1. Wall Plates
4
3/5.9317.79Wall plates 75 X 125 mm
5
[16.1.1.3
6
Length of buildingBuilding length6000mm
7
6000
8
ddt Overhang 2 TIMES 35 Roof overhang35mm
9
70
10
5930
11
12
13
14
2. Rafter
15
6000
16
Assumed Clearance
17
25Rafter Thickness75mm
18
Half thickness of rafter (smallest side) (0.5 TIMES 75) Rafter spacing400mm
19
38
20
Both sides [2 TIMES (Assumed clearance + Half thickness of rafter)]
21
125
22
Span of rafter
23
5875
24
Rafter spacing (c/c)
25
400
26
Number of rafter
27
16
28
29
30
16/11675 X 125 mm members, 22.5 degree pitch, jointed with
31
27.5 X 2.5 X 1200 mm wall plate straps.
32
[16.2.1
33
34
35
36
37
3. Wall plate straps
38
16/11627.5 X 2.5 X 1200 mm wall plate straps.
39
[16.6.1
40
41
42
43
44
4. Ceiling joist
45
16/11675 X 125 mm ceiling joists.
46
[16.2.1.6
47
48
49
50
51
5. Covering
52
Length of Building
53
60000.5
54
55
Width of Building Building width3000mm
56
3000
57
Soffit board (Longest side) Soffit board225mm
58
225Fascia thickness25mm
59
Half thickness of fascia (smallest side) (0.5 TIMES 25) Roof gutter length113mm
60
13
61
Half span of of roof gutter (0.5 TIMES 113)
62
57
63
3294USE AUTOCAD IF DRAWINGS ARE AVAILABLE.
64
65
Roof pitch
66
22.5Roof pitch22.5degree
67
Roof slope
68
3565
69
70
71
Roof coverings. 22.5 degree pitch, Clay plain tiles covering,
72
45 X 50 mm tile battens, ne 600 c/c
73
[18.1.1
74
75
6.00&
76
3.5721.39
77
78
6. Breathable membrane
79
Web UV 10 standard grade breather membrane
80
[17.1.2
81
82
83
84
7. Insulation
85
86
21.39Rafter thickness75mm
87
DDT area of rafterRafter Length3565mm
88
4.195Area of rafter4194916mm^2
89
17.197
90
91
17.20125 mm Knauf Earthwool, Rocksilk RS45 insulation, glass mineral wool
92
[31.3.3
93
94
95
8. Fascia board
96
Fascia board 25 X 125 mm
97
[
98
6.006.00
99
&
100
9. Vented soffit board.