ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
How much experience/exposure to simc do you have?
simc experience notwithstanding, how much coding experience do you have?
How would you value (on a 1-10 scale, with 10 being the most valuable and 1 the least) the following features of an updated version of simc:

a. running speed (i.e. how fast the code executes)
b. new detector/spectrometer development speed (i.e. how easy/fast it is to implement a new detector in simc)c. speed of adding new reactions of interest to the existing pool of final states already implementedd. on-boarding speed (i.e. how easy/hard it is to get new simc users (students, postdocs w/o Hall A/C experience, etc.) up and running):How satisfied are you with the existing simc documentation? (5 = very satisfied, 1 = not so much)If you think that you might help the effort of producing a new (& improved) version of simc, what roles do you see yourself in?Please leave any suggestion or comment you have about the SIMC
2
1-5 years5-10 years95342testing the code and its output, updating the code for a specific detector a/o spectrometer
3
1-5 years5-10 years104781implementing new reactions of interest, testing the code and its output
4
20+ years20+ years867102implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometer, updating the radiative corrections portions of the code
5
5-10 years5-10 years81010101testing the code and its output, Would I also be able to involve my grad/or REU students? (or perhaps is only for people with a certain level of experience in coding)Would I also be able to involve my grad/or REU students? (or perhaps is only for people with a certain level of experience in coding)
6
1-5 years5-10 years48852testing the code and its output, updating the radiative corrections portions of the code, Organizing the data used for modeling cross sections for both human readability and machine actionability. I personally prefer the use of python, but I strongly recommend the user experience is central to the development no matter what language that is chosen. This means a standard input definition through a standard format like YAML, JSON, etc. not a custom input. I strongly recommend we target container deployment and a web based service to allow users to simply submit standard jobs. I can help on that front. To support new detectors easily, we will need a modular package, and likely a plugin style architecture. These require software engineering principles like dependency inversion and strongly typed classes / methods. To physicists who have programmed for many years, these methods may look complex. We need to considerate what is good complexity and bad complexity throughout the development process
7
1-5 years10-20 years7101073sorry I cannot help with this effort (no problem, thanks for answering!)Thanks for taking on these efforts. I think it would be amazing to have simc in C++ in order to match with geant4, especially for adding new experimental set ups or detectors, much of the time this is already coded in geant4 elsewhere.
8
5-10 years5-10 years59971testing the code and its output, updating the code for a specific detector a/o spectrometer
9
1-5 years1-5 years81010101testing the code and its output, updating the code for a specific detector a/o spectrometerIn my experience as a grad student, the "on-boarding" for new users is the most difficult part of SIMC as it is right now and the documentation is way too scarce and/or outdated. It'll be great if we could improve on that side.
10
10-20 years20+ years89992sorry I cannot help with this effort (no problem, thanks for answering!)
11
20+ years20+ years1101093testing the code and its output, updating the radiative corrections portions of the codeOnce the initial conversion is completed, we should also consider implementing the detector portion in Geant with its output processed by a hcana like analyzer.
12
1-5 years20+ years797104sorry I cannot help with this effort (no problem, thanks for answering!)It would be great to integrate single arm MC in an easier way than present.
13
5-10 years10-20 years799102implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometer
14
1-5 years5-10 years83892sorry I cannot help with this effort (no problem, thanks for answering!)
15
1-5 years5-10 years105852sorry I cannot help with this effort (no problem, thanks for answering!)The speed of SIMC is part of why Hall C can do analyses so rapidly compared to the other halls, so for me maintaining the speed (and accuracy) is probably most important.
16
20+ years20+ years108972implementing new reactions of interest, testing the code and its output1) The on-boarding speed would be greatly enhanced if there were SIMC tutorials, or other documentation to rely on. Right now, it's basically word of mouth.
2) I also encourage the working group to consider writing a Computer Physics Communications article on SIMC, as there is no good reference to cite when publishing Hall C results. The article could profile the most important aspects of SIMC, and show the level of agreement between data and MC, particular for coincidence spectrometer acceptances and magnetic optics effects. Many years ago, John Arrington made a very nice presentation comparing the level of agreement SIMC gave for the Hall A spectrometers, compared to the standard Hall A MC in use at the time, the difference was significant.
17
1-5 years1-5 years1010861testing the code and its output, updating the code for a specific detector a/o spectrometerC++ should be the language of use, natural connection to ROOT and Geant4. Perhaps a front end in other language, but not the core.
18
20+ years20+ years35552testing the code and its outputMainly interested in SIDIS, exclusive pions (including pi0), and the pi-Delta final state. Also optics for SHMS. I currently use SIMC quite extenisively for RSIDIS and NPS experiments.
But, I'm getting close to full retirement.
19
10-20 years1-5 years53162implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometerThis is a very timely effort, thank you for lead the effort Sanghwa! You have my full support!
20
1-5 years10-20 years71010103implementing new reactions of interest, testing the code and its output, Help with development of interface to g4sbs.The most important things for me personally (as someone fairly new to simc) are:
- Better and up-to-date documentation.
- Moving away from fortran, as that is one of the least user friendly languages I have used.

I'm now actively developing a new framework within simc, so I'll be happy to help with these improvements.
21
1-5 years1-5 years571071testing the code and its output
22
5-10 years10-20 years7101051implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometer, documentation!!!!
23
None10-20 years1079103implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometer
24
5-10 years10-20 years791083implementing new reactions of interest, testing the code and its output
25
5-10 years10-20 years610992sorry I cannot help with this effort (no problem, thanks for answering!)
26
1-5 years5-10 years74893implementing new reactions of interest, testing the code and its outputAs we discussed in the first meeting, it would be good to find a way to merge the single-arm version of SIMC with the standard version. This effort would overlap with the effort mentioned above to add additional reactions of interest.

One other thing that would be useful is additional output variables in the standard SIMC output ROOT file. For example, we write the generated and reconstructed quantities in the spectrometer (target) coordinate system. But, as far as I see, we don't directly calcuate the reconstructed global z-vertex (which is mostly a function of target-y and the central angle, but also depends on y-prime and measured beam position). Since experiments sometimes make software cuts on the global reaction coordinates, this would be useful to add.

Lastly, if I run SIMC with an LH2 target, for example, I see that the upstream window is taken into account for the external radiative effects (and I guess beam ionization energy loss). But scattering events aren't generated in the target windows themselves. For cryo/gas targets, it would be nice to think about whether events can be generated in both the target and the windows in the same simulation run. This could be hard to implement, but maybe we can discuss it.
27
1-5 years1-5 years51010105sorry I cannot help with this effort (no problem, thanks for answering!)C++ is more convenient, thanks to its class structure. It makes creating a new process much easier than other languages, additionally can import Geant4 libraries more easily.
28
1-5 years1-5 years55412sorry I cannot help with this effort (no problem, thanks for answering!), implementing new reactions of interest, testing the code and its output, updating the code for a specific detector a/o spectrometer, updating the radiative corrections portions of the codeMake it C++
29
5-10 years10-20 years910873testing the code and its outputImplement the code in C++
30
5-10 years10-20 years105793sorry I cannot help with this effort (no problem, thanks for answering!)It would be good to have it in C++ so one can interface with geant and one could also model detector responses in the future
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100