ABCDEFGHIJKLMNOPQRSTUVWXY
1
Work Order
DescriptionStatusWo Priority
Work Type
Scheduled FInishKeterangan
2
WO19388#00 Sail Lamp SU B AbnormalINPRGNORMALCM5/18/24 1:47 PMJOBCARD BALIK TGL 27/08/2024
3
WO20130#00, Gantry Crane CWP Outdoor Tidak Dapat DioperasikanAPPRNORMALCM2/29/24 3:01 PMKTB168 PENGADAAN GANTRY CRANE SET - PLN SC COLAB PT JPC (PROSES PEMBONGKARAN & PEMASANGAN GANTRY CRANE - EST OKTOBER 2024 SELESAI)
4
WO20605
#00, Common, CCTV POS security depan pintu keluar utama motor rusak
WMATLNORMALCM1/31/24 7:14 AM
5
WO20606#00, Common, CCTV pos security bawah rusakWMATLNORMALCM1/31/24 7:19 AM
6
WO20607#00, Lampu Area C1 Mati 5 BuahWJOBCARDNORMALCM
12/18/23 12:50 PM
1/18/24 12:50 PM
7
WO20753#00, Common, lampu underground conveyor 4 matiWJOBCARDNORMALCM12/12/23 13:0012/31/23 1:00 PM
8
WO20852#00 Tripper 2E Feedback FailureWJOBCARDNORMALCM12/12/23 13:0312/31/23 1:03 PM
9
WO21070#00 Slewing SR abnormalWJOBCARDNORMALCM
12/14/23 2:16 PM
12/31/23 2:16 PM
10
WO21964#20 Over head crane BFP tidak bisa dioperasikanWJOBCARDNORMALCM
12/19/23 3:16 PM
1/19/24 3:16 PM
11
WO21972#00, Lampu Ruang MCC WTP MatiWJOBCARDNORMALCM
12/21/23 2:36 PM
1/21/24 2:36 PM
12
WO21987#10, UAT Motor Fan Cooling no. 3 putaran beratWJOBCARDNORMALCM
12/23/23 5:13 AM
1/23/24 5:13 AM
13
WO22036#00 Temperature ruangan compressor dan DCS ESP panas 44.4CWJOBCARDNORMALCM
12/28/23 5:17 AM
1/28/24 5:17 AM
14
WO22043#20 FAN nomor 4 Trafo eksitasi #2 failureWUNSHUTNORMALCM
8/19/24 8:00 AM
10/2/24 16:30JOBCARD SUDAH BALIK
15
WO22195#00, Lampu Gudang MatiWJOBCARDNORMALCM2/29/24 7:08 AM
16
WO22217#00 Common Perlu cctv untuk pengawasan sampling batubaraWMATLNORMALCM2/15/24 1:55 PM
17
WO22218#00 Common Perlu cctv untuk pengawasan preparasi batubaraWMATLNORMALCM2/15/24 1:57 PM
18
WO22741#00,Common,vibrator sample divider tidak berfungsiWJOBCARDURGENTCM1/19/24 12:53 PM
19
WO22756#00, Common, Lampu ruangan belakang layar CCR matiWJOBCARDNORMALCM
1/16/24 9:04 AM
2/16/24 9:03 AMJOBCARD BALIK TGL 27/08/2024
20
WO22945#00,Common,CHCB,Lampu tangga C3 MatiWJOBCARDNORMALCM
1/16/24 9:09 AM
2/16/24 9:09 AMJOBCARD SUDAH BALIK
21
WO23071
#00,Common,CHCB,Speed detector belt conveyor C2 rusak pada roda
WJOBCARDNORMALCM2/1/24 9:113/31/24 9:11 AMJOBCARD SUDAH BALIK
22
WO23073
#00,Common,CHCB,Speed detector belt conveyor C3 rusak pada modul
WJOBCARDNORMALCM2/1/24 9:153/31/24 9:15 AMJOBCARD SUDAH BALIK
23
WO23126#00, CHCB, CCTV CHCB lost connectionWJOBCARDURGENTCM
1/22/24 3:24 PM
1/28/24 3:23 PM
24
WO23176#00,Common,CHCB,SR trip ( mati total )WJOBCARDNORMALCM
1/29/24 2:19 PM
2/29/24 2:19 PMJOBCARD SUDAH BALIK
25
WO23639#00 Lampu penerangan jalan arah gudang tidak menyalaWJOBCARDNORMALCM2/29/24 9:35 AM
26
WO23843Vibrasi pada Coal Feeder 2AWJOBCARDNORMALPDM
1/23/24 10:15 AM
2/17/24 10:15 AMJOBCARD SUDAH BALIK
27
WO23844Vibrasi pada Motor Coal Feeder 2CWJOBCARDNORMALPDM
1/23/24 10:19 AM
2/17/24 10:19 AMJOBCARD SUDAH BALIK
28
WO23845Vibrasi pada Motor Coal Feeder 2FWJOBCARDNORMALPDM
1/23/24 10:22 AM
2/17/24 10:22 AMJOBCARD SUDAH BALIK
29
WO23933#10, Lampu Coal Feeder 1A sisi Inlet dan Outlet PadamAPPRNORMALCM3/12/24 10:24
30
WO23934#10, Lampu Coal feeder 1C Sisi Inlet dan Outlet PadamAPPRNORMALCM3/12/24 10:29
31
WO23935#10, Lampu Coal Feeder 1D sisi inlet dan outlet PadamAPPRNORMALCM3/12/24 10:31
32
WO24139#00, Sensor Belt Strap Avulsion Conveyor 5A tidak terpasangAPPRNORMALCM
2/19/24 7:09 AM
3/19/24 7:09 AMJOBCARD SUDAH BALIK
33
WO24140#00, Sensor Belt Strap Avulsion Conveyor 5B tidak terpasangWJOBCARDNORMALCM
2/19/24 12:30 PM
3/19/24 12:30 PMJOBCARD SUDAH BALIK
34
WO24141#10,Boiler,Sump Pump Underground BAS RusakWJOBCARDNORMALCM
2/19/24 12:41 PM
3/19/24 12:41 PMJOBCARD SUDAH BALIK
35
WO24855#00, Chiller sampling rack tripAPPRNORMALCM3/31/24 9:55 PM
36
WO24859#20 Bucket dan scraper 2B trip dan loss powerWJOBCARDURGENTCM
2/26/24 9:41 PM
3/3/24 21:41JOBCARD SUDAH BALIK
37
WO24866#00 Breaker C01B AbnormalWJOBCARDNORMALCM3/4/24 21:463/31/24 9:46 PMJOBCARD SUDAH BALIK
38
WO24869#00, Air Dryer Ash Handling A TripAPPRNORMALCM3/31/24 1:28 PM
39
WO25300#00, blower lemari asam lab air abnormalWMATLNORMALCM4/11/24 5:11
40
WO25309#20, Lampu area LPH 4 mati 2 buahWJOBCARDNORMALCM5/18/24 5:15 AM
41
WO25353#00 pintu rolling door compresor arah laut tidak bisa dioperasikanWJOBCARDNORMALCM
4/24/24 12:46 PM
5/18/24 5:34 AMJOBCARD SUDAH BALIK
42
WO26183#20 Teflon coupling turning gear #2 PecahAPPRURGENTCM3/13/24 6:56 AM3/19/24 6:56 AMJOBCARD SUDAH BALIK
43
WO26198#10, Lampu Penerangan Area Coal Feeder Sisi Dinding PadamAPPRNORMALCM
3/18/24 10:59 AM
4/18/24 10:59 AMJOBCARD SUDAH BALIK
44
WO26203#00, Common, Suara telpon dipatcher noiseAPPRNORMALCM6/25/24 7:17 AM
45
WO26206#10,Boiler,Sootblowing Alarm Power LoseAPPRNORMALCM3/17/24 7:13 AM4/17/24 7:13 AMJOBCARD SUDAH BALIK
46
WO26349#00, Pemisahan Power Listrik Pompa Kolam AdminAPPRNORMALCM4/25/24 8:48 AM
47
WO26415#00, Fan Pompa CIP RusakAPPRNORMALCM4/30/24 1:18 PM
48
WO26559#00 Breaker dry fly ash abnormalWJOBCARDURGENTCM3/27/24 1:47 PMJOBCARD BALIK TGL 27/08/2024
49
WO26562#00, Instalasi lampu penerangan ruangan OPHAR lantai 2 tripAPPRNORMALCM
3/20/24 12:47 PM
4/20/24 12:47 PMJOBCARD SUDAH BALIK
50
WO27112#00, Terjadi kondensasi pada dryer ash handling BAPPRNORMALPAM4/30/24 11:59 AM
PEKERJAAN BERLANGSUNG (M3 JULI 2024) OLEH PT PRIMA ORBIT
51
WO27121#00 Vibrator rotary sample devider abnormalWJOBCARDNORMALCM4/5/24 9:415/5/24 9:41JOBCARD SUDAH BALIK
52
WO27572#20 sambungan line outlet sumppump pit oil unit #2 abnormalAPPRNORMALCM4/30/24 9:45 AM
53
WO27579#20 PDC Trafo MCC CWP #2 Sering TripWJOBCARDNORMALCM4/5/24 10:535/5/24 10:53JOBCARD SUDAH BALIK
54
WO27585#00 MCB ruangan CHCB abnormalWJOBCARDNORMALCM4/5/24 10:495/5/24 10:47JOBCARD SUDAH BALIK
55
WO27902#00, Motor Bag Filter Fly Ash Silo B NoiseWJOBCARDNORMALCM5/22/24 3:16 PMJOBCARD BALIK TGL 27/08/2024
56
WO27904#00, Conveyor 5B Sering Trip Alarm Skid 1 dan 2WJOBCARDNORMALCM4/11/24 13:075/11/24 13:07JOBCARD SUDAH BALIK
57
WO27905#20 Noise pada GSC Fan 2BAPPRNORMALCM5/22/24 3:18 PM
58
WO27906#20 Breaker Scrapper Coal Feeder 2A AbnormalWJOBCARDURGENTCM
4/14/24 1:02 PM
JOBCARD SUDAH BALIK
59
WO27928#00,Common,Saklar blower laboratorium batubara perlu digantiWJOBCARDNORMALCM
4/22/24 3:08 PM
JOBCARD SUDAH BALIK
60
WO27929#00, Pompa blowdown not readyAPPRNORMALPAM5/22/24 3:03 PM
61
WO28098#00,WWTP,Shaft Mixer Coagulant LepasWJOBCARDNORMALCM
4/29/24 9:34 AM
5/29/24 9:34 AMJOBCARD SUDAH BALIK
62
WO28226
#00,Lab Sampling Batubara, RSD(Rotary Sieve Devider) Besar Nyetrum
WJOBCARDNORMALCM
4/26/24 9:36 AM
5/26/24 9:36 AMJOBCARD SUDAH BALIK
63
WO28330#00 Lifting Down Ship Unloader A sering tripAPPRNORMALCM5/31/24 2:29 PMJOBCARD BALIK TGL 5/09/2024
64
WO28570#00 vibrator sample tdk berfungsiAPPRURGENTCM5/6/24 12:18
65
WO28722
#10 Sensor alarm Generator Transformator Fan II Power Fault Rusak
APPRNORMALCM5/31/24 2:38 PM
66
WO29139#00 Roling door kompressor building tidak dapat di operasikanAPPRNORMALCM6/20/24 3:15 PM
67
WO29141#00 lampu chlorine mati buildingAPPRNORMALCM6/15/24 3:25 PM
68
WO29149#10 lampu jalan rusak / lepas lampunyaAPPRNORMALCM6/15/24 3:22 PM
69
WO29157
#10 Lampu Penerangan Area Boiler Unit #1 banyak yang tidak berfungsi
APPRNORMALCM6/15/24 3:20 PM
70
WO29158#10 Purifier MOT alarm Heater OverheatAPPRNORMALCM6/15/24 10:29 AM
71
WO29267#00, Lampu Area Parkir Mobil Gedung Admin Banyak Yg PadamAPPRNORMALCM6/20/24 12:22 PM
72
WO29268#00, Kontaktor Main Compressor B BerderikAPPRNORMALCM6/9/24 12:40
73
WO29269#00, Motor Traveling Stacker Reclaimer No.216 Short CircuitWJOBCARDNORMALCM
5/20/24 12:48 PM
6/20/24 12:48 PMJOBCARD SUDAH BALIK
74
WO29436#20 Indikator Generator Transformator Oil Temperatur ErrorAPPRNORMALCM6/20/24 7:28 AM
75
WO29437#20 Indikator auxiliary transformator oil temperature ErrorAPPRNORMALCM6/20/24 9:31 AM
76
WO29438#20 Indikator auxiliary transformator oil temperature 2 ErrorAPPRNORMALCM6/20/24 9:26 AM
77
WO29453Portable compressor mekanik 2 soket power rusakAPPRNORMALPAM5/31/24 3:18 PMPERLU IDENTIFIKASI LANJUT
78
WO29458#10, Temp Winding CWP 1B Indikasi HighWJOBCARDNORMALCM5/31/24 10:48 AMJOBCARD BALIK TGL 27/08/2024
79
WO29459#00, Lifting up Ship Unloader B AbnormalAPPRNORMALCM6/17/24 10:25 AMPERLU IDENTIFIKASI LANJUT
80
WO29475#00 Kabel teleskopik chute FAS A terdapat percikan apiAPPRNORMALCM6/20/24 10:28 AMPERLU IDENTIFIKASI LANJUT
81
WO29884#00, DG Ship Unloader B tidak Bisa Dioperasikan Mode RemoteWJOBCARDNORMALCM6/3/24 13:106/30/24 1:10 PMJOBCARD SUDAH BALIK
82
WO29895#00, Mixer FLy Ash Silo B Tidak Bisa BeroperasiWJOBCARDNORMALCM6/28/24 7:11 AMJOBCARD BALIK TGL 27/08/2024
83
WO29896#10, Bearing Tile Turbin No. 6 Turbin temp HighWJOBCARDNORMALCM6/15/24 7:20 AM
PEKERJAAN SELESAI 2 JUNI 2024 (RECOVERY #1 25 MEI - 9 JUNI 2024)
JOBCARD BALIK TGL 27/08/2024
84
WO29899
#00 Boom Ship Unloader A Sisi Laut Kurang Penerangan Pada Malam Hari
APPRNORMALCM6/30/24 7:07 AMPERLU IDENTIFIKASI LANJUT
85
WO29900
#00 Boom Ship Unloader B Sisi Laut Kurang Penerangan Pada Malam Hari
APPRNORMALCM6/30/24 7:09 AMPERLU IDENTIFIKASI LANJUT
86
WO30249#00,Common,CCTV area jetty matiAPPRNORMALCM6/30/24 7:14 AMPERLU IDENTIFIKASI LANJUT
87
WO30252#10 Breaker lampu area coalfeeder #1 short circuitWJOBCARDNORMALCM6/30/24 1:13 PMJOBCARD BALIK TGL 27/08/2024
88
WO30276#00,Common,SU,Panel pompa air limbah tidak berfungsiAPPRNORMALCM6/30/24 7:11 AMPERLU IDENTIFIKASI LANJUT
89
WO30418#10 Unit1 Penunjukan Arus AC oil pump errorWJOBCARDURGENTCM6/9/24 14:01JOBCARD BALIK TGL 27/08/2024
90
WO30651#10 Rembesan oil Turbin di bearing 5 Unit #1APPRNORMALCM7/10/24 10:27PERLU IDENTIFIKASI LANJUT
91
WO30660vibrasi pada motor LP drain pump #1WJOBCARDNORMALCM7/13/24 10:04 AMPEKERJAAN SELESAI & TES VIBRASI 14 JUNI 2024
JOBCARD BALIK TGL 27/08/2024
92
WO30666#00, Common, Pompa celup low pressure untuk support drain FAWJOBCARDNORMALCM7/10/24 10:19JOBCARD BALIK TGL 27/08/2024
93
WO30667#10, Boiler, Alarm shell shift active slag cooler 1BWJOBCARDNORMALCM7/7/24 10:26JOBCARD BALIK TGL 27/08/2024
94
WO30671
#00,Electric CEMS,Request Penambahan Power untuk Panel PLC DIS CEMS
WJOBCARDNORMALCM7/7/24 10:30JOBCARD BALIK TGL 27/08/2024
95
WO30678#00, Conveyor 01A Alarm slight Off SetWJOBCARDNORMALCM
6/19/24 10:34 AM
7/19/24 10:34 AMJOBCARD SUDAH BALIK
96
WO30777#20, Skun Kabel LP Drain Pump KendorWJOBCARDURGENTCM6/17/24 4:00 PMJOBCARD BALIK TGL 27/08/2024
97
WO30952Vibrasi C3WP 1AWJOBCARDNORMALCM6/30/24 11:00 AMJOBCARD BALIK TGL 27/08/2024
98
WO30953Vibrasi motor ID Fan 1AWJOBCARDNORMALCM6/30/24 11:00 AMJOBCARD BALIK TGL 27/08/2024
99
WO30954#00 lampu office eng - har matiAPPRNORMALCM7/19/24 8:52 AMPERLU IDENTIFIKASI LANJUT
100
WO31391#10, Penambahan transducer current pada coal feeder unit 1APPRNORMALCM7/14/24 9:22 AM