Simulation Platform Inputs & Tiers
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

 
View only
 
 
ABCDEFG
1
TIERS1234CATEGORIES
2
RetrofitsLightPartialSubstantialComprehensiveLighting
3
PurposeBuilding Energy BenchmarkingReduced Order Energy SimulationsDetailed Retrofit EvaluationsDetailed Retrofit Design ProcessAge
4
ToolsInverse ModelingDesign Advisor
Retrofit Manager
Energy AuditingAirflow
Human Behavior
Density
5
Market / UsersFunction
6
Accuracy15%30%50%75%Geometry
7
Complexity1 hr16 hrs24 hrs48 hrsLocation/Weather
8
Inputs # Estimate20502001000+Material
9
Input DescriptionActual weather dataMetered Electricity ConsumptionMonthly Natural Gas BillMechanical
10
Monthly Electricity BillTMY3 Weather FileOccupancy PatternsSchedule
11
Occupancy SchedulesSetpoint
12
Lighting Power DensityUtility
13
Lighting Schedules
14
Plug Load Density
15
Plug Schedules
16
HVAC Setpoints
17
Infiltration Rate
18
Envelope Components
19
Outputs DescriptionCost ComparisonCooling Energy Comparison
20
EnvelopeHeating Energy Comparison
21
Electricity ComparisonLighting Comparison
22
Plug Comparison
23
Cost Savings5%10%15%20%
24
Typesphysics based,
variable based degree day model with time-series mode
25
INPUTS
draft1
11+12 unique inputs
23 total
+85 unique inputs
107 total
26
requested by3+ investigators2 investigators1 investigator
27
1people_densitygeometry_exteriorMajor_retrofit_history
28
2type_buildinglighting_power_densityno_buildings_of_type
29
3floorsequipment_power_densitybuilding_story_height
30
4area_floor_totalfloor_elevationspace_boundary_story
31
5window_wall_ratioorientationbuilding_story_name
32
6city_weather_epwroom_widthSpace_Name
33
7roof_materialroom_depthSpace_Volume
34
8wall_materialroom_heightSpace_Type
35
9window_materialwindow_overhang_dephtSpace_Boundary_Name
36
10occupancy_scheduleilluminanceSpace_Boundary_Area
37
11Electricity_monthlylighting_control_typeSpace_Boundary_Space
38
12Gas_monthlyHVAC_primarySpace_Boundary_Elevation
39
13year_builtSpace_Boundary_Type
40
14HeatingOil_monthlyWall_Name
41
15Steam_monthlyWall_Space_Boundaries
42
16wall_thickness
43
17Cavity_Depth
44
18glazing_area*
45
19window_sill_height
46
20window_height
47
21window_width
48
22number_of_windows
49
23mullion_factor
50
24ext_lightshelf_width
51
25ext_lightshelf_height
52
26int_lightshelf_depth
53
27int_lightshelf_width
54
28int_lightshelf_height
55
29dist_to_ext_obstruct*
56
30height of ext_obstruct
57
31elec_illum
58
32control_zone_depth
59
33refl_ceiling
60
34refl_floor
61
35refl_ground
62
36Roof_Insulation
63
37Roof_Insulation_Location
64
38Roof_Insulation_R-Value
65
39Wall_Insulation_Type
66
40refl_wall
67
41Blind Width
68
42Blind Angle When Closed
69
43Blind Color
70
44Slat Emissivity
71
45Slat Absorptivity
72
46shading_device_type
73
47shading_device_refl
74
48shading_device_trans
75
49overhang_type*
76
50overhang dept
77
51overhang width
78
52overhang_height
79
53overhang_reflectance
80
54overhang_transmittance
81
55ext_lightshelfrefl
82
56int_lightshelf_refl
83
57refl_ext_obstruct
84
58Ventilation System
85
59Demand Control Ventilation: Used or not
86
60Fresh Air Rate
87
61Air Change Rate
88
62Unoccupied Air Change Rate
89
63Thermal Mass
90
64Air Flow Rate per Meter Window Width
91
65Vent Supply
92
66Vent Exhaust
93
67Airside Economizer: Present or not
94
68Airside Energy Recovery: Present or not
95
69HVAC system efficiency
96
70Airflow Analysis Zone Name
97
71Airflow Analysis Zone Spaces
98
72lighting_schedule
99
73Auxiliary Equipment (Schedule)
100
74Blind Schedule (Occupied Hours)
Loading...