ABCDEFG
5
Test Setup
6
Date7/19/2021
7
Method8 x 4.5" pyrex containers
8
Time6:30 PM
9
Minutes20
10
11
Measurements
12
Record your data in the cells highlighted belowCalculation Output
13
cupvol_mLdiameter_inarea_in2precip_inprecip_rate_in_per_hr
14
1604.515.900.230.69
15
21084.515.900.411.24
16
3624.515.900.240.71
17
4964.515.900.371.10
18
5624.515.900.240.71
19
6544.515.900.210.62
20
7784.515.900.300.90
21
8344.515.900.130.39
22
23
24
25
Results
26
precip rateuniformity
27
avg_in_per_hr0.80avg_low_quarter_mL44
28
avg_total_mL69.25
29
uniformity0.64
30
31
Assess your uniformity
32
ExcellentVery GoodGoodFairPoor
33
Fixed spray0.750.650.550.50.4
34
Rotor head0.80.70.650.60.5
35
source: NM State University Extension
36
Next Steps
37
Congratulations! You have completed following our catch cup article. You now have accurate prepitation rate and uniformity measurements. Assess your uniformity according to the table above. If yours is Fair or below, consider addressing sprinkler coverage issues to acheive better watering. You can enter your precip rate into your Rachio app Advance Zone Settings.
38