ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
BUILDING ENERGY CALCULATOR
2
HOW TO USE THE CALCULATOR
3
ParameterUnitsInputDetails of InputNotesGo down the list of parameters 1-10 on the left, and fill in the inputs (column D) according to your buildings specification. Details of the input tells you how to input the values.
4
1Building Gross Floor Aream2User InputAccepted values from >= 5000
5
1aBuilding Size ClassificationLarge
User Select from Dropdown
Select from dropdown only if Parameter 1 is left empty
6
2Window-to-Wall Ratio (WWR)0.5User InputAccepted values from 0 to 1
7
3Wall U-ValueW/m2K0.81User InputDefault value is 1TRUE
8
4Fenestration TypesAluminium Curtain Wall
User Select from Dropdown
9
5Glazing TypesDouble Glazing
User Select from Dropdown
10
6Number of PanelsDouble Panel
User Select from Dropdown
Select...
11
7
Aluminium Curtain Wall Glass U-Value
W/m2K1.5User InputFrame is accounted for separately
12
8Aluminium Curtain Wall Glass SHGC0.25User InputImage 1-
13
9Fenestration Widthm1User Input
Dimensions for each fenestration system (i.e. one slab)
Configurations for window and curtain walls (CW)
14
10Fenestration Heightm2User InputRefer to Image 1 on the right
a in the image is width (W), b is height (H)
15
16
17
RESULTS
18
RESULT PARAMETERUNITSNon TBBasic TBAdvanced TB
Please refer to 'Behind the Scenes Calculation' for more details on how each of these results are generated.
19
Building SizeLarge
20
Window Frame U-ValueW/m2K1553
As discussed, users will not be able to select window frame parameters in the initial prototype.
21
Window Frame SHGC0.2810.0940.056
It will be selected for them. If required, user inputs can be enabled in the future.
22
Overall Window U-ValueW/m2K5.2753.4152.915
23
Overall Window SHGC0.2580.2110.202
24
ETTVW/m245.01636.18034.195Calculated using formula
25
ETTV Percentage Difference%NA19.6324.04
26
Enhanced ETTVW/m253.66642.56439.986Calculated using formulaImage 2-
27
Yearly HVAC Energy Consumption
kWh/yr1,950,3771,813,7541,783,064
Definitions obtained from BCA Building Energy Benchmark Report 2021
28
Energy Use Intensity (EUI)
kWh/m2.yr
188.6179.5177.4NEW: Refer to defintions in image 2 to the right.
29
Energy SavingskWh/yrNA136,624167,313
Energy savings and carbon emission savings are relative to the non thermally-broken scenario.
30
HVAC Energy Savings%NA7.008.58
31
EUI Improvement%NA4.835.92
32
Carbon Emissionkg CO2/yr1,178,9151,121,9701,109,179
33
Carbon Emission Savingskg CO2/yrNA56,94569,736
34
Carbon PaybackyrNA0.06860.0846
Time taken to offset lifecycle carbon emission. Function of the total mass of the thermal break.
35
Estimated ROIyrNA2.10402.4880
Function of the energy savings minus initial costs.
36
Note: the carbon emission & ROI cells in have not been implemented fully. Further discussions needed. Refer to 'Behind the Scenes Calculation'
37
38
39
40
41
42
Further Notes on base case building: GFA = 7500m2
43
This would classify our 12-storey building as medium office.
44
Depending on the parameters used, this will put the energy consumption in the 2nd quartile, as per the screenshot below.
45
Note that we are using HVAC energy consumption which does not account for the appliances.
46
bca-building-energy-benchmarking-report-(bebr)-2021.pdf
BCA Building Energy Benchmark Report 2021
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100