| A | B | C | D | |
|---|---|---|---|---|
1 | ALL INPUTS ARE IN YELLOW -- CLEAR ALL CELLS ASSOCIATED WITH UNUSED EQUIPMENT | |||
2 | Compressed Air Compressor Curve Calculator With Equipment Inputs | |||
3 | COMPRESSORS | |||
4 | Comp 1 | Comp 2 | ||
5 | Effective date of CAGI sheet | 8/2009 | 8/2009 | |
6 | C1 | Manufacture | Ingersol Rand | Atlas Copco |
7 | C2 | Model | H250W | ZA 315 VSD |
8 | C3 | Full load CFM | 1070 | 2020 |
9 | C4 | Rated pressure, psig | 125 | 125 |
10 | C6 | Compressor nameplate HP | 250 | 394 |
11 | C7 | Compressor nameplate efficiency | 94.1% | 95.8% |
12 | C8 | Fan nameplate HP | 0 | 0 |
13 | C9 | Fan nameplate efficiency | 0.0% | 0.0% |
14 | C10 | Total input kW at 0 flow | 49.0 | 0.0 |
15 | C11 | Total kW at rated flow/pressure | 200.5 | 331.0 |
16 | C12 | Specific Package kW / 100 CFM | 18.7 | 16.4 |
17 | C13 | Control Type | On Line / Off Line | VFD |
18 | C15 | Unload kW as a % of Full Load kW | 24% | 0% |
19 | C16 | Reload pressure set point (low psig) | 105 | 119 |
20 | C17 | Unload pressure set point (high psig) | 115 | 121 |
21 | C18 | Compressor avg. discharge pressure | 110 | 120 |
22 | C21 | Receiver capacity (gallons) | 2900 | 2900 |
23 | C22 | Compressor timeout delay (minutes) | 10 | 0 |
24 | C23 | Cooling Type | Water Cooled | Water Cooled |
25 | ||||
26 | ||||
27 | ||||
28 | ||||
29 | ||||
30 | ||||
31 | ||||
32 | ||||
33 | ||||
34 | ||||
35 | ||||
36 | ||||
37 | ||||
38 | ||||
39 | ||||
40 | ||||
41 | ||||
42 | ||||
43 | ||||
44 | ||||
45 | ||||
46 | ||||
47 | ||||
48 | ||||
49 | ||||
50 | ||||
51 | ||||
52 | ||||
53 | ||||
54 | ||||
55 | ||||
56 | ||||
57 | ||||
58 | ||||
59 | ||||
60 | ||||
61 | ||||
62 | ||||
63 | ||||
64 | ||||
65 | ||||
66 | ||||
67 | ||||
68 | ||||
69 | ||||
70 | ||||
71 | ||||
72 | ||||
73 | ||||
74 | ||||
75 | ||||
76 | ||||
77 | ||||
78 | ||||
79 | ||||
80 | ||||
81 | ||||
82 | ||||
83 | ||||
84 | ||||
85 | ||||
86 | ||||
87 | ||||
88 | ||||
89 | ||||
90 | ||||
91 | ||||
92 | ||||
93 | ||||
94 | ||||
95 | ||||
96 | ||||
97 | ||||
98 | ||||
99 | ||||
100 | ||||