NexBlue_Edge_OCPP_Configs&Features
2
Brand:NexBlue
3
4
README:
5
IntroductionNexBlue-CP-OCPP Charging point(EVSE) and central system OCPP protocol, configuration features supported by charging point.
6
Our charger is compliant with OCPP 1.6 Security Profiles 1 and 2.
7
8
9
Background ColorWhiteSupported
10
BlueDeviation from the standard protocolAuthorizeRemoteTxRequests
11
GreenNot yet, to be supported
12
OrangeNot supported
13
14
15
Configuration
16
ItemSectorOCPP clauseCore Profile fieldRequired / optionalAccessibilityTypeUnitDescriptionDefault Setting ValueRemark
17
1Core Profile9.1.1AllowOfflineTxForUnknownIdoptionalRWbooleanIf this key exists, the Charge Point supports Unknown Offline Authorization. If this key reports a value of true, Unknown Offline Authorization is enabled.FALSERW
18
2Core Profile9.1.2AuthorizationCacheEnabledoptionalRWbooleanIf this key exists, the Charge Point supports an Authorization Cache. If this key reports a value of true, the Authorization Cache is enabled.RW, to be supported
19
3Core Profile9.1.3AuthorizeRemoteTxRequestsrequiredR booleanWhether a remote request to start a transaction in the form of a RemoteStartTransaction.req message should be authorized beforehand like a local action to start a transaction.TRUECurretly R, RW to be supported
20
4Core Profile9.1.4BlinkRepeatoptionalRWintegertimesNumber of times to blink Charge Point lighting when signallingNot supported
21
5Core Profile9.1.5ClockAlignedDataIntervalrequiredRWintegersecondsSize (in seconds) of the clock-aligned data interval. This is the size (in seconds) of the set of evenly spaced aggregation intervals per day, starting at 00:00:00 (midnight). For example, a value of 900 (15 minutes) indicates that every day should be broken into 96 15-minute intervals.

When clock aligned data is being transmitted, the interval in question is identified by the start time and (optional) duration interval value, represented according to the ISO8601 standard. All "per-period" data (e.g. energy readings) should be accumulated (for "flow" type measurands such as energy), or averaged (for other values) across the entire interval (or partial interval, at the beginning or end of a Transaction), and transmitted (if so enabled) at the end of each interval, bearing the interval start time timestamp.

A value of "0" (numeric zero), by convention, is to be interpreted to mean that no clock-aligned data should be transmitted.
0RW
22
6Core Profile9.1.6ConnectionTimeOutrequiredRWintegersecondsInterval *from beginning of status: 'Preparing' until incipient Transaction is automatically canceled, due to failure of EV driver to (correctly) insert the charging cable connector(s) into the appropriate socket(s). The Charge Point SHALL go back to the original state, probably: 'Available'.30RW
23
7Core Profile9.1.7ConnectorPhaseRotationrequiredRWCSLThe phase rotation per connector in respect to the connector’s electrical meter (or if absent, the grid connection). Possible values per connector are:
NotApplicable (for Single phase or DC Charge Points)
Unknown (not (yet) known)
RST (Standard Reference Phasing)
RTS (Reversed Reference Phasing)
SRT (Reversed 240 degree rotation)
STR (Standard 120 degree rotation)
TRS (Standard 240 degree rotation)
TSR (Reversed 120 degree rotation)

R can be identified as phase 1 (L1), S as phase 2 (L2), T as phase 3 (L3).

If known, the Charge Point MAY also report the phase rotation between the grid connection and the main energymeter by using index number Zero (0).

Values are reported in CSL, formatted: 0.RST, 1.RST, 2.RTS
Unknown,Unknown,Unknownphase rotation not supported
24
8Core Profile9.1.8ConnectorPhaseRotationMaxLengthoptionalRintegerMaximum number of items in a ConnectorPhaseRotation Configuration Key.Not supported
25
9Core Profile9.1.9GetConfigurationMaxKeysrequiredRintegerMaximum number of requested configuration keys in a GetConfiguration.req PDU.30R
26
10Core Profile9.1.10HeartbeatIntervalrequiredRWintegersecondsInterval of inactivity (no OCPP exchanges) with central system after which the Charge Point should send a Heartbeat.req PDU86400RW
27
11Core Profile9.1.11LightIntensityoptionalRWinteger%Percentage of maximum intensity at which to illuminate Charge Point lighting100to be supported
28
12Core Profile9.1.12LocalAuthorizeOfflinerequiredRWbooleanwhether the Charge Point, when offline, will start a transaction for locally-authorized identifiers.TRUERW
29
13Core Profile9.1.13LocalPreAuthorizerequiredRWbooleanwhether the Charge Point, when online, will start a transaction for locally-authorized identifiers without waiting for or requesting an Authorize.conf from the Central SystemFALSERW
30
14Core Profile9.1.14MaxEnergyOnInvalidIdoptionalRWintegerWhMaximum energy in Wh delivered when an identifier is invalidated by the Central System after start of a transaction.Not supported
31
15Core Profile9.1.15MeterValuesAlignedDatarequiredRWCSLClock-aligned measurand(s) to be included in a MeterValues.req PDU, every ClockAlignedDataInterval secondsCurrent.Import,Current.Offered,Voltage,Power.Active.Import,Energy.Active.Import.Register, TemperatureRW
32
16Core Profile9.1.16MeterValuesAlignedDataMaxLengthoptionalRintegerMaximum number of items in a MeterValuesAlignedData Configuration Key.8R
33
17Core Profile9.1.17MeterValuesSampledDatarequiredRWCSLSampled measurands to be included in a MeterValues.req PDU, every MeterValueSampleInterval seconds. Where applicable, the Measurand is combined with the optional phase; for instance: Voltage.L1Current.Import,Current.Offered,Voltage,Power.Active.Import,Energy.Active.Import.Register, TemperatureRW
34
18Core Profile9.1.18MeterValuesSampledDataMaxLengthoptionalRintegerMaximum number of items in a MeterValuesSampledData Configuration Key.8R
35
19Core Profile9.1.19MeterValueSampleIntervalrequiredRWintegersecondsInterval between sampling of metering (or other) data, intended to be transmitted by "MeterValues" PDUs. For charging session data (ConnectorId>0), samples are acquired and transmitted periodically at this interval from the start of the charging transaction.

A value of "0" (numeric zero), by convention, is to be interpreted to mean that no sampled data should be transmitted.
60RW
36
20Core Profile9.1.20MinimumStatusDurationoptionalRWintegersecondsThe minimum duration that a Charge Point or Connector status is stable before a StatusNotification.req PDU is sent to the Central System.0RW
37
21Core Profile9.1.21NumberOfConnectorsrequiredRintegerThe number of physical charging connectors of this Charge Point.1R
38
22Core Profile9.1.22ResetRetriesrequiredRWintegertimesNumber of times to retry an unsuccessful reset of the Charge Point.2RW
39
23Core Profile9.1.23StopTransactionOnEVSideDisconnectrequiredRWbooleanWhen set to true, the Charge Point SHALL administratively stop the transaction when the cable is unplugged from the EV.TRUERW
40
24Core Profile9.1.24StopTransactionOnInvalidIdrequiredRWbooleanwhether the Charge Point will stop an ongoing transaction when it receives a non- Accepted authorization status in a StartTransaction.conf for this transactionTRUERW
41
25Core Profile9.1.25StopTxnAlignedDatarequiredRWCSLClock-aligned periodic measurand(s) to be included in the TransactionData element of StopTransaction.req MeterValues.req PDU for every ClockAlignedDataInterval of the Transaction""RW
42
26Core Profile9.1.26StopTxnAlignedDataMaxLengthoptionalRintegerMaximum number of items in a StopTxnAlignedData Configuration Key.0to be supported
43
27Core Profile9.1.27StopTxnSampledDatarequiredRWCSLSampled measurands to be included in the TransactionData element of StopTransaction.req PDU, every
MeterValueSampleInterval seconds from the start of the charging session
""RW
44
28Core Profile9.1.28StopTxnSampledDataMaxLengthoptionalRintegerMaximum number of items in a StopTxnSampledData Configuration Key.8R
45
29Core Profile9.1.29SupportedFeatureProfilesrequiredRCSLA list of supported Feature Profiles. Possible profile identifiers: Core, FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging and RemoteTrigger.Core,FirmwareManagement,LocalAuthListManagement,Reservation,SmartCharging,RemoteTriggerR
46
30Core Profile9.1.30SupportedFeatureProfilesMaxLengthoptionalRintegerMaximum number of items in a SupportedFeatureProfiles Configuration Key.Not supported
47
31Core Profile9.1.31TransactionMessageAttemptsrequiredRWintegertimesHow often the Charge Point should try to submit a transaction-related message when the Central System fails to process it.1to be supported
48
32Core Profile9.1.32TransactionMessageRetryIntervalrequiredRWintegersecondsHow long the Charge Point should wait before resubmitting a transaction-related message that the Central System failed to process.30to be supported
49
33Core Profile9.1.33UnlockConnectorOnEVSideDisconnectrequiredRWbooleanWhen set to true, the Charge Point SHALL unlock the cable on Charge Point side when the cable is unplugged at the EV.TRUERW
50
34Core Profile9.1.34WebSocketPingIntervaloptionalRWintegersecondsOnly relevant for websocket implementations. 0 disables client side websocket Ping/Pong. In this case there is either no ping/pong or the server initiates the ping and client responds with Pong. Positive values are interpreted as number of seconds between pings. Negative values are not allowed. ChangeConfiguration is expected to return a REJECTED result.0RW
51
35Local Auth List Management Profile9.2.1LocalAuthListEnabledrequiredRWbooleanwhether the Local Authorization List is enabledTRUERW
52
36Local Auth List Management Profile9.2.2LocalAuthListMaxLengthrequiredRintegerMaximum number of identifications that can be stored in the Local Authorization List48R
53
37Local Auth List Management Profile9.2.3SendLocalListMaxLengthrequiredRintegerMaximum number of identifications that can be send in a single SendLocalList.req48R
54
38Reservation Profile9.3.1ReserveConnectorZeroSupportedoptionalRbooleanIf this configuration key is present and set to true: Charge Point support reservations on connector 0.TRUER
55
39Smart Charging Profile9.4.1ChargeProfileMaxStackLevelrequiredRintegerMax StackLevel of a ChargingProfile. The number defined also indicates the max allowed number of installed charging schedules per Charging Profile Purposes.8R
56
40Smart Charging Profile9.4.2ChargingScheduleAllowedChargingRateUnitrequiredRCSLA list of supported quantities for use in a ChargingSchedule. Allowed values: 'Current' and 'Power'Current,PowerRW
57
41Smart Charging Profile9.4.3ChargingScheduleMaxPeriodsrequiredRintegerMaximum number of periods that may be defined per ChargingSchedule.24R
58
42Smart Charging Profile9.4.4ConnectorSwitch3to1PhaseSupportedoptionalRbooleanIf defined and true, this Charge Point support switching from 3 to 1 phase during a Transaction.FALSEto be supported
59
43Smart Charging Profile9.4.5MaxChargingProfilesInstalledrequiredRintegerMaximum number of Charging profiles installed at a time10R
60
61
62
Custom MessageAccessibilityDescriptionDefault Setting ValueNote
63
Cst_BackendUrlRWChange the Central system URL, eg: wss://ocpp-toolkit-api.monta.app.
After the changes, 'RebotRequired' response is triggered, and it will take effect after restarting.
" "Only for NexBlue's internal useCannot be modified while charging
64
Cst_ChargeBoxIdRChange the Charge box ID, default as SN.
After the changes, 'RebotRequired' response is triggered, and it will take effect after restarting.
" "Only for NexBlue's internal use
65
Cst_rssi_valuesRThe signal strength of the WiFi/Cellular based on the connectivity.-99Only for NexBlue's internal use
66
Cst_NotNetworkMeterValueSampleIntervalRWSampling interval for metervalue when the charger is offline.0Only for NexBlue's internal use
67
Cst_FreeVendActiveRWPlug in to start charging and unplug to stop.FALSEOnly for NexBlue's internal use
68
Cst_FreeVendIdTagRWWhen the value is empty, it is represented as "A0000000"."A0000000"Only for NexBlue's internal use
69
Cst_CaCertRWCertification" "Only for NexBlue's internal use
70
Cst_ReconnectIntervalRWThe interval of reconnection30Only for NexBlue's internal use
71
Cst_PreBoot TransactionsRWWhether or not a transaction can be initiated before the BootNotification successfully completes.FALSEOnly for NexBlue's internal use
72
Cst_Silent Offline TransactionsRWIf the EVSE goes offline, whether or not it can continue to charge without sending StartTx / StopTx to the server when going online again.FALSEOnly for NexBlue's internal use
73
Cst_Authorization TimeoutRWHow long the EVSE tries the Authorize request before it enters offline mode.20Only for NexBlue's internal use
74
Cst_MeterValueCacheSizeRWHow many data can be cached in MeterValue.1Only for NexBlue's internal use
75
Cst_StopTxnDataCapturePeriodicRWWhether or not to enable stop Txn Data timer logging.FALSEOnly for NexBlue's internal use
76
Cst_ModemMeterValueSampleIntervalRWSampling interval for metervalue when the charger is connected to cloud via 4G. Default close.0Only for NexBlue's internal use
77
Cst_ModemStateRWhether or not the charger is connected to cloud via 4G.""Only for NexBlue's internal use
78
Cst_lock_stateRObtain the lock status: "True" indicates that the lock is engaged, while "False" signifies that it is disengaged.""Only for NexBlue's internal use
79
Cst_NetworkStateRWhether or not the charger is connected to cloud""Only for NexBlue's internal use
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100