ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
2
Bullet V1 / V1.5Bullet V2Explanation
3
Error Name from source code
RT1 Hex error
RT2 Decimal
ValueValue
4
ERROR_INDUCTION_SENDPOWERCOMMAND 0x010x0110 = timeout,
Control board could not communicate with the induction board and set the power. Maybe wiring harness issue
5
ERROR_INDUCTION_READINDUCTIONREGISTERS1 0x020x022
6
ERROR_INDUCTION_SENDPOWERCOMMAND_TIMEOUT 0x030x033
7
ERROR_INDUCTION_READINDUCTIONREGISTERS_HAL_I2C_GETSTATE_TIMEOUT0x044
8
ERROR_INDUCTION_SENDPOWERCOMMAND_POWERLIMIT 0x050x055
9
ERROR_INDUCTION_READINDUCTIONREGISTERS2 0x060x066Internal error code
Control board could not communicate with the induction board and read the values. Maybe wiring harness issue
10
ERROR_INDUCTION_READINDUCTIONREGISTERS3 0x070x077
11
ERROR_SAFETYCHECKS_NONCRITICALCHECK_BLOWERFAN_RPM_TOO_HIGH_DIRTY_OR_FORCED_AIRFLOW_BIT
0x088
12
ERROR_INDUCTION_TIMEOUT 0x090x099
13
value for above ERROR_INDUCTION_TIMEOUT_1 0x00010x0011
14
15
ERROR_INDUCTION_OTHER_ERROR 0x0a

*** NB ONLY V1 !
0x0a10
Induction status code:
1/129 N/A
2/130 IGBT Overcurrent detection
3/131 N/A
4/132 Output overload
5/133 Self-test error
6/134 Undervoltage
7/135 IGBT Overtemperature
8/136 Reel/Pot Overtemperature
9/137 N/A
10/138 Storage Error
11/139 Coil failure - Cannot be fixed. Need a new induction module
12/140 Output overcurrent
13/141 Driver error
14/142 NTC failure - Check the connection to the IGBT sensor
15/143 Communication error
16/144 Small distance between coil and pan
17/145 N/A
18/146 N/A
19/147 External fault
20/148 Overvoltage
21/149 Output coil interference
22/150 Cookware is too small
23 N/A
24 N/A
25 Coil temperature anomalies
16
17
18
IR / IBTS Connection Errors0x0b11related to ibts/infrared sensor
19
0x0c12related to ibts/infrared sensor
20
0x0d13related to ibts/infrared sensor
21
0x0e14related to ibts/infrared sensor
22
0x0f15related to ibts/infrared sensor
23
LED Controlboard Connection Errors0x1016related to the LED board
24
0x1117related to the LED board, cannot read data
25
0x1218
related to the LED board, cannot read the keys that you press
26
ERROR_INDUCTION_COMS_ERROR0x1420COMS Error. If only once should be OK
27
28
ERROR_SAFETYCHECKS_CHECKBLOWERRPM_STALLED 0x1f0x1f31Exhaust fan blocked
29
ERROR_SAFETYCHECKS_CHECKCOILFAN1SRPM_TOOLOW 0x200x2032Coil fan 1 low speed
30
ERROR_SAFETYCHECKS_CHECKCOILFAN1SRPM_STALLED 0x210x2133Coil fan 1 blocked
31
ERROR_SAFETYCHECKS_CHECKCOILFAN2SRPM_TOOLOW 0x220x2234Coil fan 2 low speed
32
ERROR_SAFETYCHECKS_CHECKCOILFAN2SRPM_STALLED 0x230x2335Small computer fan in the back is not spinningCoil fan 2 blocked
33
0x2436
34
0x2537
35
ERROR_SAFETYCHECKS_NONCRITICALCHECK_VINTOOLOW 0x260x2638Low net voltage
36
ERROR_SAFETYCHECKS_CRITICALCHECK_VINTOOHIGH 0x270x2739High net voltage
37
ERROR_SAFETYCHECKS_CRITICALCHECK_DRUMTEMPTOOHIGH 0x280x2840Drum temperature too high
38
ERROR_SAFETYCHECKS_CRITICALCHECK_BEANTEMPTOOHIGH 0x290x2941Beam probe temperature too high
39
ERROR_SAFETYCHECKS_CRITICALCHECK_IRAMBIENTTEMPTOOHIGH 0x2a0x2a42Temp of IR sensor casing
Temp of IR sensor casing
IBTS casing temperature too high
If using IBTS the micro fan might not be running.
40
ERROR_SAFETYCHECKS_CRITICALCHECK_PCBAMBIENTTEMPTOOHIGH 0x2b0x2b43Control PCB temperature too high
41
ERROR_SAFETYCHECKS_CRITICALCHECK_COILTEMPTOOHIGH 0x2c0x2c44Coil temperature too high
Temperature of IGBT. If very high maybe read error from board.
42
ERROR_SAFETYCHECKS_CRITICALCHECK_INTERACTIONNORESPONSE 0x2d0x2d45No user response error
43
ERROR_SAFETYCHECKS_CRITICALCHECK_IGBTTEMPTOOHIGH 0x2e0x2e46
Temperature of the IGBTs is too high.
Induction temperature too high
If roasting in high ambient temperature and running full power for a long timethis could happen.
44
ERROR_SAFETYCHECKS_CRITICALCHECK_IBTSFANRPMTOOLOW 0x2f0x2f47IBTS fan low speed
45
ERROR_SAFETYCHECKS_CRITICALCHECK_BEANTEMPTOOLOW 0x300x3048Under -1degree CBean probe temperature too low
46
ERROR_SAFETYCHECKS_CRITICALCHECK_BEANPROBEFAILURE 0x310x3149Under -40degree CBean probe failure
47
48
49
ERROR_MAINTENANCE_IR_GLASS_TOO_DIRTY 0x810x81129Order the IBTS
50
ERROR_INDUCTION_INIT 0x820x82130
51
ERROR_INDUCTION_CONTROL_ERROR0x83131
52
ERROR_INDUCTION_CONTROL_ERROR0x83131
Induction status code:
53
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_OC_ANALOGUE 0x01
54
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_OC_MEASURED 0x02
55
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_FREQ_TOO_HIGH 0x04
56
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_FREQ_TOO_LOW 0x08
57
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_TIMEOUT 0x10 /* When the inducti
58
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_ZERO_CROSSING 0x20
59
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_CURRENT 0x40
60
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_VLINK_TOO_HIGH 0x80 -128
61
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_VLINK_TOO_LOW 0x100 - 256
62
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_DRUM 0x200 - 512
63
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_ZERO_CROSSING_STARTUP 0x400
64
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_ZERO_CROSSING_VLINK_DETECT 0x800
65
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_NO_ZERO_CROSSING_STARTUP_FROM_OFF 0x1000
66
ERROR_INDUCTION_CONTROL_ERROR0x83131
IGBT_ERR_TEMPERATURE 0x2000
67
68
BLOWER FAN CALIBRATION RESULTS F20x720229186RPM of test
69
BLOWER FAN CALIBRATION RESULTS F30x720329187RPM of test
70
BLOWER FAN CALIBRATION RESULTS F40x720429188RPM of test
71
BLOWER FAN CALIBRATION RESULTS F50x720529189RPM of test
72
BLOWER FAN CALIBRATION RESULTS F60x720629190RPM of test
73
BLOWER FAN CALIBRATION RESULTS F70x720729191RPM of test
74
BLOWER FAN CALIBRATION RESULTS F80x720829192RPM of test
75
BLOWER FAN CALIBRATION RESULTS F90x720929193RPM of test
76
BLOWER FAN CALIBRATION RESULTS FA0x720A29194RPM of test
77
BLOWER FAN CALIBRATION RESULTS FB0x720B29195RPM of test
78
79
BLACK INDUCTION ERRORS
80
ERROR_IGBT_OC_MEASURED 0x020x800232770
81
ERROR_ZERO_CROSS_TIMEOUT 0x030x800332771
82
ERROR_ZERO_CROSS_TIMEOUT_START_INDUCTION 0x040x800432772
83
ERROR_TIMEON_EXCEED_1HR 0x050x800532773
The induction power was running for more than one hour without being turned off. This can happen if the R1 was in preheat for a long time and then roasting was started. The induction board has a built in timer for maximum one hour of continous induction power.
Induction board timeout after 1hr
84
ERROR_WRONG_I2C_COMMAND 0x060x800632774
85
ERROR_IGBT_OC_ANALOGUE 0x070x800732775Induction coil has a short circuit
86
ERROR_READINDUCTIONREGISTERS3 0x080x800832776
87
ERROR_IGBT_OVERHEATING 0x090x800932777Induction IGBT temperature too high
88
ERROR_NTC_FAILURE 0x0a0x800A32778
IGBT Temp probe malfunction
Induction temperature probe failure
89
ERROR_OTHER_ERROR 0x0b0x800b32779
90
ERROR_NO_CURRENT_STARTUP 0x0c0x800c32780Induction no current
91
ERROR_CANNOT_LOAD_EEPROM_CALIBRATIONS 0x0e0x800e32782Induction memory error
92
0x800f32783
93
ERROR_IGBT_VLINK_TOO_HIGH 0x100x801032784Induction voltage too high
94
ERROR_IGBT_VLINK_TOO_LOW 0x110x801132785Induction voltage too low
95
ERROR_IGBT_ERR_NO_DRUM 0x120x801232786
No drum detected. This error normally comes at the same time as 32780
No drum detected 5S/CE version, check Thermal Switch
96
ERROR_ZERO_CROSS_TIMEOUT_STOP 0x130x801332787
97
98
99
Error messages on the Bullet. These will be shown as ErC and are normally associated with a USB error message as well
100
SAFETYCHECKS_CRITICALCHECK_BEANTEMPTOOHIGH_BIT11Bean Probe Over 240°C or Shorted