ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
2
PROJECT : PAGE :
3
CLIENT :
DESIGN BY :
4
JOB NO. : DATE :
REVIEW BY :
5
Existing Concrete Floor Enhancement Based on 2015 IEBC, ASCE 41-17 & ACI 318-14
6
7
DESIGN CRITERIA
8
1. The existing concrete floor can be either PT-concrete floor or regular one way slab. For PT-concrete floor, assume that only 50% existing
9
concrete floor weight balanced by left post-tensioned force, without secondary moment changes added back to enhanced floor.
10
2. The capacity of existing floor regular reinforcement ignored conservatively. Superimposed load supported by new steel plates that epoxy
11
adhered to existing bottom of floor.
<== Tips:
12
3. Before new shotcrete, to rough, clear and wet the existing surface is required.
1.
The NEW REINFORCEMENT may be replaced by regular rebars, but the COVER has to be 0.75 in minimum.
13
14
INPUT DATA & DESIGN SUMMARY
15
EXISTING FLOOR SECTION THICKNESS
h =8
in, (203 mm).
16
EXISTING FLOOR STRENGTH
old fc' =4,3
ksi, (30 MPa)
17
FLOOR SPAN (larger span for two-way)
L =30
ft, (9.1 m).
18
19
SUPERIMPOSED LOAD (on the top of floor)
w =75
psf, (3.6 kPa), ASD
20
21
NEW SHOTCRETE THICKNESS
T =3
in, (76 mm).
22
NEW STEEL YIELD STRESS
Fy =50
ksi, (345 MPa)
23
NEW SHOTCRETE STRENGTH
fc' =5
ksi, (34 MPa)
THE DESIGN IS ADEQUATE.
24
THE MAX CONCRETE STRESS
b =0,85
fc' (0.85 on ACI, 1.0 on AISC)
25
THE MAX CONCRETE STRAINS
emax =0,003
, (ASCE 41-17 10.3.3.1)
2.
The b, emax, C, fc' & Ec all coupled together, but ACI 318-14, ASCE 41-17, and AISC 341-16 have their different values, which may not be adequate, even on single code self.
26
If purchaser got comments that our results different with other famous/big software, please directly email us the comments and the checker's contact information.
27
NEW BOTTOM REINFORCEMENT
1/8in thk5in wide @12
in. (305 mm), o.c.
We do prompt response to save your time.
28
29
AXIAL EXISTING PT STRESS (zero for not sure)
PT / Area =
0,175
ksi, (1.2 MPa), ASD
30
31
ANALYSIS
32
DETERMINE SECTION FORCES
33
wtotal = 1.6 w + 1.4 Wt =
120+122,5=242,5
psf, (11.6 kPa), SD
34
Mu = (1/8) wtotal L2 =
27,28
ft-kips, (37 kN-m), per foot
35
Vu = (1/2) wtotal L =
3,64
kips, (16 kN), per foot
36
Pu = 1.6 (PT / Area) (h + T) =
36,96
kips, (164 kN), per foot
37
38
CHECK FLEXURAL & AXIAL CAPACITY
39
40
Pn
41
42
43
44
45
46
47
48
Mn .
49
50
51
52
53
54
Pu / f =41,1
kips, (183 kN)
55
Mnc @ Pu / f =
32,8
ft-kips, (45 kN-m)
Solid Line - Tension Controlled
56
>Mu / f =30,3
ft-kips, (41 kN-m)
Dash Line - Compression Controlled
57
[Satisfactory]
58
wheref =0,900
, (ACI 318-14 21.2 & AISC 341-16 B3.2)
59
60
CHECK SHEAR CAPACITY (ACI 318-14 10 & 22.5)
61
Vu / f =4,9kips, (22 kN)<
Vc + Vs =
12,7
kips, (56 kN)
62
wheref =0,75
, (ACI 318-11 21.2)
[Satisfactory]
63
Vc =12,7
kips, (56 kN)
64
Vs =0,0
kips, (0 kN)
65
66
67
68
69
70
LICENSE NUMBER: Package License Including New Software Based on ASCE 41-17, ASCE 7-16, AISC 360/341/358-16
71
72
www.Engineering-International.com
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100