A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | AA | AB | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Timestamp | FCC ID | ERT Type | Commodity Type | Other Info | Model | ||||||||||||||||||||||
2 | 9/14/2014 18:47:53 | H6NCMM1101 | 7 | Electric | CellNet 40-336 | |||||||||||||||||||||||
3 | 12/7/2014 10:33:22 | F9CC1C-3 | 12 | Electric | 917.58 MHz . Not sure about units used in consumption | Schlumberger C1SC | ||||||||||||||||||||||
4 | 1/4/2015 22:56:13 | E330/E350 FOCUS AX | 25 | Electric | landis+gyr | |||||||||||||||||||||||
5 | 1/29/2015 18:58:02 | P2SNTGSRFV3 | 0 | Water | R900 | Neptune 12512 - 40G | ||||||||||||||||||||||
6 | 2/27/2015 17:30:06 | TEB-HUNTSU864 | 7 | Electric | Installed by Hydro Quebec in Montreal | Landis Gyr Gridstream RF FOCUS AXR-SD | ||||||||||||||||||||||
7 | 3/11/2015 19:45:16 | EWQ100GDLAN | 12 | Gas | Itron 100G DLN | |||||||||||||||||||||||
8 | 3/18/2015 8:49:53 | TEB-AIRPT622 | 5 | Electric | PSE&G branded meter, 2010. | Landis+Gyr AirPoint FOCUS | ||||||||||||||||||||||
9 | 3/24/2015 19:13:52 | GIF2006B | 12 | Water | not sure of ERT, none listed on device | Orion Pit badger meter | ||||||||||||||||||||||
10 | 4/12/2015 13:42:48 | N/A | 2 | Gas | Lower=908MHz, Upper=924MHz | 40G, 40GB | ||||||||||||||||||||||
11 | 4/14/2015 20:15:59 | F9CR300-4 | 4 | Electric | AMR R300 | Schlumberger J5S | ||||||||||||||||||||||
12 | 6/12/2015 21:07:47 | P2SNTGSRFV3 | 0 | Water | Consumption number never changes and appears to be incorrect. | Neptune R900 | ||||||||||||||||||||||
13 | 7/25/2015 13:21:00 | SK9C1A-3 | 7 | Electric | Itron C1SR | |||||||||||||||||||||||
14 | 9/12/2015 19:27:14 | CDT5XESS | 8 | Electric | This meter monitors kilowatts in and out for solar. I'm still trying to determine how to read the values from rtlamr for usage, but I can easily see the kWh out value. | Itron FM2S | ||||||||||||||||||||||
15 | 11/22/2015 12:55:11 | r7peg1r1s2 | 7 | Electric | type FOCUS AXR-SD | GRIDSTREAM RF | ||||||||||||||||||||||
16 | 12/13/2015 23:00:22 | F9CC1R-1 | 4 | Electric | 910 MHz - 920 MHz | Schlumberger CENTRON | ||||||||||||||||||||||
17 | 1/30/2016 19:36:58 | SK9C1A-3 | 7 | Electric | Itron C1SR | |||||||||||||||||||||||
18 | 9/16/2016 23:56:20 | P2SR900M | 11 | Water | Part no: RD2G13. Not sure about the ERT type so I just filled it in with 11. | Neptune E-Coder R900i | ||||||||||||||||||||||
19 | 10/27/2016 17:24:41 | SK9AMI-4 | 0 | Electric | ERT? #### | C2SOD | ||||||||||||||||||||||
20 | 10/30/2016 13:22:06 | EWQ100GDLBS | 12 | Gas | SCM+ | Itron 100G DLS | ||||||||||||||||||||||
21 | 12/7/2016 13:59:31 | F9CC1R-1 | 4 | Electric | Not sure if thats the correct type. rtlamr is saying type 4. If you need more info please email me brainapps@gmail.com. I do have 2 identical meters though (1 for upstairs and 1 for downstairs) with different ids but only 1 of the ids ever show up in rtlamr. Any ideas? | Schlumberger Centron C1SR | ||||||||||||||||||||||
22 | 12/21/2016 15:09:23 | EWQ100GDLAN | 12 | Gas | Elster AC250 | |||||||||||||||||||||||
23 | 1/13/2017 15:41:29 | F9CR300-4 | 4 | Electric | Argh - copied the wrong value on the last submission. It's actually type 4 | Schlumberger AMR R300 | ||||||||||||||||||||||
24 | 2/15/2017 5:15:37 | NA | 0 | Water | no more info, just the ID only. | EquaScan w MIU rf | ||||||||||||||||||||||
25 | 2/21/2017 18:02:53 | SK9C1A-2 | 7 | Electric | Works great w/default settings & filterid from barcode at top - "City of Los Angeles" (LADWP) meter | Itron C1SR | ||||||||||||||||||||||
26 | 2/25/2017 16:27:26 | TEB-HUNTSU864 | 4 | Electric | FOCUS AXR-SD | |||||||||||||||||||||||
27 | 4/24/2017 0:56:48 | SK9C1A-3 | 7 | Electric | tron C1SR | |||||||||||||||||||||||
28 | 4/29/2017 9:42:19 | SK9C1A-3 | 8 | Electric | C1SR | |||||||||||||||||||||||
29 | 5/24/2017 6:27:47 | SK9AMI-7 | 4 | Electric | C2M | |||||||||||||||||||||||
30 | 6/16/2017 15:20:43 | SK9C3A - 1H | 4 | Electric | Not sure about the ERT type. It displays '4' and consumption in kWh which I am receiving in scm+ mode. Type 10 is production and that is not being received. This is a net meter. | Itron C2SNR | ||||||||||||||||||||||
31 | 7/7/2017 9:44:50 | F9CC1R-1 | 4 | Electric | CENTRON C1SR | |||||||||||||||||||||||
32 | 7/21/2017 14:30:31 | EWQ100WD | 11 | Water | Itron 100WRD | |||||||||||||||||||||||
33 | 9/10/2017 8:28:36 | OWS-NIC714 | 7 | Electric | https://fccid.io/OWS-NIC714 *** Comed Illinois | I-210+C | ||||||||||||||||||||||
34 | 11/18/2017 19:35:34 | F9CR300-4 | 441832 | Electric | This is a daughterboard installed in a standard analog meter with 5 hands. | Schlumberger J5J1S | ||||||||||||||||||||||
35 | 12/31/2017 16:07:45 | TEB-AIRPT657 | 5 | Electric | GE I-210 HP-RF | |||||||||||||||||||||||
36 | 1/7/2018 16:56:15 | OWS-NIC514 | 4 | Electric | Silver Spring Networks NIC 314 | |||||||||||||||||||||||
37 | 1/10/2018 7:44:40 | F9CC1R-1 | 4 | Electric | Marked Schlumberger Centron(TM) | Schlumberger C1SR | ||||||||||||||||||||||
38 | 1/13/2018 10:02:24 | Unknown | 12 | Gas | ERG-1006-501,502,503,504,505,506,507,508,509,511,513,515,516 | Itron 40GB | ||||||||||||||||||||||
39 | 2/2/2018 12:35:14 | P9X-410CL | 4 | Electric | Itron | |||||||||||||||||||||||
40 | 2/2/2018 14:26:50 | F9CC1R-1 | 4 | Electric | Schlumberger C1SR | |||||||||||||||||||||||
41 | 3/13/2018 21:15:53 | OWS-NIC514 | 41 | Electric | http://www.gegridsolutions.com/products/brochures/i210_family.pdf | GE FM2S | ||||||||||||||||||||||
42 | 6/18/2018 13:54:55 | NTAXMETER21395.29 | 26 | Water | Master Meter 10046353 | |||||||||||||||||||||||
43 | 6/29/2018 12:27:41 | SK9AMI7 | 14 | Electric | Net Meter | CS2B | ||||||||||||||||||||||
44 | 7/5/2018 21:22:22 | OWS-NIC514 | 0 | Electric | PG&E Meter | Landis+Gyr Focus AXR-SD | ||||||||||||||||||||||
45 | 10/26/2018 14:36:35 | FCCID: E0940GN-1, CANADA: 864-101732A | 12 | Gas | Itron 50W | |||||||||||||||||||||||
46 | 1/15/2019 6:11:44 | SK9AMI7, IC:864G-AMI7 | 14 | Electric | AMI7 | |||||||||||||||||||||||
47 | 3/2/2019 16:47:54 | SK9C3A-1H | 08 | Electric | Itron C1SDR3 | |||||||||||||||||||||||
48 | 3/29/2019 14:45:36 | F9CC1R-1 | 04 | Electric | Schlumberger C1SR | |||||||||||||||||||||||
49 | 7/14/2019 16:20:48 | EWQ500G8 | 14 | Gas | NW Natural in Portland, OR | Itron 500G | ||||||||||||||||||||||
50 | 8/8/2019 12:49:01 | SK9AMI7 | 04 | Electric | ERT type is a guess, it is NOT on the meter. The serial number appears to be in hex or alpanumeric (as some letters A-F) | Itron C2M | ||||||||||||||||||||||
51 | 9/20/2019 17:38:09 | SK9AMI7 | 14 | Electric | Netmeter. Reports as type 110 in RTL-SDR. {"Time":"2019-09-20T17:35:42.619594525-06:00","Offset":0,"Length":0,"Type":"SCM+","Message":{"FrameSync":5795,"ProtocolID":30,"EndpointType":110,"EndpointID":####,"Consumption":26812554,"Tamper":16552,"PacketCRC":####}} | C2SO | ||||||||||||||||||||||
52 | 10/3/2019 14:23:16 | SK9C1A3 | 07 | Electric | Appears to send SCM+ message only | C1SR6 | ||||||||||||||||||||||
53 | 11/11/2019 9:46:45 | EWQ100GDLBS | 12 | Gas | Itron 100G DLT | |||||||||||||||||||||||
54 | 12/9/2019 22:21:47 | OWS-NIC511-03 | 12 | Electric | AEP Ohio/USA (Aclara/Silver Springs Networks) | Itron NIC511-03 | ||||||||||||||||||||||
55 | 12/13/2019 8:42:08 | ewqrivawa | 13 | Water | OpenWay 1601-001 | |||||||||||||||||||||||
56 | 1/24/2020 15:38:20 | SK9C1A-3 | 07 | Electric | CN1SRP | |||||||||||||||||||||||
57 | 1/27/2020 18:40:49 | EWQ100GDLAS | 12 | Gas | Unlike the electric meters, a bit of a pain to figure out which is which because the reading likely doesn't match the front | Itron 100G DLS | ||||||||||||||||||||||
58 | 3/5/2020 16:02:17 | ewq100wc | 11 | Water | Tucson, AZ | Itron 100wc | ||||||||||||||||||||||
59 | 8/21/2020 16:35:50 | EWQ100WD | 11 | Water | 100WD | |||||||||||||||||||||||
60 | 1/13/2021 13:40:54 | F9CC1SA-1 | 04 | Electric | Itron C1SR | |||||||||||||||||||||||
61 | 1/22/2021 13:39:52 | SBDFLEXI210 | 0 | Electric | Aclara I-210+c | |||||||||||||||||||||||
62 | 1/25/2021 20:03:13 | SK9C3A-2H | 08 | Electric | This is a net meter, so I assume it's type 8. It's the same model listed in https://diysolarforum.com/threads/using-rf-to-read-itron-utility-meters.4038/ | Itron C3A2H | ||||||||||||||||||||||
63 | 2/8/2021 20:55:47 | E0940GN-1 | 13 | Water | I am not sure if it's ERT Type 13. I am unable to discover the unit. | Itron ERW-1008-505 | ||||||||||||||||||||||
64 | 2/10/2021 12:11:52 | P2SR900M | 15 | Water | Neptune R900M | |||||||||||||||||||||||
65 | 2/25/2021 5:45:54 | EWQ100GDLAS | 12 | Gas | Sends via SCM+ in 903-926.85 MHz range (Source: https://www.itron.com/-/media/feature/products/documents/spec-sheet/100g-dls-spec-sheet.pdf and https://fccid.io/EWQ100GDLAS) | Itron 100GDLS | ||||||||||||||||||||||
66 | 3/12/2021 11:30:37 | SK9C1A-3B | 07 | Electric | http://fcc.io/SK9C1A-3B | Itron C1SR | ||||||||||||||||||||||
67 | 4/6/2021 19:23:59 | SK9AMI7 | 04 | Electric | Itron AMI7 | |||||||||||||||||||||||
68 | 4/16/2021 6:31:16 | R7PEG1R1S5 | 5 | Electric | GRIDSTREAM RF, ZigBee, Contains IC: 5294A-EG1R1S5, Module Model: G5 26-1905, Can not find Frequency... | Landis+Gyr FOCUS AXR3-SD | ||||||||||||||||||||||
69 | 5/12/2021 18:44:10 | SK9AMI7 | 00 | Electric | The ERT Type looks different that what you have displayed in the example. The number encoded in the barcode starts with 00016X#X##... where X=Alpha and #=numeric | Itron C2M | ||||||||||||||||||||||
70 | 6/26/2021 8:30:14 | EWQ100WD | 11 | Water | Message Type: SCM+ | 100WD | ||||||||||||||||||||||
71 | 8/15/2021 23:29:13 | SK9C3A-2H | 07 | Electric | C3A2H | |||||||||||||||||||||||
72 | 9/2/2021 20:21:07 | SK9ACT2 | 07 | Electric | ltron C2SRD | |||||||||||||||||||||||
73 | 9/6/2021 9:10:08 | R7PEG1R1S6 | 0000000 | Electric | I don't see a clear ERT type, please check it: https://i.imgur.com/MP6B4o7.png | G5 Integrated FOCUS AXe | ||||||||||||||||||||||
74 | 9/6/2021 9:15:06 | ows-nic531-06 | 13 | Electric | c2sl | |||||||||||||||||||||||
75 | 9/25/2021 23:25:11 | SK9AMI7 | 14 | Electric | This is a net meter with a PV system and I can get the SCM+ messages for the consumption from the grid. Can't figure out how to get the production value going back to the grid when the PV is overproducing. The consumption counter from the grid just plateaus (never goes down) when the PV is overproducing. | C2SO | ||||||||||||||||||||||
76 | 11/19/2021 23:48:41 | EO940GN-1 | 03 | Water | https://fcc.io/EO940GN-1, freq: 910-920MHz, confusingly the "50W" model number is in small print and in large print is "ERW 1008 506" which is like a "sub-model" number indicating a variation for the particular physical meter it is mounted to | Itron 50W | ||||||||||||||||||||||
77 | 11/19/2021 23:50:30 | EWQ100GDLAN | 12 | Gas | https://fcc.io/EWQ100GDLAN | Itron 100G | ||||||||||||||||||||||
78 | 11/21/2021 17:44:55 | F9CC1R-1 | 04 | Electric | Schlumberger C1SR | |||||||||||||||||||||||
79 | 1/4/2022 21:00:16 | CDT5XESS | 07 | Electric | iTron I-210+ | |||||||||||||||||||||||
80 | 1/21/2022 14:23:42 | EWQ500GA | 12 | Gas | SCM+ it appears, 10 digit unique identifier. | Itron GEN5 500G | ||||||||||||||||||||||
81 | 2/20/2022 10:38:34 | SDBIDTB001 | 04 | Electric | Sensus iCon iSA2 with Flexnet 530X Smart Meter | iSA2 | ||||||||||||||||||||||
82 | 3/24/2022 17:16:40 | R7PER6R1S2 | 02 | Gas | I am not confident I got the ERT Type correct. | Landis+Gyr Gridstream 120M-1 | ||||||||||||||||||||||
83 | 4/7/2022 13:56:49 | F9CC1R-1 | 04 | Electric | I think this is a pre-Itron acquisition C1SR. Looks nearly identical but FCC-ID is different though. | Schlumberger C1SR | ||||||||||||||||||||||
84 | 4/19/2022 9:58:29 | SK9C1A-3B | 07 | Electric | Protocol is SCM+ | Itron C1SR | ||||||||||||||||||||||
85 | 4/19/2022 19:56:23 | EWQINTELISG | 220 | Gas | SCM+:{ProtocolID:0x1E EndpointType:0xDC EndpointID: #### Consumption: 95309 Tamper:0x0B00 PacketCRC:0x####}} | Itron ERG-7100-005 | ||||||||||||||||||||||
86 | 5/2/2022 16:11:18 | CDT5XESS | 07 | Electric | Itron 5XESS | |||||||||||||||||||||||
87 | 6/25/2022 22:39:18 | EWQ500GA | 30 | Gas | Itron Openway RIVA 500G ERT | |||||||||||||||||||||||
88 | 6/27/2022 22:44:35 | Unsure | 00 | Water | rtlamr successfully reads my water meter but the meter does not have a FCC ID or ERT listed. | Neptune MACH10)R900i v4 | ||||||||||||||||||||||
89 | 7/10/2022 13:00:02 | EWQ100GDLAS | 12 | Gas | According to Itron docs, DLT == DLS hardware using SCM, rather than SCM+ used by DLS | Itron 100G DLT | ||||||||||||||||||||||
90 | 10/2/2022 20:54:14 | SK9G5R1 | 04 | Electric | I don't think it is reading my meter data yet, I have not seen my Serial Number pop up. I have a net meter for my solar. | Itron R2SID | ||||||||||||||||||||||
91 | 10/21/2022 13:05:13 | SK9C1A-3 | 07 | Electric | Northwestern Energy in Billings, Montana Set in NET Metering Mode, Works GREAT! | Itron C1A-3 | ||||||||||||||||||||||
92 | 10/21/2022 13:19:23 | EWQ100GDLAS | 12 | Gas | Montana-Dakota Utilities (MDU) Billings, MT Installed 06/10/2018 | Itron 100G DLS | ||||||||||||||||||||||
93 | 10/21/2022 13:21:48 | P2SR900M | 11 | Water | City of Billings Water Works Mfg. 10/10/2018 | Neptune R900 V4 | ||||||||||||||||||||||
94 | 10/24/2022 15:27:04 | Landis+Gyr | 07 | Electric | Landis+Gyrl | |||||||||||||||||||||||
95 | 11/8/2022 10:50:07 | OZFACXX20 | 00 | Electric | jake541@gmail.com | Intron C2SD | ||||||||||||||||||||||
96 | 11/8/2022 11:15:16 | OZFACXX20 | 12 | Electric | Corrected submission - jake541@gmail.com - https://imgur.com/a/wbnfuaO | Itron C2SD | ||||||||||||||||||||||
97 | 1/16/2023 9:23:15 | R7PEG1R1S5 | 05 | Electric | Could not find ERT type; Module Model: G5 26-1905; 50D3B0F9; | Landis+Gyr (Gridstream RF) Focus AXRe-SD | ||||||||||||||||||||||
98 | 2/27/2023 16:12:24 | unknown | 00 | Electric | Trilliant meters use zigbee secure | Trilliant | ||||||||||||||||||||||
99 | 5/20/2023 8:52:39 | EWQ100GDLAS | 12 | Gas | 100GDLAS | |||||||||||||||||||||||
100 | 5/24/2023 23:56:26 | qzc-rx2ea4f | 41 | Electric | elster r2sd |