ABCDEFGHIJKLMNOPQRSTUVWXYZAAAB
1
TimestampFCC IDERT TypeCommodity TypeOther InfoModel
2
9/14/2014 18:47:53H6NCMM11017ElectricCellNet 40-336
3
12/7/2014 10:33:22F9CC1C-312Electric917.58 MHz . Not sure about units used in consumptionSchlumberger C1SC
4
1/4/2015 22:56:13E330/E350 FOCUS AX25Electriclandis+gyr
5
1/29/2015 18:58:02P2SNTGSRFV30WaterR900Neptune 12512 - 40G
6
2/27/2015 17:30:06TEB-HUNTSU8647ElectricInstalled by Hydro Quebec in MontrealLandis Gyr Gridstream RF FOCUS AXR-SD
7
3/11/2015 19:45:16EWQ100GDLAN12GasItron 100G DLN
8
3/18/2015 8:49:53TEB-AIRPT6225ElectricPSE&G branded meter, 2010.Landis+Gyr AirPoint FOCUS
9
3/24/2015 19:13:52GIF2006B12Waternot sure of ERT, none listed on deviceOrion Pit badger meter
10
4/12/2015 13:42:48N/A2GasLower=908MHz, Upper=924MHz40G, 40GB
11
4/14/2015 20:15:59F9CR300-44ElectricAMR R300Schlumberger J5S
12
6/12/2015 21:07:47P2SNTGSRFV30WaterConsumption number never changes and appears to be incorrect.Neptune R900
13
7/25/2015 13:21:00SK9C1A-37ElectricItron C1SR
14
9/12/2015 19:27:14CDT5XESS8ElectricThis meter monitors kilowatts in and out for solar. I'm still trying to determine how to read the values from rtlamr for usage, but I can easily see the kWh out value. Itron FM2S
15
11/22/2015 12:55:11r7peg1r1s27Electrictype FOCUS AXR-SDGRIDSTREAM RF
16
12/13/2015 23:00:22F9CC1R-14Electric910 MHz - 920 MHzSchlumberger CENTRON
17
1/30/2016 19:36:58SK9C1A-37ElectricItron C1SR
18
9/16/2016 23:56:20P2SR900M11WaterPart no: RD2G13. Not sure about the ERT type so I just filled it in with 11.Neptune E-Coder R900i
19
10/27/2016 17:24:41SK9AMI-40ElectricERT? ####C2SOD
20
10/30/2016 13:22:06EWQ100GDLBS12GasSCM+Itron 100G DLS
21
12/7/2016 13:59:31F9CC1R-14ElectricNot sure if thats the correct type. rtlamr is saying type 4. If you need more info please email me brainapps@gmail.com. I do have 2 identical meters though (1 for upstairs and 1 for downstairs) with different ids but only 1 of the ids ever show up in rtlamr. Any ideas? Schlumberger Centron C1SR
22
12/21/2016 15:09:23EWQ100GDLAN12GasElster AC250
23
1/13/2017 15:41:29F9CR300-44ElectricArgh - copied the wrong value on the last submission. It's actually type 4Schlumberger AMR R300
24
2/15/2017 5:15:37NA0Waterno more info, just the ID only.EquaScan w MIU rf
25
2/21/2017 18:02:53SK9C1A-27ElectricWorks great w/default settings & filterid from barcode at top - "City of Los Angeles" (LADWP) meterItron C1SR
26
2/25/2017 16:27:26TEB-HUNTSU8644ElectricFOCUS AXR-SD
27
4/24/2017 0:56:48SK9C1A-37Electrictron C1SR
28
4/29/2017 9:42:19SK9C1A-38ElectricC1SR
29
5/24/2017 6:27:47SK9AMI-74ElectricC2M
30
6/16/2017 15:20:43SK9C3A - 1H4ElectricNot sure about the ERT type. It displays '4' and consumption in kWh which I am receiving in scm+ mode. Type 10 is production and that is not being received. This is a net meter.Itron C2SNR
31
7/7/2017 9:44:50F9CC1R-14ElectricCENTRON C1SR
32
7/21/2017 14:30:31EWQ100WD11WaterItron 100WRD
33
9/10/2017 8:28:36OWS-NIC7147Electrichttps://fccid.io/OWS-NIC714 *** Comed IllinoisI-210+C
34
11/18/2017 19:35:34F9CR300-4441832ElectricThis is a daughterboard installed in a standard analog meter with 5 hands.Schlumberger J5J1S
35
12/31/2017 16:07:45TEB-AIRPT6575ElectricGE I-210 HP-RF
36
1/7/2018 16:56:15OWS-NIC5144ElectricSilver Spring Networks NIC 314
37
1/10/2018 7:44:40F9CC1R-14ElectricMarked Schlumberger Centron(TM)Schlumberger C1SR
38
1/13/2018 10:02:24Unknown12GasERG-1006-501,502,503,504,505,506,507,508,509,511,513,515,516Itron 40GB
39
2/2/2018 12:35:14P9X-410CL4ElectricItron
40
2/2/2018 14:26:50F9CC1R-14ElectricSchlumberger C1SR
41
3/13/2018 21:15:53OWS-NIC51441Electrichttp://www.gegridsolutions.com/products/brochures/i210_family.pdfGE FM2S
42
6/18/2018 13:54:55NTAXMETER21395.2926WaterMaster Meter 10046353
43
6/29/2018 12:27:41SK9AMI714ElectricNet MeterCS2B
44
7/5/2018 21:22:22OWS-NIC5140ElectricPG&E MeterLandis+Gyr Focus AXR-SD
45
10/26/2018 14:36:35FCCID: E0940GN-1, CANADA: 864-101732A12GasItron 50W
46
1/15/2019 6:11:44SK9AMI7, IC:864G-AMI714ElectricAMI7
47
3/2/2019 16:47:54SK9C3A-1H08ElectricItron C1SDR3
48
3/29/2019 14:45:36F9CC1R-104ElectricSchlumberger C1SR
49
7/14/2019 16:20:48EWQ500G814GasNW Natural in Portland, ORItron 500G
50
8/8/2019 12:49:01SK9AMI704ElectricERT type is a guess, it is NOT on the meter. The serial number appears to be in hex or alpanumeric (as some letters A-F)Itron C2M
51
9/20/2019 17:38:09SK9AMI714ElectricNetmeter. Reports as type 110 in RTL-SDR. {"Time":"2019-09-20T17:35:42.619594525-06:00","Offset":0,"Length":0,"Type":"SCM+","Message":{"FrameSync":5795,"ProtocolID":30,"EndpointType":110,"EndpointID":####,"Consumption":26812554,"Tamper":16552,"PacketCRC":####}}C2SO
52
10/3/2019 14:23:16SK9C1A307ElectricAppears to send SCM+ message onlyC1SR6
53
11/11/2019 9:46:45EWQ100GDLBS12GasItron 100G DLT
54
12/9/2019 22:21:47OWS-NIC511-0312ElectricAEP Ohio/USA (Aclara/Silver Springs Networks)Itron NIC511-03
55
12/13/2019 8:42:08ewqrivawa13WaterOpenWay 1601-001
56
1/24/2020 15:38:20SK9C1A-307ElectricCN1SRP
57
1/27/2020 18:40:49EWQ100GDLAS12GasUnlike the electric meters, a bit of a pain to figure out which is which because the reading likely doesn't match the frontItron 100G DLS
58
3/5/2020 16:02:17ewq100wc11WaterTucson, AZItron 100wc
59
8/21/2020 16:35:50EWQ100WD11Water100WD
60
1/13/2021 13:40:54F9CC1SA-104ElectricItron C1SR
61
1/22/2021 13:39:52SBDFLEXI2100ElectricAclara I-210+c
62
1/25/2021 20:03:13SK9C3A-2H08ElectricThis is a net meter, so I assume it's type 8. It's the same model listed in https://diysolarforum.com/threads/using-rf-to-read-itron-utility-meters.4038/Itron C3A2H
63
2/8/2021 20:55:47E0940GN-113WaterI am not sure if it's ERT Type 13. I am unable to discover the unit.Itron ERW-1008-505
64
2/10/2021 12:11:52P2SR900M15WaterNeptune R900M
65
2/25/2021 5:45:54EWQ100GDLAS12GasSends via SCM+ in 903-926.85 MHz range (Source: https://www.itron.com/-/media/feature/products/documents/spec-sheet/100g-dls-spec-sheet.pdf and https://fccid.io/EWQ100GDLAS)Itron 100GDLS
66
3/12/2021 11:30:37SK9C1A-3B07Electrichttp://fcc.io/SK9C1A-3BItron C1SR
67
4/6/2021 19:23:59SK9AMI704ElectricItron AMI7
68
4/16/2021 6:31:16R7PEG1R1S55ElectricGRIDSTREAM RF, ZigBee, Contains IC: 5294A-EG1R1S5, Module Model: G5 26-1905, Can not find Frequency...Landis+Gyr FOCUS AXR3-SD
69
5/12/2021 18:44:10SK9AMI700ElectricThe ERT Type looks different that what you have displayed in the example. The number encoded in the barcode starts with 00016X#X##... where X=Alpha and #=numericItron C2M
70
6/26/2021 8:30:14EWQ100WD11WaterMessage Type: SCM+100WD
71
8/15/2021 23:29:13SK9C3A-2H07ElectricC3A2H
72
9/2/2021 20:21:07SK9ACT207Electricltron C2SRD
73
9/6/2021 9:10:08R7PEG1R1S60000000ElectricI don't see a clear ERT type, please check it: https://i.imgur.com/MP6B4o7.pngG5 Integrated FOCUS AXe
74
9/6/2021 9:15:06ows-nic531-0613Electricc2sl
75
9/25/2021 23:25:11SK9AMI714ElectricThis is a net meter with a PV system and I can get the SCM+ messages for the consumption from the grid. Can't figure out how to get the production value going back to the grid when the PV is overproducing. The consumption counter from the grid just plateaus (never goes down) when the PV is overproducing.C2SO
76
11/19/2021 23:48:41EO940GN-103Waterhttps://fcc.io/EO940GN-1, freq: 910-920MHz, confusingly the "50W" model number is in small print and in large print is "ERW 1008 506" which is like a "sub-model" number indicating a variation for the particular physical meter it is mounted toItron 50W
77
11/19/2021 23:50:30EWQ100GDLAN12Gashttps://fcc.io/EWQ100GDLANItron 100G
78
11/21/2021 17:44:55F9CC1R-104ElectricSchlumberger C1SR
79
1/4/2022 21:00:16CDT5XESS07ElectriciTron I-210+
80
1/21/2022 14:23:42EWQ500GA12GasSCM+ it appears, 10 digit unique identifier.Itron GEN5 500G
81
2/20/2022 10:38:34SDBIDTB00104ElectricSensus iCon iSA2 with Flexnet 530X Smart MeteriSA2
82
3/24/2022 17:16:40R7PER6R1S202GasI am not confident I got the ERT Type correct.Landis+Gyr Gridstream 120M-1
83
4/7/2022 13:56:49F9CC1R-104ElectricI think this is a pre-Itron acquisition C1SR. Looks nearly identical but FCC-ID is different though.Schlumberger C1SR
84
4/19/2022 9:58:29SK9C1A-3B07ElectricProtocol is SCM+Itron C1SR
85
4/19/2022 19:56:23EWQINTELISG220GasSCM+:{ProtocolID:0x1E EndpointType:0xDC EndpointID: #### Consumption: 95309 Tamper:0x0B00 PacketCRC:0x####}}Itron ERG-7100-005
86
5/2/2022 16:11:18CDT5XESS07ElectricItron 5XESS
87
6/25/2022 22:39:18EWQ500GA30GasItron Openway RIVA 500G ERT
88
6/27/2022 22:44:35Unsure00Waterrtlamr successfully reads my water meter but the meter does not have a FCC ID or ERT listed.Neptune MACH10)R900i v4
89
7/10/2022 13:00:02EWQ100GDLAS12GasAccording to Itron docs, DLT == DLS hardware using SCM, rather than SCM+ used by DLSItron 100G DLT
90
10/2/2022 20:54:14SK9G5R104ElectricI don't think it is reading my meter data yet, I have not seen my Serial Number pop up. I have a net meter for my solar.Itron R2SID
91
10/21/2022 13:05:13SK9C1A-307ElectricNorthwestern Energy in Billings, Montana Set in NET Metering Mode, Works GREAT!Itron C1A-3
92
10/21/2022 13:19:23EWQ100GDLAS12GasMontana-Dakota Utilities (MDU) Billings, MT Installed 06/10/2018Itron 100G DLS
93
10/21/2022 13:21:48P2SR900M11WaterCity of Billings Water Works Mfg. 10/10/2018Neptune R900 V4
94
10/24/2022 15:27:04Landis+Gyr07ElectricLandis+Gyrl
95
11/8/2022 10:50:07OZFACXX2000Electricjake541@gmail.comIntron C2SD
96
11/8/2022 11:15:16OZFACXX2012ElectricCorrected submission - jake541@gmail.com - https://imgur.com/a/wbnfuaOItron C2SD
97
1/16/2023 9:23:15R7PEG1R1S505ElectricCould not find ERT type; Module Model: G5 26-1905; 50D3B0F9; Landis+Gyr (Gridstream RF) Focus AXRe-SD
98
2/27/2023 16:12:24unknown00ElectricTrilliant meters use zigbee secureTrilliant
99
5/20/2023 8:52:39EWQ100GDLAS12Gas100GDLAS
100
5/24/2023 23:56:26qzc-rx2ea4f41Electricelster r2sd