ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Parameter no.Size (bytes)RangeDefault valueValuesLabelShort DescriptionFull Description
2
110/1/330 – LED doesn't blink on status change
1 – LED blinks on for vibration status change
2 – LED blinks on for tilt status change
3 – LED blinks on for vibration or tilt status change
LED IndicatorDecide if you want the LED indicator to blink when open/close tilt and/or vibration status changes.Decide if you want the LED indicator to blink when open/close tilt and/or vibration status changes.
0 – LED doesn't blink on status change
1 – LED blinks on for vibration status change
2 – LED blinks on for tilt status change
3 – LED blinks on for vibration or tilt status change
3
211~5051-50 %Battery Reporting ThresholdSet the threshold for battery reporting in % changes.Set the threshold for battery reporting in % changes.
4
3110~502010-50 %Low Battery ReportWhich % level should the device report low battery to the hub.Decide when the sensor should report low battery to the hub.
5
410/1/200 – High sensitivity
1 – Medium sensitivity
2 – Low sensitivity
Vibration Sensor SensitivitySet the vibration sensor's level of sensitivity (0 – high, 1 – medium, 2 – low)Set the vibration sensor's level of sensitivity according to these values:
0 – highest level of sensitivity, will report the recorded vibration immediately;
1 – medium level of sensitivity, will report only if the vibration is recorded for 1.5 seconds or longer, it will keep reporting vibration for 2 more seconds after the last recorded activity;
2 – lowest level of sensitivity, will report only if the vibration is recorded for 2.5 seconds or longer, it will keep reporting vibration for 3 more seconds after the last recorded activity.
6
540~360000-3600 (seconds)
ON Basic Set Reporting Delay to Group 2
Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.
7
640~360000-3600 (seconds)
OFF Basic Set Reporting Delay to Group 2
Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.
8
710/1/220 – Only tilt sensor enabled
1 – Only vibration sensor enabled
2 – Both sensors enabled
Disable Tilt or Vibration SensorDecide if you'd like to disable the vibration (0) or tilt sensor (1) or keep both enabled (2).Decide if you'd like to disable the vibrationor tilt sensor or keep both sensors enabled for reporting. Values:
0 – only tilt sensor enabled
1 – only vibration sensor enabled
2 – both sensors enabled
9
810/1/2/330 – Basic Set commands to Group 2 disabled
1 – Only Basic Set ON to Group 2 enabled
2 – Only Basic Set OFF to Group 2 enabled
3 – All Basic Set commands to Group 2 enabled
Tilt Sensor Basic Set CommandsDecide what type of Basic Set commands are sent to devices in Group 2 when tilt sensor is triggered (expert users only). Decide what type of Basic Set commands are sent to devices associated in Group 2 when the tilt sensor is triggered (expert users only). Values:
0 – all Basic Set commands to Group 2 disabled;
1 – only Basic Set ON (0xFF door open) commands to Group 2 enabled;
2 – only Basic Set OFF (0x00 door closed) commands to Group 2 enabled;
3 – both Basic Set commands (for on and off) to Group 2 enabled.
10
910/1/2/330 – Basic Set commands to Group 3 disabled
1 – Only Basic Set ON to Group 3 enabled
2 – only Basic Set OFF to Group 3 enabled
3 – All Basic Set commands to Group 3 enabled
Vibration Sensor Basic Set CommandsDecide what type of Basic Set commands are sent to devices in Group 3 when vibration sensor is triggered (expert users only). Decide what type of Basic Set commands are sent to devices associated in Group 3 when the vibration sensor is triggered (expert users only). Values:
0 – all Basic Set commands to Group 3 disabled;
1 – only Basic Set ON (0xFF vibration) commands to Group 3 enabled;
2 – only Basic Set OFF (0x00 no vibration) commands to Group 3 enabled;
3 – both Basic Set commands (for on and off) to Group 3 enabled.
11
1021~360031-3600 secondsVibration Clear DelayThe amount of time the device waits to send a vibration clear notification after the last vibration event is detected.The amount of time the device waits to send a vibration clear (tamper clear) notification after the last vibration event is detected.
12
1110/100 – Normally closed
1 – Normally open
Tilt Open / Close OrientationDecide whether the tilt sensor reports closed (0) or open (1) in the default position (not tilted).Decide whether the tilt sensor reports closed or open in the default position (not tilted).
0 – Normally closed (reports closed if the tilt angle is smaller than the angle set in parameter 15; reports open if the tilt angle is larger than the angle set in parameter 14)
1 – Normally open (reports open if the tilt angle is smaller than the angle set in parameter 15; reports closed if the tilt angle is larger than the angle set in parameter 14)
13
1210-1050 – No delay
1-10 (50-500 milliseconds)
Vibration Trigger DelayThe amount of time the device waits to send a vibration notification after the first vibration event is detected.The amount of time the device waits to send a vibration notification (tamper detected) after the first vibration event is detected.
Values:
0 – no delay (sends vibration event immediately)
1-10 where value 1 corresponds to 50 milliseconds, value 2 corresponds to 100 milliseconds, value 3 corresponds to 150 milliseconds, etc, and finally value 10 correspond to 500 milliseconds. So if value 5 is set by default, the sensor will send a vibration alert after the vibration is detected for at least 250 milliseconds.
14
1310/1/200 – Enabled regardless of status
1 – Disabled when tilt in open status
2 – Disabled when tilt in closed status
Disable Vibration Sensor ConditionallyDisable vibration sensor based on the tilt sensor's open / close status. See documentation for details (expert users only).Disable vibration sensor based on the tilt sensor's open / close status so the vibration sensor reports change of status to the hub when specific tilt sensor conditions are met. Expert users only.
Values:
0 – vibration sensor enabled regardless of tilt sensor's status
1 – vibration sensor disabled when tilt sensor is in open status
2 – vibration sensor disabled when tilt sensor is in closed status
15
14160~908060-90 degreesTilt Sensor Open AngleSet the angle of the tilt sensor open state (the status will change if the physical tilt angle exceeds the set value).Set the angle of the tilt sensor open state (the status will change if the physical tilt angle exceeds the set value) in the normally closed orientation (see parameter 11). For example, if the tilt angle is set to 80 degrees, the sensor will report open to the hub once the tilt physically tilts over 80 degrees.
16
1510~2050-20 degreesTilt Sensor Closed AngleSet the angle of the tilt sensor close state (the status will change if the physical tilt angle falls below the set value).Set the angle of the tilt sensor closed state (the status will change if the physical tilt angle falls below the set value) in the normally closed orientation (see parameter 11). For example, if the tilt angle is set to 5 degrees, the sensor will report open to the hub once the tilt physically tilts back under 5 degrees.
17
1610/100 – Exit calibration mode
1 – Enter calibration mode
Tilt Sensor CalibrationSet to value 1 for manual calibration mode over 5 degrees. See documentation for details (expert users only).Set the device to value 1 to enter manual calibration mode if the default position of the sensor exceeds 5 degrees. Then wake the sensor up manually (click the Z-Wave button 4 times quickly) to calibrate. After calibration is complete, revert the parameters value to 0 to exit calibration mode. Expert users only.
18
1710/1/200 – Vertical tilt enabled, horizontal tilt disabled
1 – Vertical tilt enabled, horizontal tilt enabled
2 – Vertical tilt disabled, horizontal tilt enabled
Tilt Sensor DirectionChoose which tilt direction the sensor should report to the hub (see documentation for details, expert users only).Choose which tilt direction the sensor should report to the hub (see documentation for details, expert users only). Values:
0 – Vertical tilt enabled, horizontal tilt disabled
1 – Vertical tilt enabled, horizontal tilt enabled
2 – Vertical tilt disabled, horizontal tilt enabled
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100