ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Design of Footing at Piping Based on ACI 318-14
2
3
INPUT DATA & DESIGN SUMMARY
4
COLUMN WIDTH
c1=5in
5
COLUMN DEPTH
c2=5in
6
BASE PLATE WIDTH
b1=16in
7
BASE PLATE DEPTH
b2=16in
8
FOOTING CONCRETE STRENGTH
fc'=2,5ksi
9
REBAR YIELD STRESS
fy=60ksi
10
AXIAL DEAD LOAD
PDL=40k
11
AXIAL LIVE LOAD
PLL=25k
12
LATERAL LOAD (0=WIND, 1=SEISMIC)
=0Wind,SD<== Tips:
The ASCE 7-10 wind loads have been changed to SD level.
13
WIND AXIAL LOAD
PLAT=20k, SD
If ASCE 7-05, or early, the input wind loads should be increased by 1.6.
14
WIND MOMENT LOAD
MLAT=96ft-k, SD
15
WIND SHEAR LOAD
VLAT=2k, SD
16
SURCHARGE
qs=0,1ksf
17
SOIL WEIGHT
ws=0,11kcf
18
FOOTING EMBEDMENT DEPTH
Df=3ft
19
FOOTING MIDDLE THICKNESS
T=18in
20
SOIL COVER THICKNESS
D=12in
21
ALLOW SOIL PRESSURE
Qa=3ksf
22
SQUARE FOOTING LENGTH
L=7ft
23
REINFORCING SIZE
#5
24
25
26
MIDDLE BOTTOM EACH WAY :
9 # 5 @ 9 in o.c.
THE DESIGN IS INADEQUATE, SEE BELOW.
27
28
29
ANALYSIS
30
DESIGN LOADS (IBC SEC.1605.3.2 & ACI 318 5.3)
31
CASE 1:DL + LLP=65kips
32
M=0ft-kips
33
CASE 2:DL + LL + 0.6(1.3) WP=81kips
34
M=75ft-kips
35
CASE 3:DL + LL + 0.6(0.65) WP=73kips
36
M=37ft-kips
37
38
CHECK OVERTURNING FACTOR (IBC 1605.2.1, 1808.3.1, & ASCE 7 12.13.4)
39
MR / MO =
6,4>
F = 1.0 / 0.9
[Satisfactory]
40
WhereMO =
MLAT + VLAT Df - 0.5 PLAT L =
32k-ft
41
Pconc =
(0.15 kcf) L2 [T + 2 (Df - D - T) /3] =
13,48
k, footing wt
42
Psoil =
ws D L2 =
5,39
k, soil weight
43
MR =
0.5 PDLL + 0.5 (Pconc + Psoil) L =
206k-ft
44
45
46
CHECK SOIL BEARING CAPACITY (ACI 318 13.3.1.1)
47
48
Service Loads
CASE 1CASE 2CASE 3
49
P65,080,672,8k
50
qs L24,94,92,9
k, (surcharge load)
51
P conc - soil
3,63,62,2
k, (footing increased)
52
S P73,589,177,9k
53
S M0,074,937,4ft - k
54
qmin2,250> 01,367> 01,704> 0
ksf, net pressure
55
q32,2502,2742,158
ksf, net pressure
56
q22,2503,1812,611
ksf, net pressure
57
qmax2,2504,0883,065
ksf, net pressure
58
qallow3,04,04,0ksf
59
60
(cont'd)
61
Where
62
63
[Unsatisfactory]
64
65
66
67
68
DESIGN FLEXURE & CHECK FLEXURE SHEAR (ACI 318 13.2.7, 21, & 22)
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
Service Loads
CASE 1CASE 2CASE 3
84
V36,759,446,4
k, flexure shear
85
M69,7115,489,3
ft - k, flexure moment
86
87
88
89
90
91
DESIGN FLEXURE
92
Location
Mu,max = 1.5 M
d (in)rminrreqDrmaxsmaxuserprovD
93
Middle Bottom Each Way
173,1ft-k14,690,00220,00220,012918
9 # 5 @ 9 in o.c.
0,0023
94
[Satisfactory]
95
CHECK FLEXURE SHEAR
96
Direction
Vu,max = 1.5 V
fVc = 2 f b d (fc')0.5
check Vu < f Vc
97
Pipe Direction
89,0k93k
[Satisfactory]
98
99
CHECK PUNCHING SHEAR (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)
100