pump speeds.ods
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

 
View only
 
 
ABCDEFGHIJKLMNO
1
Gbox Ratio 7.5Primary Belt Ratio4Secondary Belt Ratio3
2
Crank RPMG/B InputPump SpeedAlternator
Alternator Current (A)
Malcolm's Planned Design
3
502002760010390
Water needed lbs/hr
4
602403272010176.9
Water needed Kg/hr
5
722883886420450Engine rpm
6
86344461032301.88:1
Pump Gearbox Ratio
7
10341255123630232
Pump strokes per minute
8
1234926614763013,920strokes/hr
9
147588781764340.013 kg
Required water/stroke (Kg or Litres)
10
176704942112506.4 cc
Required capacity per stroke (given 2 pumps)
11
2118441132532622.205 in5.600 cmPump stroke
12
25310121353036681.13 cm2
required area (piR2)
13
30312121623636680.3612r squared
14
36314521944356740.6010radius
15
43517402325220771.202 cmdiameter
16
522208827862647912.020 mm
required bore (mm)
17
.473 in
required bore (inches)
43.97 lbf
load on crank (per pump)
18
0.6350.5
actual pump bore
98.17 lbf
load on crank (2 pumps)
19
A127 Alternator performance
197.49431
actual capacity (l/hr)
89.06torque lb-inFor 2 pumps
20
RPMCurrent111.64%
of required capacity
7.42Torque-lb-ft
21
0026.5
22
5000
23
60010
24
75020As designed
25
100030.953 cm.375 inpump bore
26
160034187
capacity in KG/hr
27
180043105.88%
of capacity required
28
2000504.868 cm
Pump stroke (3” engine stroke * operating lever ratio)
29
250062
30
300068
31
400074
32
500077
33
600079
34
12000max safe
Loading...