| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | AA | AB | AC | AD | AE | AF | AG | AH | AI | AJ | AK | AL | AM | AN | AO | AP | AQ | AR | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Handheld Digitial Multi-Meter Transient Test Results | |||||||||||||||||||||||||||||||||||||||||||
2 | ||||||||||||||||||||||||||||||||||||||||||||
3 | Round I Tests using first generation transient generator | |||||||||||||||||||||||||||||||||||||||||||
4 | Manufactuer | Model | Cost | Rating | Res | RMS | Tmp | nS | mV | uA | NCV | AC+DC | Max DC (1KV / 600V) | Rectified 220V Line | Piezo Grill Ignitor | ESD Gun, 4KV | 2.0KV, 49 ohm | 2.0KV, 14 ohm | 2.0KV, 2 ohm | 2.8KV, 2 ohm, 30 | 3.2KV, 2 ohm | 3.7KV, 2 ohm | 5.0KV, 2 ohm, 40 | 5.8KV, 2 ohm, | 6.5KV, 2 ohm, 50us FWHH | 12KV, 2 ohm, 50us FWHH | 13KV, 2ohm, 100us FWHH | |||||||||||||||||
5 | Amprobe | AM510 | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||
6 | BK | 2703C | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
7 | Cen-Tech/Mastech | P98674/MS8229 | NT | NT | Fail | |||||||||||||||||||||||||||||||||||||||
8 | Extech | MN16A | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
9 | Fluke | 101 | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | ||||||||||||||||||||||||||||||
10 | Klien Tools | MM500 | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||||
11 | Mastech | MS8264 | Fail | |||||||||||||||||||||||||||||||||||||||||
12 | UNI-T | UT90A | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||||
13 | UNI-T | 139C | NT | NT | NT | NT | NT | Fail | ||||||||||||||||||||||||||||||||||||
14 | Gardner Bender | GDT-311 | Fail | |||||||||||||||||||||||||||||||||||||||||
15 | Sears | DM-301 | Pass | Fail | ||||||||||||||||||||||||||||||||||||||||
16 | Cen-Tech | 98025 | Fail | |||||||||||||||||||||||||||||||||||||||||
17 | Fluke | 87V | NT | NT | NT | NT | NT | NT | NT | NT | NT | NT | Fail | |||||||||||||||||||||||||||||||
18 | Cen-Tech | P37772 | Pass | Pass | ||||||||||||||||||||||||||||||||||||||||
19 | ||||||||||||||||||||||||||||||||||||||||||||
20 | Round II Tests using second generation higher energy transient generator | Original Generator Final Design | ||||||||||||||||||||||||||||||||||||||||||
21 | Manufactuer | Model | Cost | Rating | Res | RMS | Tmp | nS | mV | uA | NCV | AC+DC | Max DC (1KV / 600V) | Rectified 220V Line | Piezo Grill Ignitor | ESD Gun, 4KV | 1.0KV, 2 ohm, 100us FWHH | 1.5KV, 2 ohm | 2.0KV, 2 ohm | 2.5KV, 2 ohm | 3.0KV, 2 ohm | 4.0KV, 2 ohm | 5.0KV, 2 ohm | 5.9KV, 2 ohm | 6KV, 2 ohm, 50us FWHH | 8KV, 2 ohm, 50us FWHH | 10KV, 2 ohm, 50us FWHH | 12KV, 2 ohm, 50us FWHH | 14KV, 2 ohm, 50us FWHH | 15KV, 2 ohm, 50us FWHH | 13KV, 2ohm, 100us FWHH | 14KV, 2ohm, 100us FWHH | 15KV, 2ohm, 100us FWHH | |||||||||||
22 | UNI-T | UT90A(repaired) | $30 | C3/600 | 2k | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||
23 | Klein | MM2000 | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||
24 | UNI-T | UT61D | Fail | |||||||||||||||||||||||||||||||||||||||||
25 | Amprobe | AM530 | $80 | C3/600 | 4k | X | 1 | X | X | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||
26 | RadioShack | 2200087 | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | NT | NT | NT | NT | Fail | ||||||||||||||||||||||||||
27 | UNI-T | UT61E | Fail | |||||||||||||||||||||||||||||||||||||||||
28 | Fluke | 107 | $110 | C3/600 | 6k | AC | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | NT | NT | NT | NT | Pass | Pass | Fail | |||||||||||||||||||
29 | TekPower | TP40 | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||||||
30 | TekPower | TP2844R | Pass | Fail | Pass | |||||||||||||||||||||||||||||||||||||||
31 | BK | 2705B | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
32 | CircuitTest | DMR-6550 | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
33 | UTL | UTLDM 2 | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
34 | SouthWire | 12070T | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
35 | HoldPeak | HP-760H | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||
36 | Innova | 3320 | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||||
37 | Extech | EX430 | Fail | |||||||||||||||||||||||||||||||||||||||||
38 | Brymen | BM869S | $230 | C4/1K | 50k | X | 2 | X | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | NT | NT | NT | NT | NT | Fail | |||||||||||||||
39 | Brymen (2nd Unit) | BM869S | NT | NT | NT | NT | NT | NT | NT | NT | NT | NT | NT | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||
40 | Fluke (105xxxxx) | 87V | 6k | X | 1 | X | X | X | NT | NT | NT | NT | Pass | Fail | ||||||||||||||||||||||||||||||
41 | Fluke (105xxxxx) | 87V (repaired) | 6k | X | 1 | X | X | X | Pass | Pass | NT | NT | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Replace all diodes used for low voltage clamp, BAV199, SOD123 5237 | |||||||||||||||||||||||
42 | Fluke (409xxxxx) | 87V | 6k | X | 1 | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||
43 | Fluke | 17B+ | $156 | C3/600 | 4k | 1 | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||
44 | Fluke | 101 | $48 | C3/600 | 6k | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | |||||||||||||||||||||||
45 | UNI-T | UT139C | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||
46 | Amprobe | AM510 | $50 | 4k | X | Pass | NT | NT | NT | NT | NT | NT | Pass | |||||||||||||||||||||||||||||||
47 | Fluke | 115 | $132 | C3/600 | 6k | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | |||||||||||||||||||||
48 | Greenlee | DM-20 | $30 | 2k | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||
49 | UNI-T | UT15C | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||
50 | Keysight | U1231A | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||
51 | Vici | VC99 | Pass | Fail | ||||||||||||||||||||||||||||||||||||||||
52 | Hioki | DT4252 | $150 | C4/600 | 6k | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass* | Pass* | Pass* | * Added plastic insulator around insert near fuse to prevent breakdown | |||||||||||||||||||
53 | UNI-T | UT181A | $300 | C4/600 | 60k | X | 2 | X | X | X | X | Pass | Pass | Fail | ||||||||||||||||||||||||||||||
54 | UNI-T Modified* | UT181A | Pass | Pass | Pass | Pass | Pass | NT | Pass | NT | NT | Pass | NT | Pass | NT | Pass | NT | NT | NT | Pass | * Meter was modified to handle higher transients (including ESD) without damage | |||||||||||||||||||||||
55 | UNI-T | UT10A | C2/300 | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||
56 | UNI-T | UT20B | C2/300 | Pass | Fail | Pass | ||||||||||||||||||||||||||||||||||||||
57 | VICTOR | VC921 | C2/300 | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||||
58 | TPI/SUMMIT | TIP 194 II | $250 | C4/600 | 50k | X | 1 | X | X | X | X | Pass | Fail | |||||||||||||||||||||||||||||||
59 | UNI-T Modified* | UT61E | C4/600 | 20k | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | NT | Pass | Pass | Pass | Pass | * Meter was modified to handle higher transients (including ESD) without damage | ||||||||||||||||||||||||
60 | Brymen | BM235 (EEVBLOG) | $130 | C4/300, C3/600 | 6k | X | 1 | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | |||||||||||||||||||
61 | Mastech | MS8211D | $20 | C3/600 | 2k | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||||||||||
62 | Mastech | MS8211 | $20 | C3/600 | 2k | Pass | Fail | Pass | ||||||||||||||||||||||||||||||||||||
63 | CEM | DT-9939 | $120 | C4/600 | 40k | X | 1 | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | ||||||||||||||||||||||||||
64 | Woods | DMMW3 | $30 | C3/300 | 4k | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||||||||
65 | KASUNTEST | ZT102 / AN8002 | $20 | C3/600 | 6k | X | 1 | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||
66 | KASUNTEST | KT6000 | $37 | C4/600 | 6k | X | 1 | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||
67 | Gossen Metrawatt | M248B | $850 | C4/300 | 300k | X | 1 | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | ||||||||||||||||||
68 | ANENG | AN8008 | $23 | C3/600 | 10k | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||||
69 | Brymen | BM319s | $130 | C3/600, C4/300 | 6k | 1 | X | X | Pass | Pass | NT | Pass | NT | NT | Pass | NT | NT | Pass | NT | Pass | ||||||||||||||||||||||||
70 | Brymen | BM839 | C3/1000, C4/600 | 6/20k | X | 1 | X | X | X | Pass | Pass | NT | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||
71 | METERK | MK01A | $9 | C4/600 | 6k | X | 1 | X | X | X | Pass | Pass | Fail | |||||||||||||||||||||||||||||||
72 | Brymen/AMPROBE | BM27s/PM55A | $55 | C2/600, C3/300 | 6k | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | Meter was not electrically damaged. More testing is needed. | ||||||||||||||||||||||
73 | OWON | B41T | $70 | C3/1000 | 20k | X | 1 | X | X | Pass | Fail | Pass | Pass | Meter was repaired in order to run EDS testing. | ||||||||||||||||||||||||||||||
74 | Yokagowa | TY720 | $500 | C3/1000, C4/600 | 50k | X | 1 | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||
75 | UEI/EEVBlog | 121GW | $213 | C3/600 | 50k | X | 1 | X | X | X | Pass | Pass | Fail | * | * | * | * | High leakage after grill starter causing errors in reading, continued testing meter to full failure | ||||||||||||||||||||||||||
76 | Brymen | BM786 | ND | C3/1000, C4/600 | 60k | X | 1 | X | X | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | NT | Fail | ||||||||||||||||
77 | Brymen | BM789 | ND | C3/1000, C4/600 | 60k | X | 2 | X | X | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | ||||||||||||||||||||
78 | UNI-T | UT61E+ | $100 | C3/1000, C4/600 | 20k | X | X | X | X | Damaged during initial checkout of frequency counter feature. Unable to test. | ||||||||||||||||||||||||||||||||||
79 | Keysight | U1282A | $760 | C3/1000, C4/600 | 60k | X | 1 | X | X | X | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||
80 | Manufactuer | Model | Cost | Rating | Res | RMS | Tmp | nS | mV | uA | NCV | AC+DC | Max DC (1KV / 600V) | Rectified 220V Line | Piezo Grill Ignitor | ESD Gun, 4KV | 1.0KV, 2 ohm, 100us FWHH | 1.5KV, 2 ohm | 2.0KV, 2 ohm | 2.5KV, 2 ohm | 3.0KV, 2 ohm | 4.0KV, 2 ohm | 5.0KV, 2 ohm | 5.9KV, 2 ohm | 6KV, 2 ohm, 50us FWHH | 8KV, 2 ohm, 50us FWHH | 10KV, 2 ohm, 50us FWHH | 12KV, 2 ohm, 50us FWHH | 14KV, 2 ohm, 50us FWHH | 15KV, 2 ohm, 50us FWHH | 13KV, 2ohm, 100us FWHH | 14KV, 2ohm, 100us FWHH | 15KV, 2ohm, 100us FWHH | |||||||||||
81 | UNI-T | UT125C | $27 | C3/600 | 4k | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | Damaged high speed clamp transistors. Was able to repair. | ||||||||||||||||||||||||||
82 | UNI-T | UT33A+ | $50 | C2/600 | 2k | X | X | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Pass | Fail | |||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||||||||||||||||||||
100 |