A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | AA | AB | AC | AD | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Make a copy so you can adjust the variables, like rotor material or fuel | "Effective" calculates turbine params for arbitrary, non-optimal fuel flow. Useful if you wish to use overflow mode or save fuel. | ||||||||||||||||||||||||||||
2 | ||||||||||||||||||||||||||||||
3 | Turbine Selector | SC Steam Turbine | Large Gas Turbine | Large Plasma Generator | ||||||||||||||||||||||||||
4 | Rotor Material | Duranium (11) | Tight/Loose Mode | Tight | Tight/Loose Mode | Tight | Tight/Loose Mode | Loose | ||||||||||||||||||||||
5 | Rotor Size | Huge | Fuel Type | SC Steam | Fuel Type | Benzene | Fuel Type | Helium Plasma | ||||||||||||||||||||||
6 | Efficiency | 240.00% | Optimal | Fuel Flow [L/t] (reg. tier) | 102,400 (ZPM) | Optimal | Fuel Flow [L/t] (reg. tier) | 284 (HV) | Optimal | Fuel Flow [L/s] | 338 (LV) | |||||||||||||||||||
7 | Durability | 16,384,000 | Output [EU/t] | 245,760 | Output [EU/t] | 245,376 | Output [EU/t] | 2,547,384 | ||||||||||||||||||||||
8 | Optimal Steam Flow, [L/t] | 102,400 | Dynamo Output [ZPM] | 1.875 Amps | Dynamo Output [EV] | 119.813 Amps | Dynamo Output [ZPM] | 19.435 Amps | ||||||||||||||||||||||
9 | Energy From Optimal Gas Flow [EU/t] | 245,760 | Effective Fuel Flow | Optimal | Effective Fuel Flow | Optimal | Effective Fuel Flow | Optimal | ||||||||||||||||||||||
10 | Energy From Optimal Plasma Flow [EU/t] | 645,120 | Effective | Fuel Flow [L/t] | 102,400 | Effective | Fuel Flow [L/t] | 284 | Effective | Fuel Flow [L/s] | 338 | |||||||||||||||||||
11 | Output [EU/t] | 245,760 | Output [EU/t] | 245,376 | Output [EU/t] | 2,547,384 | ||||||||||||||||||||||||
12 | 2.7.0-2.7.3 | To version 2.3.0.0 <<< | Dynamo Output [EV] | 120.000 Amps | Dynamo Output [LuV] | 7.488 Amps | Dynamo Output [UV] | 4.859 Amps | ||||||||||||||||||||||
13 | To version 2.6.0 <<< | Rotor Lifetime [days] | 5.53 | Rotor Lifetime [days] | 11.07 | Rotor Lifetime [days] | 1.36 | |||||||||||||||||||||||
14 | ||||||||||||||||||||||||||||||
40 | ||||||||||||||||||||||||||||||
41 | Sources Of Steam For Turbines (Steam Generation Tab) | XL Turbo SC Steam Turbine | XL Turbo Gas Turbine | XL Turbo Plasma Turbine | ||||||||||||||||||||||||||
42 | Optimal | Optimal flow for your rotor | Tight/Loose Mode | Loose | Tight/Loose Mode | Tight | Tight/Loose Mode | Tight | ||||||||||||||||||||||
43 | Manual input | Set flow as you wish | Fuel Type | SC Steam | Fuel Type | Nitrobenzene | Fuel Type | Celestial Tungsten Plasma | ||||||||||||||||||||||
44 | LSB | Large Steel Boiler | Is Dense | Optimal | Fuel Flow [L/t] (reg. tier) | 1,024 (EV) | Optimal | Fuel Flow [L/s] | 119 (LV) | |||||||||||||||||||||
45 | LTB | Large Titanium Boiler | Optimal | Fuel Flow [L/t] (reg. tier) | 103,778 (ZPM) | Output [EU/t] | 3,932,160 | Output [EU/t] | 10,281,600 | |||||||||||||||||||||
46 | LTSB | Large Tungstensteel Boiler | Output [EU/t] | 171,855,527 | Dynamo Output [ZPM] | 30 Amps | Dynamo Output [ZPM] | 78.442 Amps | ||||||||||||||||||||||
47 | LHE | Large Heat Exchanger | Dynamo Output [UEV] | 20.487 Amps | Effective Fuel Flow | Optimal | Effective Fuel Flow | Optimal | ||||||||||||||||||||||
48 | EHE | Extreme Heat Exchanger | Effective Fuel Flow | Optimal | Effective | Fuel Flow [L/t] | 1024 | Effective | Fuel Flow [L/s] | 119 | ||||||||||||||||||||
49 | WWXL | Whakawhiti Wera XL | Effective | Fuel Flow [L/t] | 103,778 | Output [EU/t] | 3,932,160 | Output [EU/t] | 10,281,600 | |||||||||||||||||||||
50 | Thermal Boiler | Output [EU/t] | 171,855,527 | Dynamo Output [ZPM] | 30 Amps | Dynamo Output [UHV] | 4.903 Amps | |||||||||||||||||||||||
51 | Dynamo Output [UEV] | 20.487 Amps | Rotor Lifetime [days] | 3.67 | Rotor Lifetime [days] | 1.93 | ||||||||||||||||||||||||
52 | Rotor Lifetime [days] | 0.38 | ||||||||||||||||||||||||||||
53 | The XL SC turbine is ZPM assembler locked and requires Trinium Coils | |||||||||||||||||||||||||||||
54 | or a UV naq alloy EBF/MBF. Non-XL turbines cannot use dense steams! | |||||||||||||||||||||||||||||
68 | Plasma EHE Setup Planner | Non-XL EHE Setup Planner | ||||||||||||||||||||||||||||
69 | Plasma Type | Helium Plasma | Hot Fluid | IC2 Hot Coolant | ||||||||||||||||||||||||||
70 | Recipe Output in Liters | 125 | Hot Fluid Input [L/s] | 32,000,000 L/s | ||||||||||||||||||||||||||
71 | 1 L = 1 mB | mk1, mk2, mk3 = 2/2 oc | Recipe Time in Seconds | 0.8 | EHE Max Input [L/s] | 16,000 L/s | ||||||||||||||||||||||||
72 | As of 2.2.0.0 dynamo hatches do not explode anymore, if output EU/t is more than the dynamo's maximum output (V*A). | mk4, mk5 = 4/4 oc | EU/t per Recipe | 32,720 | Total SC Steam [L/t] | 320,000,000 L/t | ||||||||||||||||||||||||
73 | Turbine output is limited to dynamo capabilities in this case. | Parallel Count | 5 | Total SH Steam [L/t] | 0 L/t | |||||||||||||||||||||||||
74 | Rotor lifetime includes element of random. Average value given. Days and hours are real time. | Plasma Output [L/s] | 781 L/s | Rotor Fit | Loose | |||||||||||||||||||||||||
75 | Put your fluid regulators on input hatches. Do not insert GT pipes between input hatch and regulator, or use fluid p2p instead if thats necessary. | EHE max input [L/s] | 500 L/s | Rotor Efficiency | 165.60% | |||||||||||||||||||||||||
76 | Watch out: plasma flows are in L/s, steam and gas flows are in L/t | Total Dense SC Steam [L/t] | 2,879 L/t | Power per Turbine (SC/SH) | 10,741,074 EU/t | |||||||||||||||||||||||||
77 | Rotor Fit | Loose | SC/SH Dynamo Output [LuV] | 327.79 Amp(s) | ||||||||||||||||||||||||||
78 | Rotor Efficiency | 165.60% | Power per Turbine (Reg) | 5,370,537 EU/t | ||||||||||||||||||||||||||
79 | Power per turbine (SC/HP) | 171,855,527 EU/t | Reg Dynamo Output [LuV] | 163.90 Amp(s) | ||||||||||||||||||||||||||
80 | Power per turbine (Reg) | 85,927,763 EU/t | Rotor Lifespan Value | Average | ||||||||||||||||||||||||||
81 | Excess Steam | 2,879 L/t | Rotor Lifespan (SC) | 2.29 Day(s) | ||||||||||||||||||||||||||
82 | Rotor Lifespan Value | Minimum | Rotor Lifespan (SH) | 1.53 Day(s) | ||||||||||||||||||||||||||
83 | Rotor Lifespan (SC/SH) | 0.38 Day(s) | Rotor Lifespan (Reg) | 2.32 Day(s) | ||||||||||||||||||||||||||
84 | Rotor Lifespan (Reg) | 0.58 Day(s) | Rotor Consumption per Day | 76.1097 / Day | ||||||||||||||||||||||||||
85 | Rotor Consumption per Day | 83.9306 / Day | EHE count | 2,000 EHE(s) | ||||||||||||||||||||||||||
86 | EHE count | 2 EHE(s) | Partial EHE Flowrate | 0 L/s | ||||||||||||||||||||||||||
87 | Optimal Flow (SC/SH/Reg) | 103,778 L/t | Is Partial EHE Below Threshold? | No | ||||||||||||||||||||||||||
88 | SC/HP/Reg turbine count | 1 Turbine(s) | Optimal Flowrate (SC/SH/Reg) | 6,486,156 L/t | ||||||||||||||||||||||||||
89 | Includes Partial Flow Turbines? | Yes | SC Turbine Count | 50 Turbine(s) | ||||||||||||||||||||||||||
90 | Partial Flow (SC/SH/Reg) | 2,879 L/t | Includes Partial Flow SC Turbine? | Yes | ||||||||||||||||||||||||||
91 | Total Turbine Count | 3 Turbine(s) | Partial SC Turbine Flowrate | 2,178,356 L/t | ||||||||||||||||||||||||||
92 | Power Generated | 330,656 EU/t | SH/Reg Turbine Count | 50 Turbine(s) | ||||||||||||||||||||||||||
93 | Dynamo Output [UEV] | 0.04 Amp(s) | Includes Partial Flow SH/Reg Turbines? | Yes | ||||||||||||||||||||||||||
94 | Fusion Power Usage | 163,600 EU/t | Partial SH/Reg Turbine Flowrate | 2,178,356 L/t | ||||||||||||||||||||||||||
95 | Total Turbine Count | 150 Turbine(s) | ||||||||||||||||||||||||||||
96 | Power Generated | 1,318,810,365 EU/t | ||||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||||||
100 | ||||||||||||||||||||||||||||||
101 | ||||||||||||||||||||||||||||||
102 | ||||||||||||||||||||||||||||||
103 | ||||||||||||||||||||||||||||||
104 | ||||||||||||||||||||||||||||||
105 | ||||||||||||||||||||||||||||||
106 | ||||||||||||||||||||||||||||||
107 | ||||||||||||||||||||||||||||||
108 | ||||||||||||||||||||||||||||||
109 | ||||||||||||||||||||||||||||||
110 | ||||||||||||||||||||||||||||||
111 | ||||||||||||||||||||||||||||||
112 | ||||||||||||||||||||||||||||||
113 | ||||||||||||||||||||||||||||||
114 | ||||||||||||||||||||||||||||||
115 | ||||||||||||||||||||||||||||||
116 | ||||||||||||||||||||||||||||||
117 | ||||||||||||||||||||||||||||||
118 | ||||||||||||||||||||||||||||||
119 | ||||||||||||||||||||||||||||||
120 | ||||||||||||||||||||||||||||||
121 | ||||||||||||||||||||||||||||||
122 | ||||||||||||||||||||||||||||||
123 | ||||||||||||||||||||||||||||||
124 | ||||||||||||||||||||||||||||||
125 | ||||||||||||||||||||||||||||||
126 | ||||||||||||||||||||||||||||||
127 | ||||||||||||||||||||||||||||||
128 | ||||||||||||||||||||||||||||||
129 | ||||||||||||||||||||||||||||||
130 | ||||||||||||||||||||||||||||||
131 | ||||||||||||||||||||||||||||||
132 | ||||||||||||||||||||||||||||||
133 | ||||||||||||||||||||||||||||||
134 | ||||||||||||||||||||||||||||||
135 | ||||||||||||||||||||||||||||||
136 | ||||||||||||||||||||||||||||||
137 | ||||||||||||||||||||||||||||||
138 |