ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Note:
When the sweeper does not work, it is in hibernation state. In hibernation state, it should wake up first and then send effective instruction (send wake up instruction 0x00, and then send effective instruction 50ms later).
To be effective, the serial port commands to start and stop decoding must be in the host mode. Please switch to the host mode first (see serial port instruction table for details).
2
categoryfunctionparameterSetting and Operation instructions (hexadecimal)ACK
3
General command1.Setting default ParametersRestore factory default Settings08 C6 04 08 00 F2 FF 00 FD 3504 D0 00 00 FF 2C
4
2.Querying the Software VersionReturn the current version information04 A3 04 00 FF 55Return version information
5
3.Decode start and stop SettingsStart Scan04 E4 04 00 FF 141.Non-host mode:05 D1 00 00 06 FF 24
2.Host mode:04 D0 00 00 FF 2C Decoded successfully returns decoded data
6
Stop Scan04 E5 04 00 FF 13
7
model4.Trigger modeThe host07 C6 04 08 00 8A 08 FE 9504 D0 00 00 FF 2C
8
Level (key hold)07 C6 04 08 00 8A 00 FE 9D
9
Pulse (single trigger)07 C6 04 08 00 8A 02 FE 9B
10
Continuous mode07 C6 04 08 00 8A 04 FE 99
11
Automatic induction mode07 C6 04 08 00 8A 09 FE 94
12
communication5.Communication modeRS232 TTL08 C6 04 08 00 F2 01 00 FE 33
13
USB KBW (USB keyboard port)08 C6 04 08 00 F2 01 01 FE 32
14
USB COM08 C6 04 08 00 F2 01 02 FE 31
15
6.Baud rate480007 C6 04 08 00 9C 05 FE 86
16
960007 C6 04 08 00 9C 06 FE 85
17
1920007 C6 04 08 00 9C 07 FE 84
18
3840007 C6 04 08 00 9C 08 FE 83
19
5760007 C6 04 08 00 9C 09 FE 82
20
11520007 C6 04 08 00 9C 0A FE 81
21
output format7.End settingforbid08 C6 04 08 00 F2 05 00 FE 2F
22
CR LF 08 C6 04 08 00 F2 05 01 FE 2E
23
CR 08 C6 04 08 00 F2 05 02 FE 2D
24
TAB 08 C6 04 08 00 F2 05 03 FE 2C
25
CR CR 08 C6 04 08 00 F2 05 04 FE 2B
26
CR LF CR LF 08 C6 04 08 00 F2 05 05 FE 2A
27
Light setting8.Lighting controlLight on reading (default)08 C6 04 08 00 F2 02 00 FE 32
28
Lighting Form08 C6 04 08 00 F2 02 01 FE 31
29
not allow08 C6 04 08 00 F2 02 02 FE 30
30
9.Position light controlLight on reading (default)08 C6 04 08 00 F2 03 00 FE 31
31
Lighting Form08 C6 04 08 00 F2 03 01 FE 30
32
not allow08 C6 04 08 00 F2 03 02 FE 2F
33
10.Decoder success indicatorOn (default)08 C6 04 08 00 F2 0B 01 FE 28
34
Shut down08 C6 04 08 00 F2 0B 00 FE 29
35
Sound Settings11.Mute/Enable or disable All announcementsDisable (default)08 C6 04 08 00 F2 0C 00 FE 28
36
enabled08 C6 04 08 00 F2 0C 01 FE 27
37
12. Buzzer volumeHigh (default)07 C6 04 08 00 8C 00 FE 9B
38
middle07 C6 04 08 00 8C 01 FE 9A
39
low07 C6 04 08 00 8C 02 FE 99
40
13. Boot prompt toneEnable (Default)08 C6 04 08 00 F2 0D 01 FE 26
41
forbid08 C6 04 08 00 F2 0D 00 FE 27
42
14.Set the prompt tone for code parametersEnable (Default)08 C6 04 08 00 F2 0E 01 FE 25
43
forbid08 C6 04 08 00 F2 0E 00 FE 26
44
15.Decoder successful soundEnable (Default)07 C6 04 08 00 38 01 FE EE
45
forbid07 C6 04 08 00 38 00 FE EF
46
Set the time16.
Scanning duration(n*100ms)
default:3000ms
scope:500-25500ms
507 C6 04 08 00 88 05 FE 9A
47
1007 C6 04 08 00 88 0A FE 95
48
3007 C6 04 08 00 88 1E FE 81
49
5007 C6 04 08 00 88 32 FE 6D
50
10007 C6 04 08 00 88 64 FE 3B
51
15007 C6 04 08 00 88 96 FE 09
52
20007 C6 04 08 00 88 C8 FD D7
53
无限07 C6 04 08 00 88 00 FE 9F
54
17.
Stable induction time(n*100ms)
default:500ms
scope:0-9900ms
008 C6 04 08 00 F3 02 00 FE 31
55
108 C6 04 08 00 F3 02 01 FE 30
56
308 C6 04 08 00 F3 02 03 FE 2E
57
508 C6 04 08 00 F3 02 05 FE 2C
58
1008 C6 04 08 00 F3 02 0A FE 27
59
18.
Time between reading
(n*100ms)
default:500ms
scope:0-9900ms
007 C6 04 08 00 89 00 FE 9E
60
107 C6 04 08 00 89 01 FE 9D
61
307 C6 04 08 00 89 03 FE 9B
62
507 C6 04 08 00 89 05 FE 99
63
1007 C6 04 08 00 89 0A FE 94
64
1507 C6 04 08 00 89 0F FE 8F
65
2007 C6 04 08 00 89 14 FE 8A
66
19.
Same code output interval
(n*100ms)
default:500ms
scope:0-9900ms
008 C6 04 08 00 F3 03 00 FE 30
67
108 C6 04 08 00 F3 03 01 FE 2F
68
308 C6 04 08 00 F3 03 03 FE 2D
69
508 C6 04 08 00 F3 03 05 FE 2B
70
1008 C6 04 08 00 F3 03 0A FE 26
71
1508 C6 04 08 00 F3 03 0F FE 21
72
2008 C6 04 08 00 F3 03 14 FE 1C
73
Heart rate control20.Heart rate controlforbid08 C6 04 08 00 F2 CD 00 FD 67
74
The heartbeat does not require an ACK08 C6 04 08 00 F2 CD 01 FD 66
75
Heartbeat needs ACK08 C6 04 08 00 F2 CD 02 FD 65
76
Set the permissions21.
Allows configuration code scanning
Enable (Default)07 C6 04 08 00 EC 01 FE 3A
77
forbid07 C6 04 08 00 EC 00 FE 3B
78
Scan security levellevel 107 C6 04 08 00 4E 01 FE D8
79
level 207 C6 04 08 00 4E 02 FE D7
80
level 307 C6 04 08 00 4E 03 FE D6
81
level 407 C6 04 08 00 4E 04 FE D5
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100