MT SOLAR GROUND MOUNT CALCULATOR
2
TO EDIT: click File/Make a copy...(Recommended)
OR: click File/Download as > Microsoft Excel
This is an open source project and for project estimation only.
Please email travis@mtsolar.us with any comments.
Any and all liablitiy resides with the user. Thank you for playing fair!
3
4
SITE VARIABLESQz=.00256*Kz*Kzt*Kd*V^2
F=Qh*G*Cf*As
PROJECT INFORMATIONDATE:2/8/2019
5
Module N/S Dimension (Round Up) (in.)66.0Customer:
6
Module E/W Dimension (Round Up) (in.)40.0Email Address:
7
Number of Modules Per Section24.04 PolesPhone Number:
8
Pole Spacing Desired (in.)13242 in. CantileverProject Name:
9
Desired Tilt Angle in Degrees50Project Address:
10
Wind Speed90VCity/State/ZIP:CO
11
Exposure CategoryBSolar Module:
12
Ground Clearance front edge of array (in.)12Solar Module Color:
13
Snow Load (PSF)10
NOT TO SCALE
14
Hole Size or Spade Plate Width Desired (in.)
8ROUND
15
Site Soil Classification Code3
Sandy Gravel
T Section
16
Vertical Beam SizeW6x9AUTO CALC
17
Minimum T Section SizeT-W6x9Defining Load
WIND
Array Center Height
18
Foundation Depth Required (ft.)7.50
Ft. DEEP
5.3 ft. Above Grade
19
Array Center Height Above Grade5.21Ft.
20
WIND FORCE CALCULATIONS (per Pole)
Min. Vert. Beam W6x9
Tilt 50 Degrees
21
Array N/S Dimensions (ft.)11.00ft
22
Per Pole E/W Dimensions (ft.)11.00ftB
12 in. ground clearance
23
Total Square Feet of Array per Pole121.00sq/ft
24
Tilt Angle in Radians 0.87
25
Effective Vert Dimension at Tilt Angle (ft.)8.43fts Concrete Per Pole
26
Effective Horizontal Dimension at Tilt Angle (ft.)
7.07ft 0.1 cu. yards.
8 in. Hole Size or Spade Width
27
Effective Squ Ft. at Tilt Angle92.69sq/ftAs
7.5 ft ground embedment
28
Total Array Height at Tilt Including Clearance (ft.)
9.43fth
29
Simple Wind PSF 20.74psf
30
Simple Wind Force Total 1,922.05lb/ft
31
Height/Exposure Coefficient ASCE 7-10 29.3-1
0.57Kz
32
Terrain Coefficient1.00Kzt
FOUNDATION DEPTH CALCULATIONS
33
Wind Directionality Factor ASCE 7-10 26.6-1
0.85KdForce at Top of Pole1,226.9lbs.Pe
34
Wind Force PSF (Qz)10.05lb/ftQzArray Center Height Above Grade5.2ftH
35
Gust Factor ASCE 7-10 26.9.10.85GSite Soil Lateral Bearing Capacity400psfPba
36
Ratio s/h0.89
Chart Row 0.71
Site Soil Vertical Bearing Capacity3,000psf
37
Ratio B/s1.31
Chart Column 1
Vertical Bearing Area of Hole0.35
squ. ft.
38
Force Coefficient Cf ASCE 7-10 29.4-11.55CfMax Vertical Bearing Capacity1,047lbs.
39
Effective Wind Load PSF13.24Hole Dimension0.67ft.b
40
Effective Wind Total Force Per Pole (Case A)
1,226.90FAllowable Lateral Soil Pressure666.67S1
41
Snow Load Total Vertical Force Per Pole (lbs.)
777.8Variable6.46A
42
TOTAL Force Per Pole Normal to Panels (lbs.)
1,439.8Foundation Depth Required (ft.)7.5ft.L
43
Copyright 2019 MT Solar LLC, All Rights Reserved.
Calculations based on ASCE 7-10 and IBC 2012