Parameter for rough computation of instantaneous heat transfer -- M:1.092
3
One version of heat transfer is calculated as M * (TS - TR) * FCFM ) -- the difference between supply and return temperatures multiplied by the airflow multiplied by the constant M.
4
The constant M combines factors for the density and specific heat of moist air and scales to an hourly rate for each minute (must divide by 60 after averaging rates)
5
Alternatively, we can use ASHRAE Moist air property functions for more complex computation that turns out to yield the same result.
6
See this post for explanation.
7
8
Period start11/7/2023 0:00:00
9
Period end3/14/2024 23:59:00
10
11
12
13
Upstairs input assumptions
14
Baseline flow estimate for upstairs unit (CFM)575
15
Fan watts at baseline102
16
17
Upstairs Results
18
Total minutes in time range185700
19
Minutes compressor active (see note 2) -- include these minutes in COP if have temps323210
20
% of time active17%
21
Average hours per 24 hours4.2
22
System active power use -- compressor (kwh)964
23
System active power use -- fan (kwh)51
24
Compressor standby power use (kwh)106
25
Fan standby power use108.2
26
Total minutes for which have both supply and return temperature122968
27
Active minutes for which have both supply and return temperature21933
28
Max temp split47.4
29
Average temp split while active24.0
30
Total BTU produced (active and have temp), using M factor above5407739.7
31
Total BTU heat converted to KWH1584.9
32
Corr. system power -- only while temp avail all compressor plus fan while active658.4
33
COP over season reported (including compressor standby but not fan standby)2.4
34
COP over season reported (excluding all standby)2.69
35
36
37
38
39
Memo: ASHRAE Properties Library computed average values
40
Return Air W (moisture content)0.0000
41
Supply Air W (moisture content)0.0000
42
Return Air Density0.0000
43
Return Air Specific Heat0.0000
44
45
Memo: Total heat produced estimate
46
Total compressor kwh while active964
47
Total therms heat produced 88
48
Check val: Number of zero value compressor minutes12698
49
50
51
52
Compressor heating threshold60
53
Fan on threshold2
54
55
56
57
58
59
60
61
62
63
64
65
66
Conversions
67
BTU to kwh -- 1/34120.0002930832356
68
So, pound force per newton4.448221909
69
Inches2 per meter 21550.0031
70
PSI/millibar0.01450377281
71
72
73
74
Notes on time consistency:
75
The power sheets use time from Emporia downloads which shows EDST until November 5 at 2AM, then falls back (line 24963) and repeats.
76
The power sheets return to EDST on March 10 at 2AM, dropping the 2AM hour (line 206462).
77
Total time period, Nov 7, 00:00 EST to March 14, 23:59 EDST. Predicted row checks:185701129Days
78
For the TRH logging:
79
Govee is all EST
80
Hobo download from gateway is all EDST
81
Hobo data loggers transition back to EDST skipping an hour like Emporia
82
Shifted from Gateway use to direct download from loggers on December 25 (see log line # on TRH sheets)
83
Missing Temp data is BLANK -- after interpolation, only gap is supply temp upstairs from 12/31 to 2/13
84
Logan data is GMT with appropriate shifts for matching to Emporia rows, Row count checks.3098
85
(Note that have extra row to match values that round to the missing EST to EDST hour.)
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100