| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | BHARATI VIDYAPEETH COLLEGE OF ENGINEERING BV/FR/AA/001 | |||||||||||||||||||||||||
2 | PASCHIM VIHAR, NEW DELHI – 110063 Issue no.: 03 | |||||||||||||||||||||||||
3 | LESSON PLANNING (AY-2023-24) Date of Issue:15.01.15 | |||||||||||||||||||||||||
4 | Class: B.Tech Sem:First | |||||||||||||||||||||||||
5 | Dept.: Applied Sciences Name of Faculty:Dr.Ashu Soni,Ashima AIRAN | |||||||||||||||||||||||||
6 | 1. As per the academic schedule, total lectures available for teaching in complete semester 36*2=72 | |||||||||||||||||||||||||
7 | 2. Lectures are allotted for each topic as follows: | |||||||||||||||||||||||||
8 | Sr. No. | Topic Details | No. of Lectures Allotted | No. of Lectures taken | Reference Book Name With Chapter and page No. | Remarks of HOD | ||||||||||||||||||||
9 | ||||||||||||||||||||||||||
10 | Date | |||||||||||||||||||||||||
11 | ||||||||||||||||||||||||||
12 | Unit I DC Circuits:FROM BASIC ELECTRICAL ENGINEERING BY ABHIJIT CHAKRABARTI (AC), A TEXT BOOK OF ELECTRICAL SCIENCE BY J.B.GUPTA | |||||||||||||||||||||||||
13 | 1 | Passive circuit components, Basic laws of Electrical Engineering | 1 | CHAPTER NO.4 (AC) PAGE NO.180-181 | ||||||||||||||||||||||
14 | 2 | Temperature Resistance Coefficients. voltage and current sources, Series and parallel circuits | 1 | CHAPTERNO.4 (AC) PAGE NO.182-195 | ||||||||||||||||||||||
15 | 3 | power and energy, Kirchhoff’s Laws, Nodal & Mesh Analysis, | 1 | CHAPTER NO.4(AC) PAGE NO.196-216 | ||||||||||||||||||||||
16 | 4 | delta-star transformation | 1 | CHAPTER NO.4 (AC) PAGE NO.217-231 | ||||||||||||||||||||||
17 | 5 | superposition theorem | 1 | CHAPTER NO.4 (AC) PAGE NO.232-241 | ||||||||||||||||||||||
18 | 6 | Thevenin’s theorem | 1 | CHAPTER NO.4 (AC) PAGE NO.242-255 | ||||||||||||||||||||||
19 | 7 | Norton’s theorem | 1 | CHAPTER NO.4 (AC) PAGE NO.256-267 | ||||||||||||||||||||||
20 | 8 | maximum power transfer theorem | 1 | CHAPTER NO.4 (AC) PAGE NO.268-273 | ||||||||||||||||||||||
21 | 9 | Time domain analysis of first Order RC & LC circuits | 1 | CHAPTER NO.3 (J.B.GUPTA) PAGE NO. 118-135 | ||||||||||||||||||||||
22 | Unit II AC Circuits FROM BASIC ELECTRICAL ENGINEERING BY ABHIJIT CHAKRABARTI (AC), ALEXANDER SADIKU (A.SADIKU) | |||||||||||||||||||||||||
23 | 11 | Representation of sinusoidal waveforms, peak and rms values, phasor representation | 1 | CHAPTER NO. 5 (AC) PAGE NO.337-342 | ||||||||||||||||||||||
24 | 12 | real power, reactive power, apparent power, power factor | 1 | CHAPTER NO. 5 (AC) PAGE NO. 359-366 | ||||||||||||||||||||||
25 | 13 | Analysis of single-phase ac circuits consisting of R, L, C, RL, RC, RLC combinations (series and parallel) | 1 | CHAPTER NO. 5 (AC) PAGE NO.346-359 | ||||||||||||||||||||||
26 | 14 | Analysis of single-phase ac circuits consisting of R, L, C, RL, RC, RLC combinations (series and parallel) | 1 | CHAPTER NO. 5 (AC) PAGE NO.346-360 | ||||||||||||||||||||||
27 | 15 | resonance | 1 | CHAPTER NO. 5 (AC) PAGE NO.382-394 | ||||||||||||||||||||||
28 | 16 | Three phase balanced circuits | 1 | CHAPTER NO. 12 (A. SADIKU), PAGE NO. 504-508 | ||||||||||||||||||||||
29 | 17 | voltage and current relations in star and delta connections | 1 | CHAPTER NO. 12 (A. SADIKU), PAGE NO. 512-513 | ||||||||||||||||||||||
30 | 18 | voltage and current relations in star and delta connections | 1 | CHAPTER NO. 12 (A. SADIKU), PAGE NO. 512-513 | ||||||||||||||||||||||
31 | Unit III D. C. Generators & Motors FROM BASIC ELECTRICAL ENGINEERING BY ABHIJIT CHAKRABARTI (AC), Electrical Technolgy By B.L Thareja (BLT) | |||||||||||||||||||||||||
32 | 19 | Principle of operation of Generators | 1 | CHAPTER NO.9 (AC),PAGE NO.598-607 | 20/1/2023/ | |||||||||||||||||||||
33 | 20 | Principle of operation of Motors | 1 | CHAPTER NO.9 (AC),PAGE NO.611-616 | ||||||||||||||||||||||
34 | 21 | Speed Control of shunt motors | 1 | CHAPTER NO.9 (AC),PAGE NO.617-618 | ||||||||||||||||||||||
35 | 22 | Flux control, Rheostatic control, voltage control, Speed control of series motors | 1 | CHAPTER NO.9 (AC),PAGE NO.612-618 | ||||||||||||||||||||||
36 | 23 | Principle of operation of AC generator | 1 | CHAPTER NO. 37 (BLT), PAGE NO. 1401-1408 | ||||||||||||||||||||||
37 | 24 | Principle of operation of AC Motor | 1 | CHAPTER NO.10 (AC),PAGE NO.661-663 | ||||||||||||||||||||||
38 | 25 | Revolving Magnetic field, Squirrel cage and phase wound rotor | 1 | CHAPTER NO.10 (AC),PAGE NO.663 | ||||||||||||||||||||||
39 | 26 | Starting of Induction motors,Direct on line and Star Delta starters | 1 | CHAPTER NO.10 (AC),PAGE NO.695-699 | ||||||||||||||||||||||
40 | 27 | Synchronous machines | 1 | CHAPTER NO.11 (AC),PAGE NO.728-730 | ||||||||||||||||||||||
41 | Unit IV Transformers: FROM BASIC ELECTRICAL ENGINEERING BY ABHIJIT CHAKRABARTI (AC) | |||||||||||||||||||||||||
42 | 28 | Construction and principle of operation, equivalent circuit | 1 | CHAPTER NO.8 (AC),PAGE NO.530-546 | ||||||||||||||||||||||
43 | 29 | Construction and principle of operation, equivalent circuit | 1 | CHAPTER NO.8 (AC),PAGE NO.530-546 | ||||||||||||||||||||||
44 | 30 | losses in transformers, regulation and efficiency | 1 | CHAPTER NO.8 (AC),PAGE NO.552-560 | ||||||||||||||||||||||
45 | 31 | losses in transformers, regulation and efficiency | 1 | CHAPTER NO.8 (AC),PAGE NO.552-560 | ||||||||||||||||||||||
46 | 32 | Auto-transformer and three-phase transformer connections | 1 | CHAPTER NO.8 (AC),PAGE NO.568-571 | ||||||||||||||||||||||
47 | ||||||||||||||||||||||||||
48 | 33 | Auto-transformer and three-phase transformer connections | 1 | CHAPTER NO.8 (AC),PAGE NO.568-571 | ||||||||||||||||||||||
49 | 34 | Measuring Instruments:Electromagnetism, Different Torques in Indicating instruments, | 1 | CHAPTER NO.13 (AC),PAGE NO.788-792 | ||||||||||||||||||||||
50 | 35 | Moving Iron Instruments: Construction & Principle, Attraction and Repulsion type; | 1 | CHAPTER NO.13 (AC),PAGE NO.794-803 | ||||||||||||||||||||||
51 | 36 | Moving Coil instruments: Permanent Magnet type; Dynamometer type Instruments | 1 | CHAPTER NO.13 (AC),PAGE NO.803-805 | ||||||||||||||||||||||
52 | Signature of Staff : | |||||||||||||||||||||||||
53 | ||||||||||||||||||||||||||
54 | ||||||||||||||||||||||||||
55 | ||||||||||||||||||||||||||
56 | ||||||||||||||||||||||||||
57 | ||||||||||||||||||||||||||
58 | ||||||||||||||||||||||||||
59 | ||||||||||||||||||||||||||
60 | ||||||||||||||||||||||||||
61 | ||||||||||||||||||||||||||
62 | ||||||||||||||||||||||||||
63 | ||||||||||||||||||||||||||
64 | ||||||||||||||||||||||||||
65 | ||||||||||||||||||||||||||
66 | ||||||||||||||||||||||||||
67 | ||||||||||||||||||||||||||
68 | ||||||||||||||||||||||||||
69 | ||||||||||||||||||||||||||
70 | ||||||||||||||||||||||||||
71 | ||||||||||||||||||||||||||
72 | ||||||||||||||||||||||||||
73 | ||||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | ||||||||||||||||||||||||||
76 | ||||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | ||||||||||||||||||||||||||
79 | ||||||||||||||||||||||||||
80 | ||||||||||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||
100 | ||||||||||||||||||||||||||