A | B | C | D | E | F | G | H | I | J | K | L | M | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | TASK_KEY | TASK_DESC | SCTID | FSN | CONCEPT_TYPE | SEVERITY | ACTION_TYPE | DefnStatus | TemplateMatched | IsComplex | IsOrphanet | Template Diagnostic | |
2 | HAS INTENT is currently mandatory and should be optional | MAIN-1 | TemplateCompliance: 1 | 429806006 | Fluoroscopic dacryocystography with insertion of stent (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 280426002 |Lacrimal drainage structure (body structure)| } A{ [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 280426002 |Lacrimal drainage structure (body structure)| } | ||
3 | DIRECT DEVICE has been added to imaging RG recently | MAIN-1 | TemplateCompliance: 1 | 443532008 | Percutaneous insertion of stent into right ventricular outflow tract using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 44627009 |Structure of outflow tract of right ventricle (body structure)| } { [I2] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 44627009 |Structure of outflow tract of right ventricle (body structure)| } | ||
4 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 715275000 | Insertion of bioabsorbable stent into bowel using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I2] 363699004 |Direct device (attribute)| -> 705632009 |Bioabsorbable stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 113276009 |Intestinal structure (body structure)| } { [I3] 363699004 |Direct device (attribute)| -> 705632009 |Bioabsorbable stent (physical object)|, [I3] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I3] 405814001 |Procedure site - Indirect (attribute)| -> 113276009 |Intestinal structure (body structure)| } | ||
5 | ok as has incision RG | MAIN-1 | TemplateCompliance: 1 | 76518007 | Reinsertion of ureteral stent with ureterotomy (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 787145007 |Reinsertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } A{ [I2] 260686004 |Method (attribute)| -> 129287005 |Incision - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
6 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 770703006 | Insertion of stent into ureter using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
7 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 770706003 | Insertion of stent into urethra using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286576009 |Urethral stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 13648007 |Urethral structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286576009 |Urethral stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 13648007 |Urethral structure (body structure)| } | ||
8 | ok has closure RG | MAIN-1 | TemplateCompliance: 1 | 233141007 | Placement of stent in ductus arteriosus and banding of both pulmonary arteries (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 260686004 |Method (attribute)| -> 129357001 |Closure - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 50408007 |Structure of left pulmonary artery (body structure)|, [I1] 424226004 |Using device (attribute)| -> 360221003 |Surgical band (physical object)| } A{ [I2] 260686004 |Method (attribute)| -> 129357001 |Closure - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 78480002 |Structure of right pulmonary artery (body structure)|, [I2] 424226004 |Using device (attribute)| -> 360221003 |Surgical band (physical object)| } { [I3] 363699004 |Direct device (attribute)| -> 360046005 |Arterial stent (physical object)|, [I3] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I3] 405814001 |Procedure site - Indirect (attribute)| -> 4432005 |Structure of ductus arteriosus (body structure)| } | ||
9 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 432811002 | Insertion of stent using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)| } A{ [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)| } | ||
10 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 431221001 | Retrograde insertion of ureteric stent using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
11 | DIRECT DEVICE | MAIN-1 | TemplateCompliance: 1 | 770699008 | Insertion of stent into duodenum using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 468793006 |Duodenal stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 38848004 |Duodenal structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 468793006 |Duodenal stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 38848004 |Duodenal structure (body structure)| } | ||
12 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 718030008 | Antegrade insertion of ureteric stent into ureter of transplanted kidney using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
13 | Repair RG | MAIN-2 | TemplateCompliance: 2 | 1231787007 | Endovascular repair of thoracic aorta using fenestrated stent graft (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 257903006 |Repair - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 113262008 |Thoracic aorta structure (body structure)|, [I1] 424876005 |Surgical approach (attribute)| -> 261449002 |Transluminal approach (qualifier value)| } { [I2] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I2] 363699004 |Direct device (attribute)| -> 1208815007 |Aortic endovascular stent graft (physical object)|, [I2] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 113262008 |Thoracic aorta structure (body structure)|, [I2] 424876005 |Surgical approach (attribute)| -> 261449002 |Transluminal approach (qualifier value)| } | ||
14 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 770700009 | Insertion of stent into bronchus using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 705631002 |Bronchial stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 955009 |Bronchial structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 705631002 |Bronchial stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 955009 |Bronchial structure (body structure)| } | ||
15 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 426585001 | Imaging guided insertion of colorectal stent (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 14742008 |Structure of large intestine (body structure)| } A{ [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 360037004 |Imaging - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 14742008 |Structure of large intestine (body structure)| } | ||
16 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 438823003 | Percutaneous transluminal insertion of metallic stent into bile duct using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I1] 363699004 |Direct device (attribute)| -> 257363003 |Metal stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 28273000 |Bile duct structure (body structure)|, [I1] 424876005 |Surgical approach (attribute)| -> 261449002 |Transluminal approach (qualifier value)| } A{ [I2] 363699004 |Direct device (attribute)| -> 257363003 |Metal stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 28273000 |Bile duct structure (body structure)| } | ||
17 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 432944007 | Percutaneous insertion of nephrovesical stent using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
18 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 715313002 | Insertion of stent into bowel using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 113276009 |Intestinal structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 113276009 |Intestinal structure (body structure)| } | ||
19 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 770697005 | Insertion of stent into bile duct using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 360123005 |Biliary stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 28273000 |Bile duct structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 360123005 |Biliary stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 28273000 |Bile duct structure (body structure)| } | ||
20 | DIRECT DEVICE | MAIN-2 | TemplateCompliance: 2 | 719897001 | Insertion of bioabsorbable stent into airway using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I2] 363699004 |Direct device (attribute)| -> 705632009 |Bioabsorbable stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 89187006 |Airway structure (body structure)| } { [I3] 363699004 |Direct device (attribute)| -> 705632009 |Bioabsorbable stent (physical object)|, [I3] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I3] 405814001 |Procedure site - Indirect (attribute)| -> 89187006 |Airway structure (body structure)| } | ||
21 | Bypass RG | MAIN-2 | TemplateCompliance: 2 | 726011000 | Placement of stent in coronary artery bypass graft (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 705643001 |Coronary artery stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 41801008 |Coronary artery structure (body structure)| } A{ [I2] 260686004 |Method (attribute)| -> 360021005 |Bypass - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 41801008 |Coronary artery structure (body structure)| } | ||
22 | Incision RG | MAIN-3 | TemplateCompliance: 3 | 3559005 | Insertion of ureteral stent with ureterotomy (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } A{ [I2] 260686004 |Method (attribute)| -> 129287005 |Incision - action (qualifier value)|, [I2] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
23 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 440457004 | Percutaneous transluminal insertion of plastic stent into bile duct using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 701406003 |Polymeric biliary stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 28273000 |Bile duct structure (body structure)| } { [I2] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I2] 363699004 |Direct device (attribute)| -> 701406003 |Polymeric biliary stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 28273000 |Bile duct structure (body structure)|, [I2] 424876005 |Surgical approach (attribute)| -> 261449002 |Transluminal approach (qualifier value)| } | ||
24 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 430434007 | Insertion of stent using computed tomography guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312251004 |Computed tomography imaging - action (qualifier value)| } { [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)| } | ||
25 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 770701008 | Insert of stent into esophagus using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 705472007 |Esophageal stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 32849002 |Esophageal structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 705472007 |Esophageal stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 32849002 |Esophageal structure (body structure)| } | ||
26 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 431219006 | Antegrade insertion of ureteric stent using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
27 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 773292009 | Insertion of stent into trachea using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 44567001 |Tracheal structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 44567001 |Tracheal structure (body structure)| } | ||
28 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 1296517003 | Percutaneous transfemoral insertion of stent into extracranial carotid artery using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 260507000 |Access (attribute)| -> 103388001 |Percutaneous approach - access (qualifier value)|, [I1] 363699004 |Direct device (attribute)| -> 413766009 |Carotid artery stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 425362007 |Surgical insertion - action (qualifier value)|, [I1] 405814001 |Procedure site - Indirect (attribute)| -> 86117002 |Internal carotid artery structure (body structure)|, [I1] 424876005 |Surgical approach (attribute)| -> 261449002 |Transluminal approach (qualifier value)| } A{ [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 86117002 |Internal carotid artery structure (body structure)| } | ||
29 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 432586006 | Insertion of stent using ultrasound guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 278292003 |Ultrasound imaging - action (qualifier value)| } { [I2] 363699004 |Direct device (attribute)| -> 65818007 |Stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)| } | ||
30 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 433594009 | Insertion of metallic stent using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | SD | N | N | Cardinality mismatch: N/A Relationship Group mismatches: { [I1] 363699004 |Direct device (attribute)| -> 257363003 |Metal stent (physical object)|, [I1] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)| } A{ [I2] 363699004 |Direct device (attribute)| -> 257363003 |Metal stent (physical object)|, [I2] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I2] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)| } | ||
31 | DIRECT DEVICE | MAIN-3 | TemplateCompliance: 3 | 718031007 | Retrograde insertion of ureteric stent into ureter of transplanted kidney using fluoroscopic guidance (procedure) | MEDIUM | VALIDATION_CHECK | P | N | N | Cardinality mismatch: N/A Relationship Group mismatches: A{ [I1] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I1] 363703001 |Has intent (attribute)| -> 429892002 |Guidance intent (qualifier value)|, [I1] 260686004 |Method (attribute)| -> 312275004 |Fluoroscopic imaging - action (qualifier value)|, [I1] 405813007 |Procedure site - Direct (attribute)| -> 87953007 |Ureteric structure (body structure)| } { [I2] 363699004 |Direct device (attribute)| -> 286558002 |Ureteric stent (physical object)|, [I2] 260686004 |Method (attribute)| -> 257867005 |Insertion - action (qualifier value)|, [I2] 405814001 |Procedure site - Indirect (attribute)| -> 87953007 |Ureteric structure (body structure)| } | ||
32 | |||||||||||||
33 | |||||||||||||
34 | |||||||||||||
35 | |||||||||||||
36 | |||||||||||||
37 | |||||||||||||
38 | |||||||||||||
39 | |||||||||||||
40 | |||||||||||||
41 | |||||||||||||
42 | |||||||||||||
43 | |||||||||||||
44 | |||||||||||||
45 | |||||||||||||
46 | |||||||||||||
47 | |||||||||||||
48 | |||||||||||||
49 | |||||||||||||
50 | |||||||||||||
51 | |||||||||||||
52 | |||||||||||||
53 | |||||||||||||
54 | |||||||||||||
55 | |||||||||||||
56 | |||||||||||||
57 | |||||||||||||
58 | |||||||||||||
59 | |||||||||||||
60 | |||||||||||||
61 | |||||||||||||
62 | |||||||||||||
63 | |||||||||||||
64 | |||||||||||||
65 | |||||||||||||
66 | |||||||||||||
67 | |||||||||||||
68 | |||||||||||||
69 | |||||||||||||
70 | |||||||||||||
71 | |||||||||||||
72 | |||||||||||||
73 | |||||||||||||
74 | |||||||||||||
75 | |||||||||||||
76 | |||||||||||||
77 | |||||||||||||
78 | |||||||||||||
79 | |||||||||||||
80 | |||||||||||||
81 | |||||||||||||
82 | |||||||||||||
83 | |||||||||||||
84 | |||||||||||||
85 | |||||||||||||
86 | |||||||||||||
87 | |||||||||||||
88 | |||||||||||||
89 | |||||||||||||
90 | |||||||||||||
91 | |||||||||||||
92 | |||||||||||||
93 | |||||||||||||
94 | |||||||||||||
95 | |||||||||||||
96 | |||||||||||||
97 | |||||||||||||
98 | |||||||||||||
99 | |||||||||||||
100 |