ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Project name:1
2
Client:2
3
Address:3
4
Project locaton:4
5
6
General Data:
7
Total length of the building, L =
90ft27432mm27.432meter
8
Total width of the building or span of gable, B =
42ft12801mm12.801meter
9
Bayspacing or spacing of rafter =
18ft5486mm5.486meter
10
Eave height of the building, HE =
16ft4876mm4.876meter
11
Ridge height of the building, HR =
20.5ft6248mm6.248meter
12
13
Solution:
14
Sustained wind pressur, qz = CcCICzVb2
15
1) Basic wind speed from BNBC, Vb =
210kmph130mph
16
2) Structure importance coefficient, CI =
1
(Table 6.2.9, page-6-33)
17
3) Velocity -to-pressure conversion coefficient, Cc =
0.0000472
(Page-6-33)
18
4) Terrain exposure category =
A
19
Interpolation
20
Eexposure coefficient, Cz and sustained wind pressure, qz:
(Table 6.2.10, page-6-33)
At eaveAt h
21
C4.5( 0-15 ft)0.368qz =0.766kN/m200
22
C6(20 ft)0.415qz =0.864kN/m20.79056533330.8355146667
23
C9 (30 ft)0.497qz =1.035kN/m200
24
C12(40 ft)0.565qz =1.176kN/m200
25
C15(50 ft)0.624qz =1.299kN/m200
26
C18(60 ft)0.677qz =1.409kN/m200
27
28
5) Gust response factor, CG :
(Table 6.2.11, page-6-36)
29
CG4.5 (0-15 ft)1.6540
30
CG6 (20 ft)1.5921.610021333
31
CG9 (30 ft)1.5110
32
CG12 (40 ft)1.4570
33
CG15 (50 ft)1.4180
34
CG18 (60 ft)1.3880
35
36
Average height of the gable, h =
18.25ft5.564meter
37
At eave height of the gable frame, qhe =
0.791kN/m2
38
For total height or average of gable frame, qh =
0.836kN/m2
39
Gust response factor at total or average height, CGh =
1.61
40
41
6) Internal peak pressure coefficient, C'pi =
60.25
42
Hence internal pressure or internal suction = C'piqh =
0.209kN/m2
43
44
7) External pressure coefficient Cpe for walls:
45
a) For transverse wind:
B/L =0.47
46
47
Lower value of B/L =
0.1 Cpe =-0.5
48
Higher value of B/L =
0.65 Cpe =-0.6
49
50
Windward wall, Cpe =
0.8
(Figure 6.2.5, page-6-40)
51
Leeward wall, Cpe =
-0.57
(Interpolated value)
52
Side or End walls, Cpe =
-0.7
53
54
h/B =0.43and u12.095degree
55
56
For u10and u20degree
57
Lower value of h/B =
0.3Cpe =0.2Cpe =0.20.2
58
Higher value of h/B =
0.5Cpe =-0.9Cpe =-0.75-0.87
59
60
Windward roof, Cpe =
-0.5
61
Leeward roof, Cpe =
-0.7
62
63
8) Design pressure for external forces plus internal suction, p = qzCGhCpe+C'piqh
64
Windward wall:0-15 ftp =1.196kN/m20.45klf
65
15~20 ftp =1.322kN/m20.497klf
66
20~30 ftp =1.542kN/m20.58klf
67
30~40 ftp =1.724kN/m20.648klf
68
40~50 ftp =1.882kN/m20.708klf
69
50~60 ftp =2.024kN/m20.761klf
70
71
Windward roof:p =-0.464kN/m2-0.174klf
72
Leeward roof:p =-0.733kN/m2-0.276klf
73
Leeward wall:p =-0.517kN/m2-0.194klf
74
Side or End walls:p =-0.682kN/m2-0.256klf
75
76
9) Design pressure for external forces plus internal pressure, p = qzCGhCpe-C'piqh
77
Windward wall:0-15 ftp =0.778kN/m20.292klf
78
15~20 ftp =0.904kN/m20.34klf
79
20~30 ftp =1.124kN/m20.423klf
80
30~40 ftp =1.306kN/m20.491klf
81
40~50 ftp =1.464kN/m20.55klf
82
50~60 ftp =1.606kN/m20.604klf
83
84
Windward roof:p =-0.882kN/m2-0.332klf
85
Leeward roof:p =-1.151kN/m2-0.433klf
86
Leeward wall:p =-0.935kN/m2-0.351klf
87
Side or End walls:p =-1.1kN/m2-0.414klf
88
89
90
91
92
93
94
95
96
97
98
99
100