A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Project Completion Checklist | ||||||||||||||||||||||||
2 | Property Address: | Complete | |||||||||||||||||||||||
3 | Items to perform first: | MAKE SURE YOU ARE AT THE CORRECT HOUSE by looking at the address of the property in CoConstruct, and the numbers on the house. | |||||||||||||||||||||||
4 | YOU CANNOT mark items complete that are not complete. WE CANNOT FIX PROBLEMS IF WE DON'T KNOW THEY EXIST!! This means YOU! Every single time. | ||||||||||||||||||||||||
5 | 1. Run water (both hot and cold) in the bath tub for at least 5 minutes to clear any sediment in the lines. | ||||||||||||||||||||||||
6 | IF THERE IS NO BATHTUB, REMOVE THE SHOWER HEAD and run water through the shower head arm. | ||||||||||||||||||||||||
7 | 2. Fill all sinks with water. Observe water pressure. If pressure is low, see items 2a-c. If there is low pressure, there is generally a fixable cause that does not involve ripping the pipes out of the walls or the ground! If pressure is good, proceed to 3. | ||||||||||||||||||||||||
8 | 2a. Unscrew the aerator from the faucet and wipe it with your finger to remove any sediment clogging the aerator. | ||||||||||||||||||||||||
9 | 2b. Check the main shutoff valve where the water enters the house. Is it fully open? **Provide a picture** | ||||||||||||||||||||||||
10 | 2c. Is the valve fully open at the water meter outside the house? **Provide a picture** | ||||||||||||||||||||||||
11 | 3. Drain all sinks to verify that the pipes work as they should and there are no leaks. | ||||||||||||||||||||||||
12 | Kitchen: | Light fixtures/fans and light bulbs operate properly | |||||||||||||||||||||||
13 | Blinds installed | ||||||||||||||||||||||||
14 | Electrical outlets work properly (check GFI) any outlet within 6' of a water source must be Gfci | ||||||||||||||||||||||||
15 | Sink has hot/cold water & drains properly *Let the hot water run for a minute. It might not be hot when you first turn it on! | ||||||||||||||||||||||||
16 | Disposal works properly RUN WATER WHEN TESTING THIS; safety cover over switch | ||||||||||||||||||||||||
17 | Disposal wrench on all disposals | ||||||||||||||||||||||||
18 | Check under sink for leaks | ||||||||||||||||||||||||
19 | Cabinets are securely attached to the wall. PHYSICALLY TOUCH to make sure they don't rotate or move. | ||||||||||||||||||||||||
20 | Cabinets are level, and doors & drawers open/close - and are clean | ||||||||||||||||||||||||
21 | Remove all trash | ||||||||||||||||||||||||
22 | Bottle opener installed | ||||||||||||||||||||||||
23 | PHYSICALLY TOUCH AND MOVE/PULL Sinks and other appliances to make sure they are installed properly | ||||||||||||||||||||||||
24 | Appliances: | All appliances are level - dishwasher & range are level & at proper height | |||||||||||||||||||||||
25 | Refrigerator cools/icemaker works | ||||||||||||||||||||||||
26 | Dishwasher runs & drains properly; toe kick installed | ||||||||||||||||||||||||
27 | Microwave works & set time | ||||||||||||||||||||||||
28 | Oven heats/stove works & set time | ||||||||||||||||||||||||
29 | Make sure clean filter is installed in HVAC unit, and record size | ||||||||||||||||||||||||
30 | Remove plastic film and stickers from appliances and sink drains | ||||||||||||||||||||||||
31 | Interior: | Check drywall for imperfections; circle with carpenter's pencil | |||||||||||||||||||||||
32 | Remove all trash | ||||||||||||||||||||||||
33 | All Bedrooms: | ||||||||||||||||||||||||
34 | Light fixtures/fans and light bulbs operate properly | ||||||||||||||||||||||||
35 | Closet system secure, shelves straight - must have hanging bar to be considered closet | ||||||||||||||||||||||||
36 | Doors open/close/lock properly (including closet), do not stick, stay shut when closed, and have door stops | ||||||||||||||||||||||||
37 | Blinds installed | ||||||||||||||||||||||||
38 | Electrical outlets work properly | ||||||||||||||||||||||||
39 | Windows open & close, do not stick, must stay open in intended position and are locked | ||||||||||||||||||||||||
40 | PHYSICALLY TOUCH AND MOVE/PULL items to make sure they are installed properly | ||||||||||||||||||||||||
41 | All Bathrooms: | ||||||||||||||||||||||||
42 | Light fixtures/exhaust fans and light bulbs operate properly | ||||||||||||||||||||||||
43 | Doors open/close/lock properly (including closet), do not stick, stay shut when closed, and have door stops | ||||||||||||||||||||||||
44 | Bottom of mirror is no higher than 4.5 feet from floor | ||||||||||||||||||||||||
45 | Towel bars/TP holder/Shower curtain rod installed | ||||||||||||||||||||||||
46 | Toilet flushes & refills properly | ||||||||||||||||||||||||
47 | Toilet - lift the top of the tank, and verify the water fill line is 1/2" below the top of the overflow tube | ||||||||||||||||||||||||
48 | Plunger is available (1) | ||||||||||||||||||||||||
49 | Shower/tub has hot/cold water & drains properly/drain cover | ||||||||||||||||||||||||
50 | PHYSICALLY PRESS YOUR HAND AGAINST the tub shower assembly to make sure it is not loose | ||||||||||||||||||||||||
51 | Sink has hot/cold water & drains properly/drain cover | ||||||||||||||||||||||||
52 | Check under sink and toilet for leaks | ||||||||||||||||||||||||
53 | PHYSICALLY PRESS YOUR FOOT AROUND THE BACK OF THE TOILET to make sure the floor is firm | ||||||||||||||||||||||||
54 | PHYSICALLY GRIP THE SIDE OF THE TOILET and rock it side to side, if there is movement, it needs to be reseated | ||||||||||||||||||||||||
55 | Electrical outlets work properly (check GFI) any oulet within 6' of a water source must be Gfci | ||||||||||||||||||||||||
56 | Inspect all grout lines in the tile - make sure silicone is used on any change of angles (ie 90 degree angles on walls) | ||||||||||||||||||||||||
57 | - and around where the shower base or bathtub meet the tiles | ||||||||||||||||||||||||
58 | Check if "hot water" is working in all fixtures | ||||||||||||||||||||||||
59 | PHYSICALLY TOUCH AND MOVE/PULL Sinks and other items to make sure they are installed properly | ||||||||||||||||||||||||
60 | Set the tankless water heater to 112F | ||||||||||||||||||||||||
61 | Living Area: | ||||||||||||||||||||||||
62 | Electrical outlets work properly | ||||||||||||||||||||||||
63 | Smoke detectors work properly, with new batteries - 1 per floor; if gas in unit must have CO2 dectector, 1 per floor | ||||||||||||||||||||||||
64 | Check heat and air by placing your hand over the register to feel if warm or cool air is blowing. You may also use a digital temperature gun to verify the temperature. | ||||||||||||||||||||||||
65 | Set thermostat to 80 (cool) in summer; 55 (heat) in winter. If the thermostat shows a different number, make sure it is turned on and in the proper mode (heat in winter, cool in summer) | ||||||||||||||||||||||||
66 | In what mode is the thermostat set? Heat ___ Cool ___ Off ___ What is the current reading of the thermostat? _____ | ||||||||||||||||||||||||
67 | What is the current reading of the thermostat? ______ What temperature did you set the thermostat to? ________ | ||||||||||||||||||||||||
68 | Windows open/shut/lock properly; leave locked | ||||||||||||||||||||||||
69 | Blinds installed | ||||||||||||||||||||||||
70 | HVAC Filter is clean - record size in property manual | ||||||||||||||||||||||||
71 | put hand over vents to make sure blowing hot air in winter, cold air in summer | ||||||||||||||||||||||||
72 | PHYSICALLY TOUCH AND MOVE/PULL items to make sure they are installed properly | ||||||||||||||||||||||||
73 | Laundry Room: | ||||||||||||||||||||||||
74 | Washer box operational - both hot and cold water, and drains properly | ||||||||||||||||||||||||
75 | Dryer vent installed properly (hard piped to exterior, preferably through crawl) | ||||||||||||||||||||||||
76 | If washer/dryer supplied, make sure they operate and the washer drains properly | ||||||||||||||||||||||||
77 | Drain pan installed under laundry unit, drain line piped to exterior | ||||||||||||||||||||||||
78 | Check water heater pressure relief line | ||||||||||||||||||||||||
79 | PHYSICALLY TOUCH AND MOVE/PULL items to make sure they are installed properly | ||||||||||||||||||||||||
80 | Final Cleaning: | ||||||||||||||||||||||||
81 | Wash windows, inside and out, removing all stickers | ||||||||||||||||||||||||
82 | Sweep and mop all floors; touch up any scratches | ||||||||||||||||||||||||
83 | Clean off countertops | ||||||||||||||||||||||||
84 | Clean bathrooms; close toilet lid | ||||||||||||||||||||||||
85 | Clean kitchen, including backsplash | ||||||||||||||||||||||||
86 | All trash removed from property (inside and out) | ||||||||||||||||||||||||
87 | Herbie empty and stored | ||||||||||||||||||||||||
88 | Exterior Doors: | ||||||||||||||||||||||||
89 | Anti-kick in plate installed; door stops installed | ||||||||||||||||||||||||
90 | Doors open/close/lock properly, don't stick, and are clean - no daylight around any doors | ||||||||||||||||||||||||
91 | Keys in lockbox ( all properties should always have 2 keys) | ||||||||||||||||||||||||
92 | Peephole installed no higher than 5' from floor | ||||||||||||||||||||||||
93 | Humidity control fan installed in crawl and attic, and is plugged in | ||||||||||||||||||||||||
94 | PHYSICALLY TOUCH AND MOVE/PULL items to make sure they are installed properly | ||||||||||||||||||||||||
95 | Exterior: | Pick up all trash | |||||||||||||||||||||||
96 | check skirting/siding | ||||||||||||||||||||||||
97 | make sure cleanouts are covered | ||||||||||||||||||||||||
98 | Gutters/downspouts are attached and divert water away from house | ||||||||||||||||||||||||
99 | Label keys for HVAC cage, and leave in lockbox near outside unit | ||||||||||||||||||||||||
100 | Using a metal or magnet sweep, clear area around house and parking area of nails/screws |