Current Calibration shared
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

View only
 
ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Measured Current (A)
FC Current (A)Calibrated:
2
0.290.55Scale 400Scale 292mV/10A
3
0.870.97Offset0Offset-337mA
4
2.051.83Values from BF during measurements
The corrected calibration values
5
3.002.55Change these if needed
Set these in betaglight
6
3.502.88
7
Replace these example values.
Max current:112.6766986A
8
Just do a few throttle settings
Shunt resistor:29.2mOhms
9
from around 0 to 5 amps.
These are calculate based on the above calibration values
10
11
Make sure there are at least 3 measurements.
12
Regression:0.9998291577
13
If this is not green then you have probably done something wrong!
14
15
16
17
18
19
20
21
22
Multimeter current in measured column and the corresponding current from betaflight in the FC column
23
You do not need to measure high current values, this should be correct across the full range