ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Plumbing Systems Summary — 261104 Sample Multi-Story Apartment
2
Bathroom and kitchen piping, Levels L1–L3, with risers (Garage −2'-0" to L4 roof 36'-0") and Garage trunks at 10'-0" above Garage floor.
3
4
SystemPipe Type / MaterialRisersRiser Length (ft)Branch Length (ft)Trunk Length (ft)Total Length (ft)BranchesElbowsTeesReducersTotal FittingsSizes Used
5
Domestic Cold WaterCopper - Type L276.080.122.5178.612451212691/2", 1", 1-1/2"
6
Domestic Hot WaterCopper - Type L276.098.622.1196.712461212701/2", 1-1/4"
7
SanitaryPVC - DWV276.090.227.5193.715421812721", 1-1/4", 1-1/2", 3"
8
VentPVC - Vent276.0127.124.4227.515542712931", 1-1/4", 1-1/2", 3"
9
TOTAL8304.0396.096.5796.5541876948304
10
Lengths are design centerline lengths (fixture connector → riser centerline), computed from the coordinates on 'Pipe Segments'. Modeled pipe lengths are slightly shorter where fittings occupy the run.
11
Fitting counts match the Revit model total of 304 pipe fittings (reducers = transitions Revit added automatically at reducing tees on the risers).
12
13
Fixtures Connected
14
FixtureAreaQty (L1–L3)CWHWSanitaryVent
15
Water Closet (wall-hung, flush valve)Bathroom31"—3"3"
16
Shower Stall 63"x36"Bathroom31/2"1/2"1-1/2"1-1/2"
17
Lavatory - Vanity 36"x18"Bathroom31/2"1/2"1-1/4"1-1/4"
18
Kitchen Sink 18"x18"Kitchen31/2"1/2"1-1/2"1-1/2"
19
Dishwasher 24"Kitchen3—1/2"1"1"
20
Total fixtures15
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100