Design of Lifting Lug Weld
2
3
Design By:
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
P = 5.5kip
25
θ = 70degrees
Angle Between Y-Axis and P
26
S.F. =3
Safety Factor
Safety factor of 3 is required for lifting lugs. A factor of 2 is common for fall protection systems and other uses.
27
Px = 5.17kip
28
Py = 1.88kip
29
b = 0.5in
30
d = 4.5in
31
32
Aw = 10in
33
c = 2.25in
Distance from Px to Plate
34
Mu = 11.63kip*in
35
36
Sw = 9.00in2
37
fb = 1.29kip/in
38
ft = 0.19kip/in
39
fv = 0.52kip/in
40
41
fr = 1.568kip/in
42
43
D=2.53
Weld Size in Sixteenths of an Inch
44
For E70 Electrodes
45
46
NOTE:
Weld size is based on weld load only. Base material should
47
also be checked!