Unit Modification Chart
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

View only
 
 
ABCDEFGHIJKLMNOPQRSTUVWXY
1
All owners, and only owners, must apply for approval of any modification to their unit other than interior painting.
Absolutely no mofication may start prior to written notice of approval to proceed.
2
AREA/TYPE
OF MODIFICATION
REQUIRED APPROVALSREQUIRED DOCUMENTS & SPECS
3
Village Green Mgmt OfficeDesign Review CommitteeBoard of DirectorsLAOHR
(*only if altering original material)
LADBS PermitRequirements & NotesReplacement Options
4
BATHROOM
5
Full Bathroom Remodel✓*See belowSee below
6
Floor Tile✓*- Photo of existing tile
- Sample/image of replacement (limit to 2)
- Matte finish (not gloss)
- Up to 4" of any shape
- Can include patterned motif
Original tile was manufactured by Tile Company of Zanesville, Ohio
7
Tub✓*- Photo of existing condition
- Sample/image of replacement
- like-for-like 30x60 tub
- For walk-in shower, owner needs to provide medical accommodation reason
8
Wall Tile✓*- Photo of existing tile
- Sample/image of replacement (limit to 2)
- Any finish
- Size: 4x4, 2x6, 2x8, 3x6, 3x12, 4x12, 4x16, penny-rounds and other mosaic tiles
(Originally it was 4-3/8x4-3/8 semi-matte)
9
Electrical- Plan of wiring if different than current
10
Plumbing- Plan of plumbing if different than current
11
Countertopn/aAny
12
SinkEnsure main water line is shut prior to work.Any
Original was Eljer sink with chrome legs
13
FaucetEnsure main water line is shut prior to work.Any
14
ToiletEnsure main water line is shut prior to work.Any
15
KITCHEN
16
Full Kitchen Remodel✓*See belowSee below
17
Cabinets✓*- Photo of existing cabinets. Include lower interior, particularly the ones next to dishwasher
- Sample/image of replacement
Shaker Style or flat-front Cabinets.
18
Countertop - Historic✓*- Photo of existing condition
- Sample/image of replacement
If original, must replace with like-for-like: wood and stainless steel. If not, any countertop can be installed.
19
Countertop - Non-historic- Photo of existing conditionAny
20
Backsplashn/aAny
21
Flooring (Older units might have asbestos in their linoleum)n/aAny
22
Rough Plumbing- Plan of plumbing if different than current
23
Sinkn/aAny
24
FaucetEnsure main water line is shut prior to work.Any
25
STRUCTURAL
26
Partition
(Non Load-Bearing Walls)
- Current floorplan
- Photos of existing wall
- Drawing of intended change
Demonstration that removal of the wall has been designed to not compromise lateral stability of the building with drawings and structural calculations and/or references to CBC that are stamped and signed by an architect or structural engineer.
27
Partition
(Load-Bearing Walls)
- Current floorplan
- Photos of existing wall
- Drawing of intended change
Demonstration that removal of the wall has been designed to support loads with drawings and structural calculations and/or references to CBC that are stamped and signed by an architect or structural engineer.
28
Ceiling Sound AbatementPermit for the demo. Permit for drywall. Inspections of plans. Inspections of insulation. Inspection of fasteners. Cardoza Drywall - Contractor
lic # 850766
19503 Ermine Street
Canyon Country, CA 91351
661.433.2427
310.739.7129
29
WOODWORK & CASINGS
30
Flooring - Refinish/Repairn/a
31
Flooring - Replacement- Photo of existing flooring condition
- Sample/image of replacement (see options)
DOWNSTAIRS: replace with mix of white/red oak parquet (match exisiting size) or install a floating floor over the existing floor.

UPSTAIRS & STAIRS: White oak planks (match original size)

Due to noise issues, for upstairs units, any flooring change other than HOA pre-approved carpet/pad specification will require review and approval by Acoustic Consultant.

https://drive.google.com/file/d/1jAsVaR3Djzg85IjNMFSPGjgKiRWRYft6/view?usp=sharing
32
Mahogony Railing- Photo of existing condition
- Sample/image of matching replacement
Like-for-like
33
Wall/Staircase Tongue & Groove Paneling- Photo of existing condition
- Sample/image of matching replacement
Like-for-like
34
DOORS & WINDOWS
35
Interior Doors- Photo of existing condition
- Sample/image of replacement doors

NOTE: please give the unused door to the VGOA office.
36
Patio Sliding Doors - Aluminum- Photo of existing door
Must use approved replacement options.
Info provided by the Office.
37
Patio Sliding Doors - French Doors
Changeout
- Photo of existing door
Must use approved replacement options.
Info provided by the Office.
https://www.thebenchmark.us/
38
Security Screen doorsMust use approved replacement options.Info provided by the Office
Greg Reevey at Screen Mobile
(714) 334-2868
You may purchase through office and make payments back to office
39
Screen DoorsMust use approved replacement options. Info provided by the Office
40
Window Screens
submit work order to office
Check with office for extrasCompanies who have made screens to fit our windows: https://www.tashmans.com/ Pioneer and Santa Monica Screen and Shades

5715 Venice Blvd.
Los Angeles 90019
310 204-4433
41
Inside Door HandlesIf you are changing the original brass door handles, please give them to the office
42
Exterior Door HardwareProvide sample of replacement hardware
43
Exterior Doors
submit work order to office
VGOA repairs and replaces all exterior doors
44
Windows
submit work order to office
VGOA repairs and replaces all exterior windows
45
Closet Doors- Provide image of current closet doorsDue to noise issues, upstairs unit must install floating closet doors due to acoustical issues

If you have the wood tongue/groove paneling, replacement must match like-for-like
46
ELECTRICALReplaced or new electrical appliances or fixtures shall not add to unit's electrical load

Documentation Requirements:
1) Photographs of all existing electrical appliances, lights and outlets and close-up photographs of the appliance labels showing model number
2) Electrical specifications for the appliances
3) A plan locating each item. This can be marked on a floorplan
47
Lighting- Lighting plan
- Lighting specs
- Panel specs
Recessed lighting must be ICAT-Rated (In Contact Air Tight)
48
Re-Wiring- Wiring plan, if different than original
- Panel specs
49
Panel- Wiring plan, if different than originalLike-for-like on voltage
50
Door Lights TimerProvided by the office at owner's expense
51
Porch Light
submit work order to office
Provided by the office. Limited quantity available
52
Garage Door Opener
submit work order to office
Garage Door Openers/installation are at owner's expense. If needed, the office will install electrical outlet to prepare garage for opener installation, at owner's expense.
53
Portable AC
submit work order to office
Owner will need to install plexiglass panel for window venting. Windows and window frames may not be harmed/altered. Owner can also fill WO for plexiglass installation.
55
Security Camera- Photos of where it will be installed
- Electrical wiring plan
56
Repairs to outlets, Changing fixtures/fans
submit work order to office
57
PLUMBING
58
Full Plumbing UpgradeSee below
59
Pipe/Drain relocation- Photos of where it will be installed
- Drawing of new lines
60
Supply/Drain Pipes for Washing Machine- Plan of change
- Drawing of plumbing lines
61
Vent- Photos of where it will be added
- Plan of change
- Drawing of vent lines
No new vent penetration allowed on the roof or exterior walls where it can be seen. Only allowed under fence line.
62
Tankless Water Heater- provide specs of unit
- (Exterior Unit) provide plan on where unit will be installed outside with pictures. Must be installed under fence line
- Interior Unit (gas), will need to vent to existing venting system.
- Interior Unit (electrical) must be able to handle the electrical load
63
Closet Water Heater
Like-for-like replacement
n/a
64
Closet Water Heater
electrical > gas
- Plan on how unit will be vented
No new vent penetration allowed on the roof or exterior walls, where it can be seen.
65
Stove venting/hood- Plan on how unit will be vented
No new vent penetration allowed on the roof or exterior walls, where it can be seen.
66
Piping/Drain (not interior wall)
submit work order to office
67
APPLIANCES & HVACReplaced or new electrical appliances or fixtures shall not add to unit's electrical load

Documentation Requirements:
1) Photographs of all existing electrical appliances, lights and outlets and close-up photographs of the appliance labels showing model number
2) Electrical specifications for the appliances
3) A plan locating each item. This can be marked on a floorplan
68
AC - Mini-split- Only allowed as medical accommodation
- Specs of the unit (must include electrical usage and dBA)
- Photo of where condensor will be installed.
Sound requirement of condensor must be 55dBA or less. Condensor must installed lower than fence/balcony line. Drain and electrical lines may not be visible. Cannot add electrical load to existing load.
69
Furnace
Like-for-like replacement
Must be able to use the same venting configuration.
70
Furnace
New configuration
Must work with the Office to determine venting configuration
71
Washer/Dryer- Current floorplan
- Photo of location
- Spec sheet of the unit, to include electrical usage
- Venting design (if installing gas dryer)
- Anticipated plumbing alterations (washer supply lines and drain line connection to appropriate sized drain)
No new vent penetration allowed on the roof. Exterior wall penetration allowed under fence line ONLY.
You may not add any more load to your existing electrical load. High efficiency appliances highly recommended. Sound pads required under unit.
We have seen sucess with LG combo washer dryers, both with space issues as well as electrical load. Please visit their website for more info.
72
Dishwasher- Current floorplan
- Photo of location
- Spec sheet of the unit, to include electrical usage
- Anticipated plumbing alterations
You may not add any more load to your existing load. High efficiency appliances highly recommended. Sound pads required
73
Stove: gas > electrical- Unit must be able to handle electrical load
74
Stove: electrical > gas- Floor plan with how gas lines will be installed
75
PATIO
76
Pavers- Images of existing pavers
- Drawing of where pavers will be placed
As per section 9.7 of the Handbook, if unit has original pavers, it must be restored back to its original. Please see section in Handbook for more details and other details.
77
Electrical OutletMust use licensed electrician
78
LightingMust use licensed electricianSection 9.12 ELECTRICAL; LIGHTING. No interior or exterior wiring changes or installation of exterior lights is permitted without the prior written consent of the Board.
79
Gas-line for fireplaceMust use licensed plumber
80
Metal Patio Security GateOffice must approve and provide specs
81
AwningFollow awning guidelines. Read Section 9.4 in Handbook.Follow awning guidelines
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
Loading...