Heat Pump Hot Water
2
Prices should be in the ballpark and are a guide - not 100% accurate
3
Spreadsheet by Brian Tehan - free to use but must be attributed.
4
Ver 2.9 updated by Wei Hao Tan April 2021
5
Ver 3.0 Updated and merged by Brian Tehan June 2021
6
Ver 3.1 updated by Wei Hao Tan Aug 2022 (added Enviroheat)
7
Ver 3.21 updated by Wei Hao Tan Sept 2022 (EvoHeat provided information to update their new model, added Last Updated column)
8
Ver 3.3 updated by Brian Tehan January 2023
9
The purpose of this spreadsheet is to compare basic technical specifications and some financial data extrapolated from this.
10
The units below were chosen because they are roughly the same size. Most of the manufacturers have a range of sizes. The units below are suitable for a family of 4 or 5, according to the manufacturers.
11
Member: Renew
12
Volunteer: BZE
13
Heat pump HW evaluation (current system electric storage - resistive)
Calculated values
14
Last updatedBrandSize - litresPrice Online at time of checking (2020)STCs - zone 3 2021Rebate @ $35 per STCBasic replace electric install estimateNet PriceCOP (2)Input Power (Kw)- where statedHeat Output (Kw) - Heat pump onlyEnergy to heat tank size by 45C (kWh equivalent) (5)Time to heat whole tank with the heat pump onlyCalculated savings (KWh/day) (4)daily savings $Annual savingspayback (years)Sound level dBLow Temp limitAdditional Resistive element $RefrigerantGWP (6)
15
Sanden GAUS-250EQTB300585033115570053955.000.874.3515.693.618.002.16788.406.8437.00-10NoR744 (CO2)1
16
Eco Alliance Dynaheat ECO-215e215
Free in Victoria https://www.freehotwaterupgrade.com.au/wp-content/uploads/2021/03/d68c43_58f120170c5148f580f662ef3432effc.pdf
3311557004.230.853.5011.243.217.642.06752.52?????49.00-7yesR744 (CO2)1
33 STCs is puzzling given its ordinary specs
17
Quantum 270-08AC6-290270278031108570023954.530.843.8114.123.717.792.10767.953.1248.00-10No
R290 (propane)
4
18
Reclaim REHP-CO2- 250G250470030105070043505.000.854.2513.083.088.002.16788.405.5237.00-10NoR744 (CO2)1
19
Sep-22Evoheat 270-1270379530105070034454.270.943.6014.123.927.662.07754.704.5648.00-7yesR134A1430
20
iStore270280030105070024503.600.943.4014.124.157.221.95711.753.4446.60-7yes
21
Apricus APHP-R290-260260280030105070024504.130.672.6013.605.237.582.05746.883.28
R290 (propane)
4
22
Aug-22Enviroheat250283829101570025234.000.502.0013.086.547.502.03739.1346.00-7yesR134A1430
23
Hydrotherm 275286829101570025534.000.883.5214.384.097.502.03739.133.4549.00-5noR134A1430
24
Thermann Hybrid 220300353029101570032153.580.632.2615.696.967.211.95710.224.5356.00-5yesR134A1430
25
Stiebel Eltron WWK30230036992898070034193.580.551.9715.697.977.211.95710.224.8156.00-5yes (H model)R134A1430
26
Chromagen28023952794570021503.50?1.5014.649.767.141.93703.933.0548.00-7yesR134A1430
27
Bosch27035992794570033543.300.601.5014.129.416.971.88686.864.8840.00-7yesR134A1430
28
Dux25037982691070035883.001.203.6013.083.636.671.80657.005.46
29
ThermalArk27020002691070017902.431.403.4014.124.155.881.59579.713.0948.00-7
30
Rheem HDi-31031046482691070044382.771.303.6016.214.506.391.73629.637.051430
31
32
33
The basic data was taken from the manufacturers specifications and then the other data was calculated using the figures quoted below and the specific heat of water, etc.
34
Any issues or inaccuracies - please contact the author
35
*Thermann and Stiebel-Eltron are basically the same unit, however, their heat pump and booster specs are slightly different
36
Eco Alliance Dynaheat gains a lot of STCs despite its fairly ordinary efficiency specs compared to other vendors offerings – but correct according to the official spreadsheet.
37
Variables (may be changed)
38
Current HWS electricity use10.00kWh
this may be changed - spreadsheet recalculates
39
Electricity Price per KWh0.27Dollars
this may be changed - spreadsheet recalculates
40
41
42
Comments
43
44
Note that the following are outside the scope of this document - tank material, reliability, service and support.
45
Quantum COP is more dependent on outside temp than Sanden at very low temperatures
46
(1) For replacement of electric system - source clean energy regulator
47
(2) COP = efficiency multiplier, higher is better
48
Heat output depends on input and COP - affects the time to heat the tank - some are calculated
49
(3) calculated using heat pump only from 15c to 60c - assume those highlighted in red must use the element to heat up in a reasonable time
50
(4) based on the original usage (cell C21) only
51
(5) Information only - actual energy input required to heat quoted tank size (Column B) - not the amount of electricity used
52
(6) GWP is compared with CO2 as a greenhouse gas - lower is better - 1430 means that 1 Kg = 1.43 tonnes of CO2
53
(7) Reclaim - stainless steel. The model with a glass lined tank is about $1000 cheaper
54
$ resistive element most likely will increase running costs above that of a pure heat pump
55
The resistive element would need to be used when the temperature is low or in the models that take a long time to heat the tank – WON’T GET MUCH SAVINGS
56
TIME TO HEAT A TANK – THE MODELS IN THE GREEN RANGE DO NOT NEED USE A BOOSTER. Time to heat is also dependent on tank size obviously.
57
The COP is usually measured at around 20c, lower temperatures will give lower COP
58
Important technical factors: cost, efficiency, time to heat tank, noise levels
59
60
specific heat of water is 4.186 Joule/gram/degree = 4186 Joule per litre/degree
tap temptank tempDifferenceMJ
kWh required to heat the whole tank
61
volume
Heat Pump COP - shows kWh electricity required at the COP to heat the tank
62
44.55
63
15.0065.0050.0054.41815.116111113.783.363.02
64
26020654548.976213.60453.403.022.72
65
26015655062.7917.441666674.363.883.49
66
30020654556.51115.69753.923.493.14
67
300
68
69
The heat pump COP in the first table is usually measured at 20C. The COP varies as the temperature. EG, the Quantum is 4 @ 15C , 4.5 @20C and 5 @ 25C
70
The calculations are examples - a number of factors affect the actual energy used, including standing losses, ambient temperature, water temperature and humidity (increases the COP)