Signups for Fan Coil ReplacementOriginal SpecOrig. SpecOriginally Installed"HHX" instead of "HH" is ECM
2
UnitOwnerCompletedCoil #GPMCoil #New Coil NumberRegistersCFM / RegisterNOTES
3
Done101Art Klipfel10/1/202416MB616MBHAS BYPASS
4
Done102John and Marianne Nelson3/1/202516MB616MBRepiped only, bypass added
5
Done103Nick and Katie8/1/202516MB616MB
6
Done104Mark Ostow8/1/202510HH-4610HH5-240-4RH10hh5-240-4rh
7
Done105Ira6/24/20236HH-456HHS4-240-3 LH6hhs-240-4
8
Done106Ben Benjamin9/1/20248HH-46.5
6HHS-3? 8HH5-240-4RH
8hh3x-208-4 rh
9
Done107Bob Cowherd8/1/20256HH-456HHS-3?2025 configuration, 2 way valve, eliminated bypass
10
Done108Felix - Specialized Housing10/7/20246HH-454HH3X-208-4 rh
11
Done208Lindsey20196HH-35This one is done. It has the zone valve.
12
Done308Kasell10/1/20236HH-448HH3X-208-4 RH?
13
Done109Felix - Specialized Housing10/14/20244HHS-424HH3X-208-4 rh
14
Done209John MacDougall5/15/20246HHS-428HH3X-208-4 RH
15
Done309Koffman12/1/20236HH-358HH3X-208-4 RH?
16
Done210Clawson/Jaikumar3/1/20246HH-358HH3X-208-4 RH9 rooms
17
Done310Tonachel11/1/20236HH-358HH3X-208-4 RH8 rooms
18
Done410Jean Mason20188HH-458hh3-208-4rh
19
Done211Joan's old / Mary Ann Clawson6/15/20184HHS-31.54hhs3-240-4
20
Done311Elaine Hawley's old unit9/23/20184HHS-31.54hhs-240-4
21
Done411Francie (Cambridge Affordable)7/24/20204HHS-31.54hhs3-240-4
22
212Bill Huber20144HHS-422025 inspection: piping is 2 way valve, hayes flow control.
23
Done312Clark/Bewig2/15/20244HHS-424HHS3X-208-4 RH4 rooms
24
Done412Robin5/1/20244HHS-426HH-4RH4HH3X-208-4 rh
25
Done114Foritano3/1/20244HHS-426HH3X-208-4 RH6100
26
Done214 Wassel5/1/20244HHS-426HH3X-208-4 RH6100
27
Done314Hawley5/1/20246HH-346HH3X-208-4 RH6100original spec should have given this unit less GPM
28
Done414Helfman4/1/20246HH-326HH3X-208-4 RH6100original spec should have given this unit MORE GPM
29
Done115Ninian Stein11/30/20224HHS-426hh3x-208-4 rh
30
Done215Haddad10/1/20246HH-328HH3X-208-4 RH7 rooms
31
Done315Dan Watts5/14/20236HH-346hh3x-208-4 rh
32
Done415Margolis4/1/20246HH-346HH3X-208-4 RH6 rooms
33
Done116Brown/Li10/28/202416MB616MB…
34
Done117Richard Curran8/1/202516MB616MB2025 Repiped to 2 way zone valve, hayes flow control
35
Done118Melvin4/1/202416MB616MB…
36
Done119Cambridge Affordable9/1/20244HHS-426hh3x-208-4 rh4
37
?219David Brenner4HHS-426hh3x-208-4 rh
38
319Jan DeKenis4HHS-42.56hh3x-208-4 rh
39
Done120Ileana Jones
2014 install, 2025 repipe
6HHS-45Unit repiped 2025
40
?piping config
220Gwen Frankfeldt, Phil Olenick6HH-34Replaced twice
41
Done320Sanford/Attwood3/15/20246HH-356HH3-240-?RH6HH3X-208-4 RH6 rooms
42
Done121Michael M12/18/202416MB616MBHAS BYPASS
43
Done122Joe Sternfeld10/16/202416MB616MBHAS BYPASS
44
45
46
Common Area Units
47
DoneFC-01
Srv Din/Kid rm, Loc Grg Vestibule
6/30/20246HH3X-208-4 RH
48
DoneFC-02Srv Craft Rm, Loc Craft Rm5/15/20244HHS3X-208-4 RH
49
FC-03
Srv Liv Rm Kitch, Loc Elect Rm
7/1/20248HH3X-208-4 RH
50
DoneFC-04
Srv Rec rm/bath, Loc Bsmnt Bath
6/15/20248HH5X-208-4 RH
51
DoneFC-05
Srv Lib/Hall, Loc Rec Rm Vest near bk stairs
10/28/20246HH3X-208-4 RH
52
DoneFC-06
Srv Office/hall, Loc Str Rm off spine
6/15/20244HHS3X-208-4 RH
53
DoneFC-07
Srv Guest Rm Ste, Loc Guest Rm Foyer
6/1/20244HHS3X-208-4 RH
54
FC-08Srv EE Bsmnt, Loc EE Bsmnt6/30/20248CHH3X-208-4 RHWant enclosed version