ABCDEFGHIJKLMNOPQRSTUVWXYZAAAB
1
Key
2
WireFerruleDeviceWire ColourFerrule ColourDevice ColourDescription
3
IFM Sensor Cablebrownblackblackdevice power (+24VDC)
4
blueblackdevice ground (-)
5
blackblackoutput 1
6
whiteblackoutput 2
7
Clippard Valve (2.1mm x 5.5mm female)redyellowyellowETC-48 Cable valve coil lead
8
blackyellowETC-48 Cable valve coil lead
9
Clippard Valve LED indicatorredyellowyellowindicates valve open (+24VDC)
10
blackyellowindicates valve open (ground)
11
+24VDC Power (2.1mm x 5.5mm female)redredredcenter positive (+24VDC)
12
blackredpower ground (-)
13
Float Switch (2.1mm x 5.5mm female)redbluebluefloat switch port
14
blackbluefloat switch port
15
Feed Pump (2.1mm x 5.5mm female)redgreengreenfeed pump port + (optional Masterflex contact - terminal 11 on GR8-116)
16
blackgreenfeed pump port - (optional Masterflex contact - terminal 14 on GRB-116)
17
Manual vent switch (LED lit)yellowwhitewhiteIFM sensor output 1 connection (optional Auto Venting - terminal 11 on GR8-116)
18
redbluefloat switch connection (optional Auto Venting - terminal 12 on GR8-116)
19
blackwhiteManual vent switch LED indicator ground
20
3-Way Valve (2.1mm x 5.5mm female)redwhitewhite3-Way valve port coil (optional auto venting), for Apex control connect to terminal A1 of GR8-116
21
blackwhite3-Way valve port coil (optional auto venting), for Apex control connect to terminal A3 of GR8-116
22
24V Digital Timer (Optional auto venting)yellowredwhiteTerminal 1 Digital Timer +24VDC
23
blueredTerminal 2 Digital Timer ground (-)
24
yellowredConnects timer COM port to +24VDC
25
greenwhiteConnects timer NO port to fan out terminals (provides 24VDC to internal relay and Vent port)
26
GR8-116 (Optional Auto Venting)yellowredwhiteTerminal A1 Gaeyaele GR8-116 24VDC Relay coil - connects to timer NO port through terminal fan out
27
blueredTerminal A3 Gaeyaele GR8-116 24VDC Relay coil - connects to ground (-)
28
Venting jumper wiresyellowwhitewhiteTerminal 11 Gaeyaele GR8-116 24VDC Relay - replaces vent switch in terminal block
29
redblueTerminal 12 Gaeyaele GR8-116 24VDC Relay - replaces vent switch in terminal block
30
GR8-116 (Optional Masterflex control)redgreengreenTerminal A1 Gaeyaele GR8-116 24VDC Relay coil - connects to sensor Output 2
31
blackgreenTerminal A3 Gaeyaele GR8-116 24VDC Relay coil - connects to ground (-)
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100