1 | www.v2charge.com | |||||||
---|---|---|---|---|---|---|---|---|
2 | Suppor information | |||||||
3 | Releases | |||||||
4 | Last Review | 20/05/24 | Firmware V 2.1.14 | |||||
5 | ||||||||
6 | RS485 Modbus | |||||||
7 | TCP | Port: 502 | Server ID: 1 ( 0x01) | |||||
8 | RTU | Server ID: 20 ( 0x14 ) | ||||||
9 | ||||||||
10 | WRITE HOLDING REGISTER 0X06 | |||||||
11 | REF | UNIT | HEX | TYPE | DESCRIPTION | |||
12 | WRITE_ADDRESS_PAUSE | 6010 | 177A | Int | 0 No pause; 1 pause | |||
13 | WRITE_ADDRESS_LOCK | 6011 | 177B | Int | 0 Unlocked; 1 Blocked | |||
14 | WRITE_ADDRESS_PROMGRAM | 6012 | 177C | Int | Enable / Disable schedule | |||
15 | WRITE_ADDRESS_INTENSITY | 6013 | 177D | Int | 6-32 intensity value | |||
16 | WRITE_ADDRESS_DYNAMIC | 6014 | 177E | Int | Dynamic control on / off | |||
17 | WRITE_ADDRESS_PAYMENT | 6015 | 177F | Int | Payments enable / disable | |||
18 | WRITE_ADDRESS_OCPP | 6016 | 1780 | Int | OCPP Enable / Disable | |||
19 | WRITE_ADDRESS_MIN_INTENSITY | 6017 | 1781 | Int | Set minimun Intensity limit (A) | |||
20 | WRITE_ADDRESS_MAX_INTENSITY | 6018 | 1782 | Int | Set maximun Intensity limit (A) | |||
21 | WRITE_ADDRESS_PAUSE_DYNAMIC | 6019 | 1783 | Int | 1 Pause Dynamic Control Modulation 0 Resume Dynamic Control Modulation | |||
22 | WRITE_ADDRESS_DYNAMIC_POWER_MODE | 6020 | 1784 | Int | 0 Enable Timed Power; 1 Disable Timed Power 2 Disable Timed Power and set Exclusive Mode 3 Disable Timed Power and set Min Power Mode 4 Disable Timed Power and set Grid+FV mode 5 Disable Timed Power and set Stop Mode | 2, 3 and 4 FV modes setted only have effect in FV installations | ||
23 | WRITE_ADDRESS_CONTRACTED_POWER | 6021 | 1785 | Int | Set Contracted Power in Watts | Only enabled when Timer Power is disabled and FV mode setted different to Exclusive | ||
24 | WRITE_ADDRESS_GRID_POWER | 6022 | 1786 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of grid consumption) Positive or Negative values | |||
25 | WRITE_ADDRESS_SUN_POWER | 6023 | 1787 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of solar Energy) Positive Values | |||
26 | WRITE_ADDRESS_BATTERY_POWER | 6024 | 1788 | Int | Modbus Feeder config in Dynamic Power Control DPC (send information of power of Battery) Positive or Negative values | |||
27 | WRITE_ADDRESS_VOLTAGE | 6025 | 1789 | Int | Send Voltage of installation to the charger | |||
28 | ||||||||
29 | ||||||||
30 | ||||||||
31 | ||||||||
32 | READ HOLDING REGISTER 0X03 | |||||||
33 | REF | UNIT | HEX | TYPE | DESCRIPTION | WORDS (UINT16) | ||
34 | READ_ADDRESS_CHARGE_STATE | 3010 | BC2 | Float (Big Endian) | 0,1,2, (A, B, C) | 2 | ||
35 | READ_ADDRESS_CHARGE_POWER | 3011 | BC3 | Float (Big Endian) | Charger Power (Watt) | 2 | ||
36 | READ_ADDRESS_CHARGE_ENERGY | 3012 | BC4 | Float (Big Endian) | Energy in (kWh) | 2 | ||
37 | READ_ADDRESS_SLAVE_ERROR | 3013 | BC5 | Float (Big Endian) | 00 No error 01 Communication 02 Reading 03 Slave 04 Waiting WiFi 05 Waiting communication 06 Wrong IP 07 Slave not found 08 Wrong Slave 09 No response 10 Clamp not connected | 2 | ||
38 | READ_ADDRESS_CHARGE_TIME | 3014 | BC6 | Float (Big Endian) | Load time in seconds | 2 | ||
39 | READ_ADDRESS_PWM_VALUE | 3015 | BC7 | Float (Big Endian) | ADC PWM value | 2 | ||
40 | READ_ADDRESS_HOUSE_POWER | 3016 | BC8 | Float (Big Endian) | House Power (Watt) | 2 | ||
41 | READ_ADDRESS_FV_POWER | 3017 | BC9 | Float (Big Endian) | PV Power (Watt) | 2 | ||
42 | READ_ADDRESS_PAUSE | 3018 | BCA | Float (Big Endian) | Pause status information | 2 | ||
43 | READ_ADDRESS_LOCK | 3019 | BCB | Float (Big Endian) | Locked status information | 2 | ||
44 | READ_ADDRESS_PROMGRAM | 3020 | BCC | Float (Big Endian) | Scheduled status information | 2 | ||
45 | READ_ADDRESS_INTENSITY | 3021 | BCD | Float (Big Endian) | Current intensity | 2 | ||
46 | READ_ADDRESS_DYNAMIC | 3022 | BCE | Float (Big Endian) | Active dynamic control status information | 2 | ||
47 | READ_ADDRESS_PAYMENT | 3023 | BCF | Float (Big Endian) | Payment Active status information | 2 | ||
48 | READ_ADDRESS_OCPP | 3024 | BD0 | Float (Big Endian) | OCPP active status information | 2 | ||
49 | READ_ADDRESS_MIN_INTENSITY | 3025 | BD1 | Float (Big Endian) | Minimun Intensity limit (A) | 2 | ||
50 | READ_ADDRESS_MAX_INTENSITY | 3026 | BD2 | Float (Big Endian) | Maximun Intensity limit (A) | 2 | ||
51 | READ_ADDRESS_PAUSE_DYNAMIC | 3027 | BD3 | Float (Big Endian) | 1 Dynamic Control Modulation Pause 0 Dynamic Control Modulation Working | 2 | ||
52 | READ_ADDRESS_DYNAMIC_POWER_MODE | 3028 | BD4 | Float (Big Endian) | 0 Timed Power enabled; 1 Timed Power Disabled 2 Timed Power Disabled and Exclusive Mode setted 3 Timed Power Disabled and Min Power Mode setted 4 Timed Power Disabled and Grid+FV mode setted 5 Timed Power Disabled and Stop Mode setted | 2 | ||
53 | READ_ADDRESS_CONTRACTED_POWER | 3029 | BD5 | Float (Big Endian) | Contracted Power in Watts | 2 | (-1 when Timer Power is disabled or FV mode is setted to Exclusive) | |
54 | READ_ADDRESS_VOLTAGE | 3030 | BD6 | Float (Big Endian) | Voltage of installation (V) | 2 | ||
55 | ||||||||
56 | ||||||||
57 | ||||||||
58 | ||||||||
59 | Do you need more register? Please send us an improvement | |||||||
60 |
1 | www.v2charge.com | |||||
---|---|---|---|---|---|---|
2 | Suppor information | |||||
3 | Releases | |||||
4 | Last Review | 20/05/24 | ||||
5 | ||||||
6 | HTTP GET REQUESTS | |||||
7 | READ DATA | http://XXX.XXX.XXX.XXX/RealTimeData | From version 2.1.16 | |||
8 | WRITE DATA | http://XXX.XXX.XXX.XXX/write/KeyWord=Value | ||||
9 | ||||||
10 | ||||||
11 | READ DATA RESPONSE TYPE | |||||
12 | {"ID":"XXXXXX","ChargeState":0,"ChargePower":0.00,"VoltageInstallation":0,"ChargeEnergy":0.00,"SlaveError":0,"ChargeTime":0,"HousePower":0,"FVPower":0.00,"Paused":0,"Locked":0,"Timer":0,"Intensity":6,"Dynamic":0, "MinIntensity":6,"MaxIntensity":32,"PauseDynamic":0,"DynamicPowerMode":1,"ContractedPower":4700,"SSID":"ssid","IP":"0.0.0.0","SignalStatus":3} | |||||
13 | ||||||
14 | ||||||
15 | ||||||
16 | WRITE DATA AND KEYWORDS DESCRIPTION | |||||
17 | KeyWord | WRITE ENABLED | UNIT | DESCRIPTION | ||
18 | ChargeState | N | N/S | Charge Point state | ||
19 | ChargePower | N | W | Current charging power | ||
20 | VoltageInstallation | Y | V | Installation Voltage | ||
21 | ChargeEnergy | N | kWh | Current charging session energy | ||
22 | SlaveError | N | N/S | Slave communication state: 00 No error 01 Communication 02 Reading 03 Slave 04 Waiting WiFi 05 Waiting communication 06 Wrong IP 07 Slave not found 08 Wrong Slave 09 No response 10 Clamp not connected | ||
23 | ChargeTime | N | s | Current charging session time | ||
24 | HousePower | N | W | House power consumption | ||
25 | FVPower | N | W | Photovoltaic power generation | ||
26 | Paused | Y | N/S | Pause state of current charging session | ||
27 | Locked | Y | N/S | Disabling state of Charge Point (0 Enabled; 1 Disabled) | ||
28 | Timer | Y | N/S | Charge Point Timer state (1 Timer ON; 0 Timer OFF) | ||
29 | Intensity | Y | A | Intensity offered by Charge Point | ||
30 | Dynamic | Y | N/S | Dynamic Intensity Modulation state (0 Disabled; 1 Enabled) | ||
31 | MinIntensity | Y | A | Intensity offered minimun limit | ||
32 | MaxIntensity | Y | A | Intensity offered maximun limit | ||
33 | PauseDynamic | Y | N/S | Dynamic Control Modulation Pause State (0 Modulating; 1 No Modulating) | ||
34 | DynamicPowerMode | Y | N/S | 0 Timed Power enabled; 1 Timed Power Disabled 2 Timed Power Disabled and Exclusive Mode setted 3 Timed Power Disabled and Min Power Mode setted 4 Timed Power Disabled and Grid+FV mode setted 5 Timed Power Disabled and Stop Mode setted | ||
35 | ContractedPower | Y | W | Contracted Power in Watts | ||
36 | ||||||
37 | ||||||
38 | ||||||
39 | ||||||
40 | ||||||
41 | ||||||
42 | ||||||
43 | ||||||
44 | ||||||
45 | ||||||
46 | ||||||
47 | ||||||
48 | ||||||
49 | ||||||
50 | ||||||
51 | ||||||
52 | ||||||
53 | ||||||
54 | ||||||
55 | ||||||
56 | ||||||
57 | ||||||
58 | ||||||
59 | ||||||
60 | Do you need more register? Please send us an improvement | |||||
61 | https://v2charge.atlassian.net/servicedesk/customer/portal/3 |