A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Start Date | End Date | Headline | Text | Media | Media Credit | Media Caption | Media Thumbnail | Type | Tag | ||||||||||
2 | 3/11/2011 14:46:00 | 3/11/2011 14:46:00 | Unit 2 Fukushima Daiichi Timeline | Timeline of technical events at Unit 2 | SimplyInfo.Org | <a href="http://www.simplyinfo.org" title="Visit the site">SimplyInfo Website</a> | title | |||||||||||||
3 | 3/11/2011 14:46:01 | 3/11/2011 14:46:01 | Earthquake | Reactor scrammed | http://earthquake-report.com/wp-content/uploads/2011/03/honshu-11-03-2011.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
4 | 3/11/2011 14:47:00 | 3/11/2011 14:47:00 | Loss Of Offsite Power | Loss of all off site power | http://farm9.staticflickr.com/8100/8657451159_ef4dc5d398_o.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
5 | 3/11/2011 14:47:01 | 3/11/2011 14:47:01 | Reactor Scram | All control rods fully inserted | http://farm9.staticflickr.com/8519/8676175586_5dc99e2067_o.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
6 | 3/11/2011 14:47:02 | 3/11/2011 14:47:02 | Emergency Diesel Generator 2 Starts | Emergency Diesel EDG2 starts automatically | http://photo.tepco.co.jp/library/130306_01/130306_01.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
7 | 3/11/2011 14:47:03 | 3/11/2011 14:47:03 | Emergency Diesel Generator 1 Starts | Emergency Diesel EDG1 starts automatically | http://photo.tepco.co.jp/library/130306_01/130306_01.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
8 | 3/11/2011 14:47:04 | 3/11/2011 14:47:04 | MSIV Closed | MSIV's Main Steam Isolation Valves fail in the closed position -normally open | http://farm9.staticflickr.com/8124/8657416263_47f34dec52_o.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
9 | 3/11/2011 14:50:00 | 3/11/2011 14:50:00 | RCIC Manually Started | Operators start RCIC | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
10 | 3/11/2011 14:51:00 | 3/11/2011 14:51:00 | RCIC Automatically Shutdown | RCIC Auto shutdown due to high RPV water level | http://farm9.staticflickr.com/8125/8660176913_2f57cf8e1c_o.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
11 | 3/11/2011 14:52:00 | 3/11/2011 14:52:00 | SRV Controlling Pressure Automatically | SRV's in auto, controlling reactor vessel pressure | http://farm9.staticflickr.com/8126/8657436885_3d2b6001c9_o.jpg | INPO | <a href="http://nas-sites.org/fukushima/files/2012/08/INPO-Meng-August-2012-NAS-FINAL.pdf" title="Visit the site">INPO</a> | |||||||||||||
12 | 3/11/2011 15:00:00 | 3/11/2011 15:00:00 | RHR Starts Wetwell Cooling | RHR system cooling wetwell, aka torus or suppression chamber | http://farm9.staticflickr.com/8385/8674815641_38af1fd5e3_o.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
13 | 3/11/2011 15:02:00 | 3/11/2011 15:02:00 | RCIC Manually Started | Operators start RCIC | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
14 | 3/11/2011 15:07:00 | 3/11/2011 15:07:00 | RHR Stopped | RHR system cooling of wetwell torus stops | https://farm9.staticflickr.com/8385/8674815641_66e879ff55_n.jpg | JNTI | http://www.gengikyo.jp/english/shokai/Tohoku_Jishin/report.pdf | |||||||||||||
15 | 3/11/2011 15:25:00 | 3/11/2011 15:25:00 | Torus Spray Started | Operators start torus suppression chamber spray cooling | https://farm8.staticflickr.com/7391/16374507649_e27472527b_n.jpg | INPO | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
16 | 3/11/2011 15:27:00 | 3/11/2011 15:27:00 | 1st Tsunami Wave | 1st tsunami wave hits the plant | http://farm9.staticflickr.com/8119/8657415885_dd3e0981db_o.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||
17 | 3/11/2011 15:28:00 | 3/11/2011 15:28:00 | RCIC Stops | RCIC stops | http://farm9.staticflickr.com/8125/8660176913_2f57cf8e1c_o.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
18 | 3/11/2011 15:31:00 | 3/11/2011 15:31:00 | HPCI Inoperable | HPCI inoperable due to no DC power | https://farm9.staticflickr.com/8120/8658465390_5287e422b2_n.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
19 | 3/11/2011 15:35:00 | 3/11/2011 15:35:00 | 2nd Tsunami Wave | 2nd tsunami wave hits the plant | http://farm9.staticflickr.com/8119/8657415885_dd3e0981db_o.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||
20 | 3/11/2011 15:36:00 | 3/11/2011 15:36:00 | RHR Stops | RHR stops | http://farm9.staticflickr.com/8534/8675062483_1f56151747.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
21 | 3/11/2011 15:39:00 | 3/11/2011 15:39:00 | RCIC Starts | RCIC starts manually | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
22 | 3/11/2011 15:41:00 | 3/11/2011 15:41:00 | Station Blackout | Total loss of power (Including DC) | http://farm9.staticflickr.com/8100/8657451159_ef4dc5d398_o.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
23 | 3/11/2011 15:41:01 | 3/11/2011 15:41:01 | HPCI Failed To Start | High Pressure Coolant Injection fails to start due to loss of dc power | http://farm9.staticflickr.com/8099/8591868991_27ec6658e4.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
24 | 3/11/2011 15:41:02 | 3/11/2011 15:41:02 | RHR Service Water Fails | RHR service water fails to operate | http://farm9.staticflickr.com/8534/8675062483_1f56151747.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
25 | 3/11/2011 15:41:03 | 3/11/2011 15:41:03 | Multiple System Failures From Tsunami | Diesel generators 2A and 2B both fail. 2B fails due to power panel failure. Power panels flooded by tsunami taking out power distribution, loss of instrumentation, loss of monitoring for HPCI and RCIC, loss of normal and emergency lighting, | https://farm9.staticflickr.com/8659/16375131309_59448ecde2_o.jpg | INPO | <a href="https://www.dropbox.com/s/qqrx7u04a5mo0ut/INPO%2011_005_Special_Report_on_Fukushima_Daiichi_MASTER_11_08_11_1.pdf?dl=0" title="Visit the site">INPO</a> | |||||||||||||
26 | 3/11/2011 15:50:00 | 3/11/2011 15:50:00 | Loss Of Instrument Function | Power to measuring instruments lost including water level and drywell pressure | JNTI | <a href="http://www.gengikyo.jp/english/shokai/Tohoku_Jishin/report.pdf" title="Visit the site">JNTI</a> | ||||||||||||||
27 | 3/11/2011 16:02:00 | 3/11/2011 16:02:00 | RCIC off | RCIC tripped on high RPV water level | http://farm9.staticflickr.com/8125/8660176913_2f57cf8e1c_o.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
28 | 3/11/2011 16:03:00 | 3/11/2011 16:03:00 | RCIC started manually | RCIC started manually | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
29 | 3/11/2011 16:36:00 | 3/11/2011 16:36:00 | Can't Read Reactor Water Level | Among other instruments lost, reactor water level can't be read. Batteries and cables are brought in to try to power instruments to read them. | INPO | <a href="https://www.dropbox.com/s/qqrx7u04a5mo0ut/INPO%2011_005_Special_Report_on_Fukushima_Daiichi_MASTER_11_08_11_1.pdf?dl=0" title="Visit the site">INPO</a> | ||||||||||||||
30 | 3/11/2011 17:12:00 | 3/11/2011 17:12:00 | Plan Considered To Inject Water By RHR | Workers considered using the RHR system to connect into and inject water to the reactor via fire truck | http://farm9.staticflickr.com/8385/8674815641_38af1fd5e3_o.jpg | INPO | <a href="https://www.dropbox.com/s/qqrx7u04a5mo0ut/INPO%2011_005_Special_Report_on_Fukushima_Daiichi_MASTER_11_08_11_1.pdf?dl=0" title="Visit the site">INPO</a> | |||||||||||||
31 | 3/11/2011 20:07:00 | 3/11/2011 20:07:00 | RPV Pressure 7000 | RPV pressure instrument read at 7000 | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
32 | 3/11/2011 20:49:00 | 3/11/2011 20:49:00 | Temporary Lighting | Temporary lighting to the main control room working | http://farm8.staticflickr.com/7248/7072335835_ff82cae871.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
33 | 3/11/2011 21:02:00 | 3/11/2011 21:02:00 | Water At Top Of Fuel | Water level may have dropped to top of fuel assemblies | http://farm9.staticflickr.com/8110/8659549172_b3c5b05398_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
34 | 3/11/2011 21:30:00 | 3/11/2011 21:30:00 | Workers Run Power Cables | Workers begin running cabling to power SLC pumps | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | ||||||||||||||
35 | 3/11/2011 21:50:00 | 3/11/2011 21:50:00 | Water level 3400 mm | Reactor water level readout restored in main control room, water is 3400mm above the top of the fuel assemblies | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
36 | 3/11/2011 22:00:00 | 3/11/2011 22:00:00 | RCIC operation can't be confirmed | Operation of the RCIC can't be confirmed | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
37 | 3/11/2011 23:25:00 | 3/11/2011 23:25:00 | Drywell Pressure | DW pressure readout restored, pressure readings of 20 PSIA, 9.141 mPa | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
38 | 3/11/2011 23:25:01 | 3/11/2011 23:25:01 | RPV Pressure 6300 | RPV Pressure instrument restored, read at 6300 (6.3 mpa) | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
39 | 3/11/2011 23:54:00 | 3/11/2011 23:54:00 | Drywell Pressure 40 mpa | Drywell Pressure 40 mpa | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
40 | 3/12/2011 1:30:00 | 3/12/2011 1:30:00 | RPV Pressure 5300, Drywell .151 abs | RPV Pressure 5300, Drywell .151 abs | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
41 | 3/12/2011 2:50:00 | 3/12/2011 2:50:00 | RPV Pressure 5600 | RPV Pressure instrument read at 5600 | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
42 | 3/12/2011 2:55:00 | 3/12/2011 2:55:00 | RCIC Function Confirmed | Workers confirm the function of the RCIC. Wearing breathing protection and boots, workers attempted to verify the condition of RCIC. 10 minutes of work took an hour. Water level in RCIC room was up to workers boots. Could hear faint metallic sounds and assume this is the RCIC operating. Second attempt to check RCIC, room had more water. RCIC exit pump pressure was checked on an instrument rack | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | TEPCO, INPO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
43 | 3/12/2011 3:15:00 | 3/12/2011 3:15:00 | Drywell Pressure .161 abs | Drywell pressure read at .161 abs | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
44 | 3/12/2011 3:58:00 | 3/12/2011 3:58:00 | Aftershock | Aftershock at the plant | http://www.fukuleaks.org/web/wp-content/uploads/2015/02/japanquake-150x150.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
45 | 3/12/2011 4:20:00 | 3/12/2011 4:20:00 | RCIC Suction In Wetwell | RCIC now drawing water off the wetwell aka torus or suppression chamber | http://3.bp.blogspot.com/-mRp0dDxr2_o/TgoqewpX9TI/AAAAAAAAAUw/8n1EwlGXjbs/s1600/rcic_pump.jpg | SNL | <a href="http://energy.sandia.gov/wp/wp-content/gallery/uploads/Fukushima_SAND2012-6173.pdf" title="Visit the site">SNL</a> | |||||||||||||
46 | 3/12/2011 8:46:00 | 3/12/2011 8:46:00 | Reactor Water Level 3600 | Reactor water level 3600, RPV pressure 6000, Drywell pressure .186 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
47 | 3/12/2011 12:55:00 | 3/12/2011 12:55:00 | Reactor Water Level 3600 | Reactor water level 3600. RPV pressure 6100, Drywell pressure .211 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
48 | 3/12/2011 15:22:00 | 3/12/2011 15:22:00 | Reactor Water Level 3600 | Reactor water level 3600, RPV pressure 6300, Drywell pressure .231 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
49 | 3/12/2011 15:36:00 | 3/12/2011 15:36:00 | Aftershock | Aftershock at the plant, Unit 1 explosion at the same time | https://farm8.staticflickr.com/7438/16562936751_7733026baa_n.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
50 | 3/12/2011 15:37:00 | 3/12/2011 15:37:00 | Reactor Water Level Drops to 3550 | Reactor water level drops for first time down to 3550 | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
51 | 3/12/2011 17:30:00 | 3/12/2011 17:30:00 | Preparations To Vent | Plant manager gives order to vent reactor. Media reports "some steam" released | http://farm9.staticflickr.com/8351/8335279600_820e862a96_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
52 | 3/12/2011 18:20:00 | 3/12/2011 18:20:00 | RPV Pressure 3600 | RPV pressure 3600, Drywell pressure .256 abs | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
53 | 3/12/2011 20:05:00 | 3/12/2011 20:05:00 | Effort to restore power abandoned | Workers ordered to anti-seismic building after unit 1 explodes | https://farm8.staticflickr.com/7258/7072236665_d8abbe1d00_o.jpg | TEPCO | <a href="http://www.tepco.co.jp/en/nu/fukushima-np/plant-data/f1_7_Sousajisseki_20110717.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
54 | 3/13/2011 3:00:00 | 3/13/2011 3:00:00 | Reactor Water 3650 | Reactor water 3650, RPV pressure 6.098 Drywell pressure .315 abs *ANS notes the slow rise of drywell pressure here could incidate a leak | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
55 | 3/13/2011 8:00:00 | 3/13/2011 8:00:00 | Reactor Water 3650 | Reactor water 3650, RPV pressure 6.100, Drywell pressure .350 | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
56 | 3/13/2011 8:10:00 | 3/13/2011 8:10:00 | Containment Vent Open | PCV containment vent valve open. *ANS notes the MOV was opened 25%. INPO cites vent valve MO-271 was opened | http://farm9.staticflickr.com/8351/8335279600_820e862a96_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
57 | 3/13/2011 9:25:00 | 3/13/2011 9:25:00 | Reactor Water 3700 | Reactor water 3700, RPV pressure 6.080, Drywell pressure .365 abs | http://farm6.staticflickr.com/5280/6926257642_0008178346.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
58 | 3/13/2011 9:55:00 | 3/13/2011 9:55:00 | Reactor Water 3700 | Reactor water 3700, RPV pressure 1.283, Drywell pressure .160 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
59 | 3/13/2011 10:15:00 | 3/13/2011 10:15:00 | Additional Valve Opened | Workers used the small generator in the control room, which had been installed to restore some lighting, to energize the solenoid for the large air-operated suppression chamber vent valve AO-205 | INPO | <a href="https://www.dropbox.com/s/qqrx7u04a5mo0ut/INPO%2011_005_Special_Report_on_Fukushima_Daiichi_MASTER_11_08_11_1.pdf?dl=0" title="Visit the site">INPO</a> | ||||||||||||||
60 | 3/13/2011 11:00:00 | 3/13/2011 11:00:00 | Venting Ready Except Rupture Disc | Venting prepared except rupture disc | http://farm9.staticflickr.com/8351/8335279600_820e862a96_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
61 | 3/13/2011 11:20:00 | 3/13/2011 11:20:00 | Venting Commenced | Venting commenced | http://farm9.staticflickr.com/8351/8335279600_820e862a96_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
62 | 3/13/2011 11:35:00 | 3/13/2011 11:35:00 | Reactor Water 3700 | Reactor water 3700, Drywell pressure .380 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
63 | 3/13/2011 12:05:00 | 3/13/2011 12:05:00 | Prepare To Use Seawater | Plant manager gives order to prepare to inject sea water into the reactor | http://farm9.staticflickr.com/8125/8659623360_5c84d6def3_z.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
64 | 3/13/2011 13:52:00 | 3/13/2011 13:52:00 | Radiation Increase | 1557.5 μSv/h at MP4 | https://farm8.staticflickr.com/7489/16020015252_b3cb7a2afd_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
65 | 3/13/2011 14:15:00 | 3/13/2011 14:15:00 | Reactor Water 3750 | Reactor water 3750, Drywell pressure .390 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
66 | 3/13/2011 14:45:00 | 3/13/2011 14:45:00 | Reactor Water 3750 | Reactor water 3750, Drywell pressure .395 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
67 | 3/13/2011 15:30:00 | 3/13/2011 15:30:00 | Reactor Water 3750 | Reactor water 3750, RPV pressure 5.850, Drywell pressure .400 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
68 | 3/13/2011 22:00:00 | 3/13/2011 22:00:00 | Reactor Water 3900 | Reactor water 3900 Drywell pressure .430 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
69 | 3/13/2011 23:59:00 | 3/13/2011 23:59:00 | Reactor Water 3900 | Reactor water 3900 Drywell pressure .435 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
70 | 3/14/2011 0:05:00 | 3/14/2011 0:05:00 | Preparation For Seawater Injection | Plant manager orders preparation for seawater injection | http://farm9.staticflickr.com/8125/8659623360_5c84d6def3_z.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
71 | 3/14/2011 1:30:00 | 3/14/2011 1:30:00 | Reactor Water 3900 | Reactor water 3900, Drywell pressure .440 abs | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
72 | 3/14/2011 1:40:00 | 3/14/2011 1:40:00 | NISA cites problem with injecting water at unit 2 | TEPCO headquarters official handling contact with government ministries and agencies began speaking with these words: “We’ve got something urgent.” It was about NISA’s repeated instruction to inject water into the No. 2 reactor. The RCIC would soon no longer work. NISA officials wanted TEPCO to switch as soon as possible to the injection of water from outside sources. There arose a serious obstacle to letting that happen: There was little seawater available nearby in pools, and the fire engine pumps at the plant were incapable of pumping seawater from the ocean because they had insufficient power to lift water over the 10-meter elevation from sea level. | https://farm9.staticflickr.com/8648/16378457049_8bcf71fa20_n.jpg | Main Timeline | <a href="http://www.fukuleaks.org/web/?page_id=7419" title="Visit the site">SimplyInfo.org Main Daiichi Timeline</a> | |||||||||||||
73 | 3/14/2011 3:05:00 | 3/14/2011 3:05:00 | Problem with TEPCO contract fire fighters | Contracted fire crews from Nanmei Kosan expressed concerns over the rising radiation levels. TEPCO debated telling them there was no risk, ended up having Nanmei Kosan's office demand the workers stay. | https://farm6.staticflickr.com/5191/6948992456_5fe8fb00e9_n.jpg | Main Timeline | <a href="http://www.fukuleaks.org/web/?page_id=7419" title="Visit the site">SimplyInfo.org Main Daiichi Timeline</a> | |||||||||||||
74 | 3/14/2011 4:30:00 | 3/14/2011 4:30:00 | Reactor Water 3900 | Reactor water 3900, RPV pressure 5.400, S/C pressure .467 | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
75 | 3/14/2011 6:00:00 | 3/14/2011 6:00:00 | CAMS Radiation Readings | Drywell CAMS 1.00E-03 SC CAMS 9.00E-03 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
76 | 3/14/2011 7:45:00 | 3/14/2011 7:45:00 | CAMS Radiation Readings | Drywell CAMS 1.00E-03 SC CAMS 9.50E-03 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
77 | 3/14/2011 8:00:00 | 3/14/2011 8:00:00 | CAMS Radiation Readings | Drywell CAMS 1.00E-03 SC CAMS 1.00E-02 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
78 | 3/14/2011 9:34:00 | 3/14/2011 9:34:00 | Unsure if SC vent opened | Could not confirm SC vent open or not at the time | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | ||||||||||||||
79 | 3/14/2011 9:37:00 | 3/14/2011 9:37:00 | Radiation Increase | 3130.0 μSv/h at Main Gate | https://farm8.staticflickr.com/7432/16378855087_df61e243d0_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
80 | 3/14/2011 9:45:00 | 3/14/2011 9:45:00 | CAMS Radiation Readings | Drywell CAMS 1.00E-03 SC CAMS 1.20E-02 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
81 | 3/14/2011 10:15:00 | 3/14/2011 10:15:00 | CAMS Radiation Readings | Drywell CAMS 1.00E-03 SC CAMS 9.70E-03 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
82 | 3/14/2011 11:01:00 | 3/14/2011 11:01:00 | Unit 3 Explodes | Unit 3 explodes | https://farm8.staticflickr.com/7414/15945068883_9852e1a543_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
83 | 3/14/2011 11:01:01 | 3/14/2011 11:01:01 | Torus Valve Damaged | Venting valve to torus suppression chamber damaged by unit 3 explosion. Is now closed. Vent valve AO-205 | TEPCO, INPO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | ||||||||||||||
84 | 3/14/2011 11:01:02 | 3/14/2011 11:01:02 | Fire Engine & Injection Line Damaged | Fire engine and water injection line damaged by unit 3 explosion | http://farm9.staticflickr.com/8125/8659623360_5c84d6def3_z.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
85 | 3/14/2011 11:01:03 | 3/14/2011 11:01:03 | Torus vent pipe damaged | The valves’ closed status and inability to be opened confirmed | TEPCO | <a href="http://www.tepco.co.jp/en/nu/fukushima-np/plant-data/f1_7_Sousajisseki_20110717.pdf" title="Visit the site">TEPCO</a> | ||||||||||||||
86 | 3/14/2011 11:30:00 | 3/14/2011 11:30:00 | CAMS Radiation Readings | Drywell 1.00E-03, SC 1.20E-02 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
87 | 3/14/2011 12:00:00 | 3/14/2011 12:00:00 | SC temps and water level | Suppression Chamber temp 147c, pressure 485 kpa, water level decreasing | https://farm8.staticflickr.com/7391/16374507649_e27472527b_n.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
88 | 3/14/2011 12:30:00 | 3/14/2011 12:30:00 | RPV water level 2950mm | * doesn't say if this is above or below fuel, assumed above | http://farm8.staticflickr.com/7363/8715246204_9d93df8c83.jpg | ANS | <a href="http://fukushima.ans.org/inc/Fukushima_Appendix_H.pdf" title="Visit the site">ANS</a> | |||||||||||||
89 | 3/14/2011 13:00:00 | 3/14/2011 13:00:00 | TEPCO communication With Daiichi | Yoshida asks TEPCO HQ over concerns of hydrogen build up in unit 2 “I want you to think of ways to open a hole in the reactor building immediately by using helicopters or whatever.“ | http://www.fukuleaks.org/web/wp-content/uploads/2014/05/2013-07-06_masao-yoshida-ancien-directeur-Fukushima.jpg | Main Timeline | <a href="http://www.fukuleaks.org/web/?page_id=7419" title="Visit the site">SimplyInfo.org Main Daiichi Timeline</a> | |||||||||||||
90 | 3/14/2011 13:05:00 | 3/14/2011 13:05:00 | Reconnection Of Fire Line | Work starts to reconnect water injection fire line. Workers switched to using the harbor to pull sea water after unit 3 exploded. Previous work used the backwash valve pit by unit 3. It was now high in radiation and debris. | http://farm9.staticflickr.com/8125/8659623360_5c84d6def3_z.jpg | TEPCO, INPO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
91 | 3/14/2011 13:18:00 | 3/14/2011 13:18:00 | Reactor Water Dropping | Reactor water level on downward trend | http://farm9.staticflickr.com/8122/8676039680_d8103f69c9.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
92 | 3/14/2011 13:25:00 | 3/14/2011 13:25:00 | RCIC Failure | RCIC appears to be lost (at time of trip, indicated water level was approx 95 inches (2400mm) above (top of fuel) TAF, drywell pressure 67 psi (465 kPa) | http://farm9.staticflickr.com/8125/8660176913_2f57cf8e1c_o.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
93 | 3/14/2011 14:00:00 | 3/14/2011 14:00:00 | Suppression Pool Saturated | Suppression chamber reaches saturation point. Water at the point it can no longer quench steam or cool steam releases | https://farm8.staticflickr.com/7391/16374507649_e27472527b_n.jpg | WNA, INPO | <a href="http://www.world-nuclear.org" title="Visit the site">WNA</a> | |||||||||||||
94 | 3/14/2011 14:40:00 | 3/14/2011 14:40:00 | CAMS Radiation Readings | Drywell 1.00E-03, SC 1.30E-02 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
95 | 3/14/2011 15:15:00 | 3/14/2011 15:15:00 | CAMS Radiation Readings | Drywell 1.08E-03 SC 1.03E-02 | https://farm8.staticflickr.com/7405/15942497424_78e6a08bf7_n.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
96 | 3/14/2011 16:34:00 | 3/14/2011 16:34:00 | RPV depressurization SRV open | RPV depressurization SRV open * TEPCO admitted in 2015 that SRV nitrogen actuation lines fail at 170c temperatures rendering the valves unusable. | https://farm9.staticflickr.com/8662/16564288592_be9bc7d6a9_n.jpg | TEPCO | <a href="http://www.tepco.co.jp/en/nu/fukushima-np/plant-data/f1_7_Sousajisseki_20110717.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
97 | 3/14/2011 16:34:01 | 3/14/2011 16:34:01 | Seawater Injection Starts | Seawater injection using the firefighting line commenced. **2014 reports admit that all or most of this fire line injection water back flowed into the turbine building due to the lack of backflow valves in the piping. | https://farm9.staticflickr.com/8603/15945246293_5152c85271_n.jpg | TEPCO | <a href="http://www.tepco.co.jp/en/nu/fukushima-np/plant-data/f1_7_Sousajisseki_20110717.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
98 | 3/14/2011 16:45:00 | 3/14/2011 16:45:00 | Debate between Daiichi and TEPCO HQ | Confusion over ability to establish the venting line, HQ wanting water injected, apparently not understanding the need to vent. | https://farm9.staticflickr.com/8648/16378457049_8bcf71fa20_n.jpg | Main Timeline | <a href="http://www.fukuleaks.org/web/?page_id=7419" title="Visit the site">SimplyInfo.org Main Daiichi Timeline</a> | |||||||||||||
99 | 3/14/2011 17:17:00 | 3/14/2011 17:17:00 | Water Level Falls To Top Of Fuel | Water in the reactor falls to top of fuel assemblies | http://farm9.staticflickr.com/8103/8674938681_9423c9953a.jpg | TEPCO | <a href="http://www.simplyinfo.org/wp-content/uploads/2013/03/TEPCOtimeline110618e15-1.pdf" title="Visit the site">TEPCO</a> | |||||||||||||
100 | 3/14/2011 18:02:00 | 3/14/2011 18:02:00 | Pressure Decrease, SRV 2 Opened Again | Reactor pressure decrease confirmed SRV2 valve opened to resume depressurization due to insufficient reactor pressure decrease * ANS cites SRVs have no air pressure or voltage at this point *** TEPCO admitted in 2015 that SRV nitrogen actuation lines fail at 170c temperatures rendering the valves unusable. | https://farm9.staticflickr.com/8662/16564288592_be9bc7d6a9_n.jpg | TEPCO | <a href="http://www.tepco.co.jp/en/nu/fukushima-np/plant-data/f1_7_Sousajisseki_20110717.pdf" title="Visit the site">TEPCO</a> |