4
Applications Multi-Range Full Scale Pressure LimitsNumber of Pressure RangesOutput CharacteristicsPerformanceSystem Features
5
Update RateBW Corner FrequencyDigital vs AnalogAccuracy % RangeLong-Term StabilityShort Term Error BandTotal Error BandPositional InsensitivityZ-Track™ Zero Tracking50/60 Hertz Notch FilterDatasheetsBuy Now
6
Min FSSMax FSS
7
8
CPAP, BiPAP, APAPCP201 - Diff250 Pa2500 Pa42 ms25 - 250 HzDigital0.05%< 2 Pa< 1.25 Pa< 4 PaNo NoNoDownload DatasheetDigiKey Buy Now
9
CP201 - Gage
2k Pa6k Pa< 12 Pa< 6 Pa
12
13
Spirometry, PFT, FOTSP1605k Pa40k Pa42 ms25 - 250 HzDigital0.10%< 20 Pa< 10 Pa< 25 PaNo YesNoDownload DatasheetDigiKey Buy Now
14
SP110250 Pa2500 Pa4< 2 Pa< 1.25 Pa< 4 PaNo Mouser Buy Now
15
SP210250 Pa2500 Pa4< 1.25 Pa< 0.75 Pa< 1.75 PaYes
16
19
Air Handling, HVAC, Room PressurizationHV160625 Pa15k Pa89 ms0.1 - 10 HzDigital0.10%< 8 Pa< 5 Pa< 15 PaNoNoYesDownload DatasheetDigiKey Buy Now
20
HV120625 Pa5k Pa4< 5 Pa< 3 Pa< 5 PaNo
21
HV110125 Pa2500 Pa5< 2 Pa< 1.25 Pa< 4 PaNoMouser Buy Now
22
HV21025 Pa2500 Pa7< 1.25 Pa< 0.75 Pa< 1.75 PaYes
23
27
Differential Pressure Transmitter (DPT)HS160625 Pa15k Pa329 ms0.1 - 10 HzAnalog0.15%< 8 Pa< 5 Pa< 15 PaNoNoYesDownload DatasheetPlease Contact Us
28
HS120625 Pa5k Pa32< 5 Pa< 3 Pa< 5 PaNo
29
HS110125 Pa2500 Pa32< 2 Pa< 1.25 Pa< 4 PaNo
30
HS21025 Pa2500 Pa32< 1.25 Pa< 0.75 Pa< 1.75 PaYes
31
35
IndustrialND130500 Pa7.5k Pa72.25 ms1 - 200 HzDigital0.05%< 25.0 Pa< 15.0 Pa< 25.0 PaNoNoYesDownload DatasheetDigiKey Buy Now
36
ND120250 Pa5k Pa7< 15.0 Pa< 10.0 Pa< 15.0 PaNo
37
ND110125 Pa2500 Pa6< 7.5 Pa< 5.0 Pa< 7.5 PaNoMouser Buy Now
38
ND21062.5 Pa2500 Pa7< 5.0 Pa< 3.5 Pa< 5.0 PaYes
39
ND005D0.5 PSI5 PSI6< 100.0 Pa< 35.0 Pa< 50.0 Pan/a
40
41
Medical, Air Quality, Flow Meter, VentilatorCustom25 Pa15 PSICustom1 ms0.1 - 500 HzAnalog or Digital0.10%< 1.25 Pa< 0.75 Pa< 1.25 PaYesYesYesPlease Contact Us
42
43
Common Device Features: 3.3V supply, 16 bits resolution (all selected ranges)
44
Long-Term Stability is measured after first 12 months
45
Short-Term Error Band (STEB) is measured over 24 hours, after auto-zero
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110