Inspection of LC gate No. (non Interlocked) Date: Time: 00:00 hrs.
2
3
4
SNItems to be checked whether As per STD
5
Inspecting Authority
6
Date of Inspection
7
1OVH should not be overdue.
8
2Flag
9
(i)Banner Flag3
10
(ii)Red Hand Signal3
11
(iii)Green Hand Signal1
12
3Tri Colour Torch 03 nos.3
13
4pipe at a distance of 05 meters from check rail end to place banner flag.
14
(i)One end2
15
(ii)Other end2
16
5Long chain with stop disc to lock if boom gets defective.2
17
6small apare chain and padlock two nos.
18
(i)Chain2
19
(ii)Padlock2
20
7Detonator 10 nos. with validity10
21
8Gate lamps = 02 nos2
22
9Tommy bar = 01 nos.1
23
10Mortar pan = 01 nos.1
24
11spade1
25
12Rammer1
26
13Pick axle1
27
14Water pot1
28
15Set of spare spectacles
29
16Protection digramONE
30
17Basket1
31
18Whistle1
32
19wall clock1
33
20Staffs suitable to exhibition of red lamp/flag.Smooth road surface.2
34
21Smooth road surface.
35
(i)LHLH
36
(ii)RHRH
37
22Road signage board
38
(i)Double strip2
39
(ii)Single Strip2
40
(iii)Speed Breaker Board2
41
23Railway act board
42
(i)LH1
43
(ii)RH1
44
24Proper speed breaker2
45
25Gate posts at least 3m away from centre of track with TVU, OVH, gate no. And KM post updated.OK
46
(i)LH2
47
(ii)RH2
48
26Cross slope of gate approach as per extent rule Available
49
27gate lodge to be provided at least 6m from road edgeAvailable
50
(i)Gate lodge to be provided at least 6m from centre of track
51
28Wicket gate condition.
52
29Boom height95mm
53
30Check rail gap = 51-57 mm.51mm
54
(i)RHS
55
(ii)LHS
56
(v)Record
57
32Gate working rule
58
(i)English1
59
(ii)Hindi1
60
(iii)Local1
61
33Gate book in local language1
62
34Duty roster1
63
35Gate Inspection Book.1
64
36Public complain book1
65
37Unusulal register1
66
38list of tools and equipments.1
67
39Bio data of gateman, PME, refresher and competency certificate availibility.
68
(i)PME
69
(ii)REF
70
(iii)Competency certificate
71
40Accident register1
72
41Gate census availibility and where overdue or not.1
73
42S & T register in case of interlocked gate1
74
43Log book1
75
44Private no. sheet.1
76
45Solar light/Electric.
77
(i)Street
78
(ii)Goomty
79
46Road signal RHS
80
47Road Signal LHS
81
82
83
84
85
Inspecting Authority
86
87
88
Copy to: -
89
90
91
92
93
94
95
96
97
98
99