ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Design of Columns Under Axial Loads
2
3
Project:Jeddah Stadium Extension
4
Location:KSA
5
6
Frame:Frame No ( )
7
Column:Column on Axis (H-3)
8
9
Data
10
Column Loads:Pu =2000KN
11
Qu =208KN
12
13
MaterialsSteel Fy =280MpaFu=520Mpa
14
15
Column Buckling LengthLx=6mKx=1Lbx= 6m
16
Ly=6mKy=1Lby=6m
17
Lz=6mKz=1Lbz=6m
18
19
Proposed Column Dimensions
Overall web depth d =
320mmProprties of section
20
Web thick tw = 11,5mmA=15508,5mm2Cw=2068712015625mm6
21
Flange Width bf=300mmIx=296641006,1mm4rx=138,3027117mm
22
Flange thick tf=20,5mmIy=92250000mm4ry=77,12555286mm
23
Clear web depth dw =
238mmJ=1885063,142mm4
24
25
Local Buckling
26
Flange lf=7,317073171 lp=9,143498861 lr=16,73320053Compact
27
Web lw=20,69565217 lp=34,66162967 lr=38,2473155Compact
28
Effective flange be=
300mm
29
Effective Web de=
279mm
30
Effective area Ae
15508,5mm2
Effective Area Factor (Q)=
1
31
Results
32
Flexural Buckling
33
lx =43,3830973
34
ly =77,79522839
35
Fe=342,4625765N/mm2
36
Torsional Buckling
37
Ft=697,4342725N/mm2
38
39
Column Strength
40
lc =0,9042165584
41
lc *Q=0,9042165584
42
Fcr=192,0908325N/mm2
43
44
fc*Pn=0.8*Fcr*A=2383,232541KN
45
46
Then the Column Ultimate Capacity is2383,232541KN
47
48
Stress Ratio =0,8391963293Safe and Economic
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100