SITE IDLOCATIONAL IDENTIFIERLEAD GOOSENECK CURRENTLY PRESENT?CURRENT STREET SIDE SERVICE LINE MATERIALWAS STREET SIDE SERVICE LINE MATERIAL EVER PREVIOUSLY LEAD?STREET SIDE SERVICE LINE SIZESTREET SIDE SERVICE LINE INSTALL DATECURRENT PROPERTY SIDE SERVICE LINE MATERIALPROPERTY SIDE SERVICE LINE SIZEPROPERTY SIDE SERVICE LINE INSTALL DATEBUILDING TYPEPOINT-OF-ENTRY OR POINT-OF-USE TREATMENT PRESENT?BUILDING PLUMBING MATERIAL 1BUILDING PLUMBING MATERIAL 2BUILDING PLUMBING MATERIAL INSTALL DATECOMMENTSBASIS OF STREET SIDE MATERIAL CLASSIFICATIONWAS STREET SIDE MATERIAL FIELD VERIFIED?DATE OF STREET SIDE FIELD VERIFICATION, IF APPLICABLEMETHOD OF STREET SIDE FIELD VERIFICATION, IF APPLICABLEBASIS OF PROPERTY SIDE MATERIAL CLASSIFICATION WAS PROPERTY SIDE MATERIAL FIELD VERIFIED?DATE OF PROPERTY SIDE FIELD VERIFICATION, IF APPLICABLEMETHOD OF PROPERTY SIDE FIELD VERIFICATION, IF APPLICABLE NOTES ON BASIS OF MATERIAL CLASSIFICATION
2
N6598 Leicht rdNCN3/4"1970C3/4"SFNUNKUNKInstallation recordNField inspection onlyYVisual insp at meter
3
N6598 Leicht rdNCN3/4"2000C3/4"2004SFNUNKUNKInstallation recordNInstalled after lead banYVisual insp at meter
4
N6585 Leicht rdNCN3/4"1970c3/4"SFNUNKUNKInstallation recordNField inspection onlyYVisual insp at meter
5
N6588 Leicht rdNCN3/4"1970C3/4"SFNUNKUNKInstallation recordNField inspection onlyYVisual insp at meter
6
N6574 Leicht rdNCN3/4"1970C3/4"SFNUNKUNKInstallation recordNField inspection onlyYVisual insp at meter
7
N6575 Leicht rdNCN3/4"1970C3/4"SFNUNKUNKInstallation recordNField inspection onlyYVisual insp at meter
8
N6568 Leicht rdNCN3/4"2022P3/4"2022SFNO2022Field inspection onlyY2022Visual insp during install or repair Installed after lead banY2022Visual insp during install or repair
9
N6565 Leicht rdNCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyY2023Visual insp at meter
10
N6555 Leicht rdNCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
11
N6543 Leicht rdNCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
12
N6544 Leicht rdNCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
13
N9942 Hwy.54NCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
14
N9952 Hwy.54NCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
15
N6526 Hwy.54NCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
16
W9918 Airport Rd.
NCN3/4"1970C3/4"SFNUNKInstallation recordNField inspection onlyYVisual insp at meter
17
W9926 Airport Rd.
NCN3/4"1970C3/4"SFNUNKInstallation recordNInstallation recordYVisual insp at meter
18
W9814 Airport Rd.
NDIN6"1995DI6"1995NONRESNC1995Diameter > 2 inchesYVisual insp at meterDiameter > 2 inchesY2024Visual insp at meter
19
N6520 Lumberjack Guy Rd.
NCN3/4"2006C3/4"2006NONRESNC2006Installation recordNInstalled after lead banY2024Visual insp at meter
20
N6564 Lumberjack Guy Rd.
NCN3/4"2011C3/4"2011NONRESNO2011Installation recordNVisual insp at meterInstalled after lead banY2024Visual insp at meter
21
N6571 Lumberjack Guy Rd.
NDIN6"2013DI6"2013NONRESYC2013Diameter > 2 inchesYVisual insp during install or repair Diameter > 2 inchesY2024Visual insp during install or repair
22
N6520 Lumberjack Guy Rd.
NDIN6"2002DI6"2002NONRESNC2002Diameter > 2 inchesNDiameter > 2 inchesY2024Visual insp at meter
23
W9802 Airport Rd.
NCN3/4"2003C3/4"2003NONRESNC2003Installation recordNField inspection onlyY2024Visual insp at meter
24
W9850 Airport Rd.
NCN1 1/2"2000C1 1/2"2002NONRESNC2002Installation recordNField inspection onlyY2024Visual insp at meter
25
N6431 Lumberjack Guy Rd.
NCN1"2011C1"2011SCH/DCNC2011Installation recordNInstalled after lead banY2024Visual insp at meter
26
W9814 Airport Rd.
NCN3/4"2002C3/4"2002NONRESNC2002Installation recordNInstalled after lead banY2024Visual insp at meter
27
W9790 Airport Rd.
NCN3/4"1999C3/4"1999NONRESNC1999Installation recordNField inspection onlyY2024Visual insp at meter
28
W9944 Airport Rd.
NCN1"1970C1"1970NONRESNC1970Installation recordNField inspection onlyY2024Visual insp at meter
29
N6517 Bagan Rd.
NCN3/4"1970C3/4"1970SFNC1970Installation recordNInstallation recordN
30
N10017 Hwy. 54NCN3/4"1973C3/4"1973OTHNUNKNo bld. on siteInstallation recordNOther - describe in notesY2020Other - describe in notes
Located curbstop and lateral on property, Recorded property side material at this time.
31
W10005 Hwy.54NCN3/4"1973C3/4"1973SFNCInstallation recordNInstallation recordN
32
W10003 Hwy.54NCN3/4"1973C3/4"1973NONRESNCInstallation recordNField inspection onlyY2024Visual insp at meter
33
W10090 Hwy.54NDIN4"1997DI4"1997NONRESNC1997Diameter > 2 inchesNDiameter > 2 inchesY2024Visual insp at meter
34
W10120 Hwy.54NCN3/4"1998C3/4"1998NONRESNC1998Installed after lead banNField inspection onlyY2024Visual insp at meter
35
W10170 Hwy.54NDIN6"1997DI6"1997NONRESNC1997Diameter > 2 inchesNDiameter > 2 inchesY2024Visual insp at meter
36
800 a OasisNCN1"1986C1"1986NONRESNC1986Installation recordNField inspection onlyY2024Visual insp at meter
37
800 b OasisNCN2"2021P2"2021NONRESNO2021
Water only plumbed into Bld. for metering
Field inspection onlyY2021Visual insp during install or repair Installed after lead banY2021Visual insp during install or repair
Water is only plumbed into Bld. for metering.
38
400 OasisNCN2"1972C2"1972NONRESNC1972Field inspection onlyYVisual insp at meterField inspection onlyY2024Visual insp at meter
39
200 OasisNDIN4"1972DI4"1972NONRESNC1972Diameter > 2 inchesY2024Visual insp at meterDiameter > 2 inchesY2024Visual insp at meter
40
600 OasisNDIN4"1972DI4"1972NONRESNCO1972
Ductile Iron and Copper inside
Diameter > 2 inchesY2024Visual insp at meterDiameter > 2 inchesY2024Visual insp at meter
41
W10124 Hwy.54NCN3/4"1998NNo Bld. on siteInstallation recordN
42
100 OasisNPN1"2021P1"2021NNo Bld. on siteInstalled after lead banY2021Visual insp during install or repair Installed after lead banY2021Visual insp during install or repair
43
210 ParkNCN3/4"2008C3/4"2008MFNC2008Installed after lead banNInstalled after lead banN
44
210b ParkNCN3/4"2008C3/4"2008MFNC2008Installed after lead banNInstalled after lead ban
45
214 ParkNCN3/4"1972C3/4"1972SFNCInstallation recordNInstallation recordN
46
218 ParkNCN3/4"1974C3/4"1974SFNCInstallation recordNInstallation recordN
47
217 ParkNCN3/4"1974C3/4"1974SFNCOInstallation recordNInstallation recordN
48
221 ParkNCN3/4"1972C3/4"1972SFNCInstallation recordNInstallation recordN
49
225 ParkNCN3/4"1972C3/4"1972SFNCInstallation recordNInstallation recordN
50
226 ParkNCN3/4"1974C3/4"1974SFNCInstallation recordNInstallation recordN
51
227 ParkNCN3/4"1974C3/4"1974SFNUNKField inspection onlyY2022Visual insp at meterField inspection onlyY2022Visual insp at meter
52
231 ParkNCN3/4"1974C3/4"1974SFNO2000Field inspection onlyY2022Visual insp at meterField inspection onlyY2022Visual insp at meter
53
505 3rdNCN3/4"1972C3/4"1972SFNUNK1972Installation recordNN
54
500 3rdNCN3/4"2015P3/4"2015SFNO2015Installed after lead banNN
55
642 3rdNPN6"2015P6"2015OTHNOO2015Installed after lead banNInstalled after lead banY2022Visual insp at meterOld folks home
56
301 parkNCN3/4"1972C3/4"1972SFNUNK2001Installation recordNInstallation recordN
57
404 3rdNCN3/4"2015C3/4"2015SFNUNK2015Installation recordNInstallation recordN
58
311 ParkNCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
59
316 ParkNCN3/4"1972C3/4"1972SFNUNK1995Installation recordNInstallation recordN
60
319 ParkNCN3/4"1972C3/4"1972SFNUNK1975Installation recordNInstallation recordN
61
318 ParkNCN3/4"1986C3/4"1986SFNC1986Installation recordY2021Visual insp at meterField inspection onlyY2021Visual insp at meter
62
327 ParkNCN3/4"1970C3/4"1972SFNC1972Installation recordNInstallation recordN
63
324 Park NCN3/4"1988C3/4"1988SFNC1988Installation recordNInstallation recordN
64
430 4thNCN3/4"2015P1"2015SFNO2015Installed after lead banNInstalled after lead banN
65
411 3rdNCN3/4"1972C3/4"1972SFNCInstallation recordNN
66
401 3rdNCN3/4"1979C3/4"1979SFNUNKInstallation recordNInstallation recordN
67
403 3rdNCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
68
317 3rdNCN3/4"1972C3/4"1972SFNCO2021
House was remodeled and replumbed with plastic
Field inspection onlyY2021Visual insp at meterField inspection onlyY2021Visual insp at meter
69
313 3rdNCN3/4"1979C3/4"1979SFNUNKInstallation recordNInstallation recordN
70
306 SterlingNCN3/4"1972C3/4"1972SFNCOField inspection onlyY2022Visual insp at meterField inspection onlyY2022Visual insp at meter
71
310 3rdNCN3/4"1974C3/4"1974SFNUNKInstallation recordNN
72
311 3rdNCN3/4"2000C3/4"2000SFNUNK2000Installed after lead banNInstalled after lead banN
73
307 3rdNCN3/4"1974C3/4"1974SFNUNKInstallation recordNInstallation recordN
74
306 3rdNCN3/4"1974C3/4"1974SFNCOField inspection onlyY2022Visual insp at meterField inspection onlyN2022Visual insp at meter
75
301 Arm.NCN3/4"1974C3/4"1974SFNUNKUNKInstallation recordNInstallation recordN
76
303 3rdNCN3/4"1973C3/4"1973SFNUNK1973Installation recordNInstallation recordN
77
213 3rdNCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
78
205 3rdNCN3/4"2009P1"2009SFNO2009Installation recordNInstallation recordN
79
201 3rdNCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
80
111 3rdNCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
81
301 GebhardtNCN3/4"1973C3/4"1973SFNUNKInstallation recordNInstallation recordN
82
300 GebhardtNCN1"1977C1"1977NONRESNCO1977Installation recordY2023Visual insp at meterField inspection onlyY2023Visual insp at meter
83
110 W. 3rdNCN3/4"1977C3/4"1977SFNUNK1977Installation recordNCustomer self idInstallation recordN
84
130 W. 3rdNCN3/4"1973NInstallation recordN
No longer Bld. on site
85
134 W. 3rdNCN3/4"1973C3/4"1973SFNUNKInstallation recordNInstallation recordN
86
135 W. 3rdNCN3/4"1990C3/4"1990SFNUNKInstalled after lead banNInstalled after lead banN
87
101 4thNCN3/4"1972C3/4"1972SFNCOField inspection onlyY2021Visual insp at meterField inspection onlyY2021Visual insp at meter
88
117 4thNCN3/4"1973C3/4"1973SFNCInstallation recordNInstallation recordN
89
209 4thNCN3/4"1973C3/4"1973SFNCOInstallation recordY2022Visual insp at meterField inspection onlyY2022Visual insp at meter
90
210 4thNCN3/4"1972C3/4"1972SFNCInstallation recordY2020Visual insp during install or repair SL repair/replace recordY2020Visual insp during install or repair
91
308 4thNCN3/4"2015P3/4"2015NONRESNCO2015Field inspection onlyY2023Visual insp at meterField inspection onlyY2023Visual insp at meter
92
305 4thNCN3/4"2004C3/4"2004SFNUNK2004Installed after lead banNInstalled after lead banN
93
326 Sterl.NCN3/4"1972C3/4"1972SFNCInstallation recordNInstallation recordN
94
415 4thNCN3/4"1998P1"1998SFNO1998Installation recordNInstallation recordN
95
325 Sterl.NCN3/4"1979C3/4"1979SFNC1979Installation recordNInstallation recordN
96
318 Sterl.NCN3/4"1972C3/4"1972SFNC1971Installation recordYCustomer self idInstallation recordYCustomer self id
97
312 Sterl.NCN3/4"1972C3/4"1972SFNUNKInstallation recordNInstallation recordN
98
317 Sterl.NCN3/4"1978C3/4"1978SFNCO1978Installation recordY2020Visual insp at meterInstallation recordY2020Visual insp at meter
99
222 MeadeNCN3/4"1973C3/4"1973SFNCInstallation recordNInstallation recordN
100
223 MeadeNCN3/4"1973C3/4"1973SFNUNKInstallation recordNInstallation recordN