5.3 Tystar3 - 3GATEOXA
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

View only
 
 
ABCDEFGHIJKLMN
1
2
Tystar3- 3GATEOXA
3
4
Process Specification
Process Performance
5
Tool Name:Tystar3
6
Description: This monitor tracks oxide thickness and non-uniformity, RI, minority carrier surface lifetime.
7
8
Recipe:3GATEOXA
9
Layer Material: Oxide
10
11
12
Targeted Results:
13
TargetDescription
14
Thickness [A]:300
15
16
Non-uniformity [%]:<5Calculated using (MAX-MIN) / (MAX+MIN) method on thickness data.
17
18
19
Process Conditions:
20
Oxidation:
21
O2 [sccm]:9000
22
Temperature [degrees C]:
950
23
Time [HH:MM:SS]:00:45:00
24
25
Anneal:
26
N2 flow [sccms]: 9000
27
Temp [degrees C]950
28
Time [HH:MM:SS]:00:20:00
29