 | 4 | 5 | 6 | ||
9 | ||||||||||
10 | PERTES DE CHARGE EN MCE EN FONCTION DU DEBIT | |||||||||
11 | Tube Rigide | Longueur en m | Ø en mm | 2 m3/h | 4 m3/h | 6 m3/h | 8 m3/h | 10 m3/h | 12 m3/h | 15 m3/h |
12 | < 50 m | Ø 33 | 1 | 4 | 8 | - | - | - | - | |
13 | Ø 53 | 0 | 1 | 1 | 2 | 2 | 3 | 4 | ||
14 | Ø 63 | 0 | 0 | 0 | 0 | 1 | 1.5 | 2 | ||
15 | 50 à 100 m | Ø 33 | 2 | 7 | - | - | - | - | - | |
16 | Ø 53 | 0 | 1 | 2 | 3 | 4 | 6 | 8 | ||
17 | Ø 63 | 0 | 0 | 1 | 2 | 2 | 3 | 4 | ||
18 | 100 à 150 m | Ø 33 | 3 | 11 | - | - | - | - | - | |
19 | Ø 53 | 0 | 2 | 3 | 4 | 6 | 9 | 12 | ||
20 | Ø 63 | 0 | 0 | 1 | 2 | 3 | 4 | 6 | ||
21 | 150 à 200 m | Ø 53 | 1 | 2 | 4 | 6 | 8 | - | - | |
22 | Ø 63 | 0 | 0 | 2 | 3 | 4 | 6 | 8 |