ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Schedule - List - 2927 W Pikes Peak Ave (exported on Jul 22, 2026)
2
ID #TitleCompletePercent CompletePhaseDurationStartEndAssigned ToAcceptedPendingDeclinedPred 1 IdPred 1 TypePred 1 LagPred 2 IdPred 2 TypePred 2 LagPred 3 IdPred 3 TypePred 3 LagPred 4 IdPred 4 TypePred 4 Lag
3
1Schematic Design Phase 1 TRUE100257/11/20248/14/2024000
4
2Finalize Concept Site PlanTRUE10059/18/20249/24/2024000
5
3PCSA Payment 2 TRUE10019/24/20249/24/2024000
6
4Finalize BackgroundsTRUE100159/25/202410/15/20240002FS0
7
5Construction Documents DevelopmentTRUE1002310/16/202411/15/20240004FS0
8
6MEP EngineeringTRUE1002310/16/202411/15/20240004FS0
9
7Draft Development Site PlanTRUE1001011/4/202411/15/2024000
10
8Dig open Hole for Soil testTRUE100111/11/202411/11/2024000
11
9Perform soils testingTRUE100111/12/202411/12/20240008FS0
12
10Development Plan Review 1TRUE1001711/15/202412/11/202400015SS-16
13
11Civil Engineering TRUE1001511/18/202412/10/20240007FS0
14
12Landscape DesignTRUE100811/18/202411/27/20240007FS0
15
13PPRBD Submittal & ReviewTRUE1004011/18/20241/17/20250006FS05FS0
16
14Traffic Impact StudyTRUE1002312/10/20241/14/2025000
17
15Submit Development PlanTRUE100112/11/202412/11/202400011FS0
18
16Revise Development PlanTRUE1001012/12/202412/27/202400010FS0
19
17Resubmit Development PlanTRUE10011/2/20251/2/202500016FS2
20
18Development Plan Review 2TRUE100151/7/20251/27/202500017SS3
21
19Contract Review & SigningTRUE100233/24/20254/23/2025000
22
20Real Estate ClosingTRUE10016/11/20256/11/2025000
23
21Hazardous Materials Testing and resultsTRUE10086/12/20256/23/202500020FS0
24
22Mobilization And Subcontractor Contract WorkTRUE100366/12/20257/31/202500020FS0
25
23Safety Plan Meeting TRUE10016/12/20256/12/2025Cameron Wolf, Casey Copley, Lee Chapin00020FS0
26
24site walk w/ abatement companiesTRUE10046/25/20256/30/2025000
27
25Deposit City Assurance to DRE and Pull Permit TRUE10027/8/20257/9/2025Casey Copley000
28
26
Issue contract to QECS Abatement sub and schedule
TRUE10017/9/20257/9/2025Casey Copley000
29
27Abatement Permit Waiting PeriodTRUE100107/10/20257/23/2025000
30
28SHC Demo Mark-outTRUE10017/16/20257/16/2025000
31
29Construction MobilizationTRUE10017/21/20257/21/2025000
32
30Contract electrical & plumbing safe offTRUE10017/22/20257/22/202500031SS-1
33
31Safe Off Electric & PlumbingTRUE10047/23/20257/28/2025Strive Electric00033SS-4
34
32Abatement MobilizationTRUE10037/24/20257/28/2025000
35
33Hazardous material demoTRUE100437/29/20259/26/2025Quality Environmental Control Specialists (QECS)00027FS3
36
34Complete Irrigation PlanTRUE10058/5/20258/11/2025000
37
35Interior Demolition of Non Hazardous Materials TRUE100378/12/202510/2/2025Quality Environmental Control Specialists (QECS)00031FS0
38
36OC Meeting (PM & Clients)TRUE10018/13/20258/13/2025000
39
37Get Excavator Under ContractTRUE10018/26/20258/26/2025000
40
38Call In LocatesTRUE10019/17/20259/17/2025000
41
39Site/Exterior Demolition Phase 1TRUE100129/17/202510/2/202500033SS1437FS1434FS5
42
40Landscaping Demo TRUE10089/19/20259/30/202500035FS-10
43
41Contract exterior green lit subcontractorsTRUE10019/30/20259/30/202500057SS-20
44
42Fence Post Installation (Playground)TRUE10059/30/202510/6/2025Colorado Springs Fence Co000
45
43Roofing, Gutters & DownspoutsTRUE100109/30/202510/13/2025000
46
44Saw Cut Demo LayoutTRUE10019/30/20259/30/2025Casey Copley, Whitcomb Plumbing00035FS-3
47
45Curb, Gutter, Sidewalk, Footings TRUE1003010/1/202511/11/2025000
48
46Fence Post LayoutTRUE100110/1/202510/1/2025Casey Copley000
49
47SawcuttingTRUE100210/1/202510/2/202500044FS0
50
48Underground Rough PlumbingTRUE100610/7/202510/14/2025Whitcomb Plumbing00047FS239FS-2
51
49Exterior updating WorkTRUE100710/14/202510/22/2025000
52
50Confirm Project PricingTRUE1005310/15/20251/2/202600035FS833FS8
53
51Underground plumbing rough inspectionTRUE100110/15/202510/15/202500048FS0
54
52Backfill and PourbackTRUE100310/16/202510/20/202500051FS0
55
53Framing Materials DeliveryTRUE100110/21/202510/21/202500052FS0
56
54Efflorescence and french drain installTRUE1001110/24/202511/7/2025Colorado Water & Mold Restoration000
57
55Framing LayoutTRUE100210/24/202510/27/202500052FS3
58
56FramingTRUE1005610/28/20251/20/2026Pursuit of Excellence00055FS0
59
57Install Downspout Drainage TRUE100310/28/202510/30/2025G & K's Landscaping & Construction000
60
58Upper level box walk TRUE100111/10/202511/10/2025000
61
59Flatwork & RampTRUE1002611/12/202512/19/202500045FS0
62
60Order Windows ( 6 week lead time )TRUE1002612/5/20251/14/2026Davids window service000
63
61Slab Air Flow Testing for RadonTRUE100112/10/202512/10/2025000
64
62Asphalt repair and patch back TRUE100112/17/202512/17/202500045FS059FS-3
65
63Electrical box walk with client and electrician TRUE100112/17/202512/17/2025000
66
64Fencing Phase 1TRUE100612/18/202512/29/202500062FS0
67
65Backfill remaining slab in lower level TRUE100112/26/202512/26/2025000
68
66Framing scope walk with PinoTRUE10011/5/2026 2:00 PM1/5/2026 3:00 PMCasey Copley, Stephen Michaels000
69
67Rough ElectricFALSE75711/14/20264/22/2026
American Electrician, Colorado Water & Mold Restoration
00056FS-5
70
68Rough MechanicalFALSE751151/15/20266/25/2026Colorado Water & Mold Restoration00056FS-467SS0
71
69Rough PlumbingFALSE99561/15/20264/2/2026Whitcomb Plumbing00067SS1
72
70Window Demo & Replacement Exterior FALSE98121/19/20262/3/2026Davids window service00060FS2
73
71Roofing flashing repairTRUE10011/30/20261/30/2026CS Quality Roofing000
74
72Rough Data & SecurityFALSE96672/9/20265/12/202600067SS18
75
73City Tap and asphalt TRUE100592/25/20265/18/2026Thorp Excavation000
76
74Fire pipe submittal approval FALSE0653/2/20266/1/2026000
77
75Radon System installation phase 1 TRUE10053/2/20263/6/2026000
78
76Temporary Structural Framing + finish main framingTRUE10033/2/20263/4/2026000
79
77Demo foundation walls TRUE10023/4/20263/5/202600076FS-1
80
78Footing 2 saw cut and demoTRUE10013/6/20263/6/2026Amaya Concrete00077FS0
81
79Open Hole observation Footing 2TRUE10013/9/20263/9/202600078FS0
82
80Footing rebar TRUE10013/10/20263/10/202600079FS0
83
81Footing inspection TRUE10013/11/20263/11/2026Casey Copley, Stephen Michaels00080FS0
84
82Pour Footing 2 and cure time TRUE10053/12/20263/18/202600081FS0
85
83Set Steel Posts and Beams & Complete all Framing TRUE10053/26/20264/1/202600082FS5
86
84Receive new Ducting / StagingTRUE10013/30/20263/30/2026000
87
85Rough Plumbing InspectionTRUE10014/3/20264/3/202600069FS0
88
86City tap re startFALSE75454/23/20266/25/2026Thorp Excavation000
89
87Rough Electrical Inspection walls and floorTRUE10024/23/20264/24/202600067FS0
90
88Install Playground FootersTRUE100204/27/20265/22/2026Casey Copley000
91
89Additional Framing (Self Perform ) Chases & DoorsFALSE0224/29/20265/29/2026Casey Copley000
92
90Wall BackingTRUE100135/20/20266/8/202600069FS33
93
91Mechanical roof boot install WHTRUE10015/21/20265/21/2026Casey Copley, CS Quality Roofing000
94
92Fire wet system pre walkTRUE10015/27/20265/27/2026000
95
93Drywall pre walk 2 TRUE10015/28/20265/28/2026Casey Copley, Drywall Solutions Ltd000
96
94Radon System re connections TRUE10015/28/20265/28/2026000
97
95Shade Sail DesignFALSE0125/29/20266/15/2026000
98
96shade sail engineering site meeting 1pmTRUE10016/2/20266/2/2026Caleb Strickler, Casey Copley, Lee Chapin000
99
97Fire System Rough - In-Wall & CeilingFALSE0396/4/20267/29/202600074FS2
100
98Plumbing mop sink relocationTRUE10016/9/20266/9/2026Whitcomb Plumbing000