| A | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Cycle | 2014/2015 | 2015/2016 | 2016/2017 | 2017/2018 | 2018/2019 | 2019/2020 | 2020/2021 | 2021/2022 | ||||||||
2 | A cycle goes from April 1st to March 31st (essentially from HIMSS Showcase to HIMSS Showcase to assess lessons learned). This is not in alignment with the PCD domain planning calendar. | Cycle 9 | Cycle 10 | Cycle 11 | Cycle 12 | Cycle 13 | Cycle 14 | Cycle 15 | Cycle 16 | ||||||||
3 | Architecture | ||||||||||||||||
4 | |||||||||||||||||
5 | Rebranding TF to cover PCD, PCH, DPI. | ||||||||||||||||
6 | HL7 v3 (FHIR) WP MDISS security WP in review DPI - effort/discussions CNS (on hold) | HL7 v2.8.2 v2.9, HL7 v3 (device acquired data in CDA, FHIR for device data) MOU established with MDISS for cybersecurity | HL7 v2.8.2 v2.9, HL7 v3 (device acquired data in CDA, FHIR for device data) MOU established with MDISS for cybersecurity DPI CNS | HL7 v2.9, HL7 v3 (device acquired data to CDA), FHIR for device data), Work proceeding on MOU with MDISS for cybersecurity, DPI, CNS | |||||||||||||
7 | Device-Enterprise Communication | ||||||||||||||||
8 | Now Restrospective Data Query (RDQ) (currently insufficient demand for vendor implementations or Connetathon participation) | ||||||||||||||||
9 | SPD/DOF - PCD-02: Subscribe to Patient Data at FT (still starved for testing, WCM couldn't drive resurgence), could updating document improve the desire to test it, advantage is that filtering can be done dynamically | ||||||||||||||||
10 | Expand ACM further within PCD. Ex. Integrate with MEM DMC observations and advisory. Expand ACM into IHE - ex. ITI's NAV profile to notify people of document availability. Also pharmacy, lab, and radiology are candidates where workflows in need of alerting exist | ITI parallel activity proposed mACM (uses FHIR for PCD-04) PCD-15 (DMIO) new for MEMDMC DMIR to DMIC PCD-16 new for MEMLS (LOR) LSR to LOC Resurrection of PCD-05, PRT in PCD-04 for ACM | Add profile specific options to DEC, ACM, for WCM Add profile specific options to MEMDMC (for ePHI) | Need to add profile specific option to IDCO for WCM Add profile specific option for ePHI to DEC, already in ACM | Tested PCD-O5 at Connectathon | Quiet Hospital initiative expanding use of PCD-05 and PCD-07 | Expand discussions with FDA and regulatory agencies outside the US. | ||||||||||
11 | CP'd ACM to add Alert Inventory as re-send of currently outstanding alerts using PCD-04 with Continue indication | Smart Alarms - No new transactions, maybe a new actor between multiple ARs & AM - Smart Alarms too broad a term: (multi-alarm filtering/prioritization) vs new Derived Alarms (algs for such decisions) would take in PCD-01s and PCD-04s and produce a PCD-04 | |||||||||||||||
12 | Restrospective Data Query (RDQ) (currently insufficient demand for vendor implementations or Connetathon participation) | ||||||||||||||||
13 | EC (Event Comm) to draw from IPEC, etc. | IPEC at FT. EC (Event Comm). | IPEC at FT | ||||||||||||||
14 | DEC FHIR option | ||||||||||||||||
15 | Specializations: pumps, vents, physio mons --Migrate pump info from IPEC to Specializations | Specializations: pumps, vents, physio mons (already 1st in PCD TF vol 3) Information should come from computable model and not narrative text in Word doc. | |||||||||||||||
16 | Device Context Management | ||||||||||||||||
17 | |||||||||||||||||
18 | Draft WP review at Fall F2F | PCIM WP release | PCIM profile is a work in process | PCIM profile release for public comment | PCIM Trial Implementation | PCIM Trial Implementation | |||||||||||
19 | Device Order Management | ||||||||||||||||
20 | |||||||||||||||||
21 | Syringe and PCA added to PIV at FT | ||||||||||||||||
22 | Joint Pharm-PCD Med Admin WP released | ||||||||||||||||
23 | Multi-component add-mixtures - a PIV enhancement | Multi-component add-mixtures - need to plan a PIV enhancement release | |||||||||||||||
24 | Multi-component add-mixtures - a PIV enhancement | Multi-step infusion - need to plan a PIV enhancement release | Update to PCD-03 for Multi-step infusion | ||||||||||||||
25 | Multi-component add-mixtures - a PIV enhancement | Infusion nomenclature plan to be released in IEEE 11073-10101b | Infusion nomenclature plan to be released in IEEE 11073-10101b | ||||||||||||||
26 | Medical Equipment Management (MEM) | ||||||||||||||||
27 | MEM Cyber Security and Patching (joint w/MDISS) WPs released | ||||||||||||||||
28 | MEMLS TI in 2015 C'thon | MEMDMC nomenclature in IEEE 11073-10101b | MEMDMC at FT | MEMLS at FT | |||||||||||||
29 | MEMDMC TI in 2015 C'thon | MEMLS nomenclature in IEEE 11073-10101b | MEMDMC at FT | MEMDMC at FT | |||||||||||||
30 | MEMDMC WP on device remote command and control (IEEE and AAMI also active in remote device control) | MEMDMC WP on device remote command and control (IEEE and AAMI also active in remote device control) | |||||||||||||||
31 | Point of Care | ||||||||||||||||
32 | |||||||||||||||||
33 | UML model for IEEE 11073-10201 (available from NIST) | ||||||||||||||||
34 | DIM and containment model editor V1 (being managed by NIST) | DIM and containment model editor for -20601 (being managed by NIST) | DPI WP released | ||||||||||||||
35 | |||||||||||||||||
36 | |||||||||||||||||
37 | Symmetric Communication (Pump - Physio mon awareness for auto-pgm adjustment) | ||||||||||||||||
38 | Content Management | 10101a start of balloting in mid-Nov 2014 - proposed | 10101a start of balloting - actual Mid-April 2015 | ||||||||||||||
39 | C'thon 2016 using 10101a terms | ||||||||||||||||
40 | Move 10101a into NIST RTMMS (Nov 2015), 1st use C'thon 2016 (not all co-constraints were exercised) | Develop 10101b to include infusion pumps, vent modes, MEMDMC, MEMLS, and add'l new terms (draft Q4'2016) | Develop 10101b to include infusion pumps, vent modes, MEMDMC, MEMLS, and add'l new terms (draft Q4'2016) | ||||||||||||||
41 | Develop alert/events for inclusion into 10101b (draft Q2'2017) | Develop alert/events for inclusion into 10101b (draft Q2'2017) | |||||||||||||||
42 | Ability to allocate and lock-in new codes for -10101b | ||||||||||||||||
43 | Developed mapping from IEEE to LOINC (not all of 10101 planned to be mapped) | IEEE to LOINC mappings for 590 terms (with assistance from Regenstrief) | |||||||||||||||
44 | |||||||||||||||||
45 | |||||||||||||||||
46 | |||||||||||||||||
47 | |||||||||||||||||
48 | Alert basic attributes in 10101a | ||||||||||||||||
49 | Resume work on Rosetta for Events and Alerts | Continue work on Rosetta for Events and Alerts | Continue work on Rosetta for Events and Alerts | ||||||||||||||
50 | |||||||||||||||||
51 | |||||||||||||||||
52 | WCM demo'd in DEC at C'thon | WCM demo'd in DEC at C'thon Effort to refine WCM | Updated WCM TI, samples/sec are integral | Integrate numeric codes for WCM specific terms into -10101b | |||||||||||||
53 | |||||||||||||||||
54 | Pump specializations released in PCD TF Vol 3 (wouldn't this be better done through automation rather than narrative text?) | ||||||||||||||||
55 | Ventilator specialization terms (minus ventilator mode) in RTMMS and as XML file and in -10101a (not PCD TF Vol 3) | ||||||||||||||||
56 | Rosetta --> Snomed and/or LOINC Equivalency Mapping proposed | Work on IEEE to LOINC mapping | |||||||||||||||
57 | Coordination Efforts | ||||||||||||||||
58 | - Continua (now PCHA) | 1. Smart Home 2. Long Term Care 3. Physician Office 4. Sub-Acute Care | Sending PCHA records via CDA R2 (PCC) Investigating command and control, possibly over a different transport layer | PCHA planning on making encoding also available in FHIR | Merge into IHE rename PCD Domain as Devices Domain with PCD, PCH and DPI sub domains | ||||||||||||
59 | - ONC | Meaningful Use - Certification C4MI comments into ONC, HIMSS comments to ONC re standards | IHE PCD DEC listed in Interoperability Standards Advisory (ISA) 2017 | ||||||||||||||
60 | - Connect | ||||||||||||||||
61 | - SHARP (NIH Quantum 5yr grant to develop an ICE) | ||||||||||||||||
62 | - ICE | Efforts displaced into DPI and tooling efforts | |||||||||||||||
63 | - IHE (cross domain or DCC activities) | IHE cross domain WG on workflow in profiles (not specific to PCD profiles) | ACM for Lab critical results notifications (lab automation system simply becomes an ACM AR) Coordinating with Patient Care Coordination (PCC) on Point of Care Medical Device Tracking (PMDT) | ||||||||||||||
64 | - AAMI | a lot of ICE stuff moving to AAMI WG 3 | AAMI ICE Data logger (once further along, assess against RDQ) | ||||||||||||||
65 | - VA | POI specialization doc needs to be transformed for integration into PCD TF Vol 3 | POI specialization needs resources and needs to be reviewed to see if automation is a better solution | ||||||||||||||
66 | - AAMI / UL2800 | UL2800 a WIP - slow | |||||||||||||||
67 | - Certification efforts | IHE International CaSC - initially only DEC and PIV (initially using NIST tools) HIMSS Concert (not using NIST tools) | |||||||||||||||
68 | CMI (formerly C4MI) | They are looking to specify a secure IHE PCD transport | |||||||||||||||
69 | Quality | ||||||||||||||||
70 | IEC 80001 | 80001-2-5 released | amendment release regarding alarms | ||||||||||||||
71 | IEC 60601- | CP to ACM to better align with current version of 60601-1-8 | Harmonization between 60601-1-8 and Quiet Hospital | ||||||||||||||
72 | SESMDI | White paper on Safe Effective and Secure Medical Device Interoperability using SDPi +FHIR | |||||||||||||||
73 | IEC 60601- | Potential for standards update for smart alarming? | |||||||||||||||
74 | |||||||||||||||||
75 | |||||||||||||||||
76 | |||||||||||||||||
77 | |||||||||||||||||
78 | |||||||||||||||||
79 | |||||||||||||||||
80 | |||||||||||||||||
81 | |||||||||||||||||
82 | |||||||||||||||||
83 | |||||||||||||||||
84 | |||||||||||||||||
85 | |||||||||||||||||
86 | |||||||||||||||||
87 | |||||||||||||||||
88 | |||||||||||||||||
89 | |||||||||||||||||
90 | |||||||||||||||||
91 | |||||||||||||||||
92 | |||||||||||||||||
93 | |||||||||||||||||
94 | |||||||||||||||||
95 | |||||||||||||||||
96 | |||||||||||||||||
97 | |||||||||||||||||
98 | |||||||||||||||||
99 | |||||||||||||||||
100 |