| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | AA | AB | AC | AD | AE | AF | AG | AH | AI | AJ | AK | AL | AM | AN | AO | AP | AQ | AR | AS | AT | AU | AV | AW | AX | AY | AZ | BA | BB | BC | BD | BE | BF | BG | BH | BI | BJ | BK | BL | BM | BN | BO | BP | BQ | BR | BS | BT | BU | BV | BW | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Whole Home Pilot Projects- Last Updated August 2021 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 | THE INFORMATION SET FORTH HEREIN IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. THE INFORMATION IS BEING PROVIDED TO YOU AS OF THE DATE HEREOF AND MAY BE SUBJECT TO CHANGE AND/OR WITHDRAWAL AT ANY TIME WITHOUT NOTICE. THE INFORMATION IS BASED UPON (A) DATA THAT MAY NO LONGER BE CURRENT; AND (B) FACTORS, MODELS, ASSUMPTIONS AND OTHER INFORMATION THAT WERE DETERMINED TO BE RELEVANT AT THE TIME OF THE ISSUANCE OF A SPECIFIC AWARD AND WHICH MAY DIFFER OR NOT BE APPLICABLE TO ALL CURRENT AND FUTURE PROGRAM PARTICIPANTS. THE INFORMATION SET FORTH HEREIN MAY NOT NECESSARILY REFLECT MASSCEC’S INTERNAL BOOKS AND RECORDS WITH RESPECT TO THE AWARD(S) IN QUESTION DUE TO THE ACCOUNTING METHODS, RULES AND PROCEDURES EMPLOYED BY MASSCEC. THE USER MUST ACCEPT SOLE RESPONSIBILITY ASSOCIATED WITH THE USE OF THE INFORMATION FOUND ON THIS DATASITE, IRRESPECTIVE OF THE PURPOSE FOR WHICH SUCH USE OR RESULTS ARE APPLIED. ACCORDINGLY, TO THE FULLEST EXTENT PERMISSIBLE PURSUANT TO APPLICABLE LAW, MASSCEC DISCLAIMS ALL WARRANTIES (WHETHER EXPRESS, STATUTORY OR IMPLIED) OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY OTHER WARRANTY ARISING UNDER APPLICABLE FEDERAL AND STATE LAW. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3 | Rebate Approved by MassCEC | City | Primary Installer Company & Name | Electric Utility | Building Type | Is this project new construction or a gut renovation? | Housing Type | What standard/s is the home being built to meet? | Would a natural gas hook-up have been possible for this home? | If you were not installing air-source heat pumps, what type of heating system would you have installed as the primary heating system? | If you were not installing air-source heat pumps, what type of cooling system would you have installed as the primary cooling system? | Total conditioned square footage of the home (sq ft) | Peak Building Heat Load (BTU/hr) | Estimated year of original home construction | Previous Primary Heating Source | What is the name plate capacity of the previous primary heating system in MBH (thousands of BTU/hr?) | Did the previous primary heating system (e.g., natural gas boiler or furnace) also heat the home's domestic hot water? | Is the previous primary heating system being removed or left in place? | Estimated Age of Previous Primary Heating Source | Estimated Efficiency of Previous Primary Heating Source | Does the home contain any non-fossil fuel supplemental heat source? | Does the home require an electric service upgrade to install the air-source heat pumps? (For example, 100 amps to 200 amps) | What was the previous source of cooling for the home? | Did the home previously use natural gas for any of the following appliances? | Are any of the following natural gas appliances being changed to non-fossil fuel appliances as part of this project? | What type of cooking appliance will be installed in the home? | What type of domestic hot water appliance will be installed in the home? | What type of clothes dryer appliance will be installed in the home? | Type of air-source heat pump | Does the air-to-water heat pump include an electric resistance booster? | Does the air-to-water heat pump provide domestic hot water? | Number of Outdoor Units | Manufacture of Outdoor Unit #1 | Model of Outdoor Unit #1 | AHRI Number of Outdoor Unit #1 | Outdoor Unit #1 Capacity at Design Temperature (btu/hr) | Manufacture of Outdoor Unit #2 | Model of Outdoor Unit #2 | AHRI Number of Outdoor Unit #2 | Outdoor Unit #2 Capacity at Design Temperature (btu/hr) | Manufacture of Outdoor Unit #3 | Model of Outdoor Unit #3 | AHRI Number of Outdoor Unit #3 | Outdoor Unit #3 Capacity at Design Temperature (btu/hr) | Manufacture of Outdoor Unit #4 | Model of Outdoor Unit #4 | AHRI Number of Outdoor Unit #4 | Outdoor Unit #4 Capacity at Design Temperature (btu/hr) | Manufacture of Outdoor Unit #5 | Model of Outdoor Unit #5 | AHRI Number of Outdoor Unit #5 | Outdoor Unit #5 Capacity at Design Temperature (btu/hr) | Manufacture of Outdoor Unit #6 | Model of Outdoor Unit #6 | AHRI Number of Outdoor Unit #6 | Outdoor Unit #6 Capacity at Design Temperature (btu/hr) | Outdoor Unit Type | Indoor Unit Type | Total Capacity of Outdoor Units at Design Temperature (btu/hr) | Percentage of Total Capacity of Outdoor Units to Peak Heating Load | Will the air to water heat pumps also provide domestic hot water? | If yes, is there a backup electric resistance heating system? | Estimated Cost of Heat pump equipment | Estimated Cost of Other parts and equipment | Estimated Cost of Heat pump installation labor | Estimated Cost of Electrician costs | Estimated Cost of Permitting | Estimated Cost of Ductwork costs (if applicable) | Estimated Cost of Removal of previous heating system (if applicable) | Estimated Cost of Tax (if applicable) | Estimated Cost of Other (if applicable) | Total Estimated Installed Project Cost | Are you applying for the Blower Door Test Rebate Adder? | Affordable Access to Clean and Efficient Energy (AACEE) project? (Y /N) | Total Estimated Rebate |
4 | 7/1/2019 | Cambridge | Net Zero Heating & Air Conditioning, LLC - Tyler Fitzgerald | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1548 | 33600 | 1920-1929 | Natural Gas Steam Boiler | 100 | No | The previous primary heating system is being removed | More than 20 years old | 75%-80% | electric radiant floor heating for the bathroom | No | None | Stove/oven; Domestic Hot Water | No | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-5C42NAHZ | 201754926 | 45000 | Multi-head minisplit | Ductless | 45000 | 133.93 | $8,893.12 | $2,332.50 | $5,280.00 | $715.00 | $40.00 | $0.00 | $0.00 | $697.85 | $0.00 | $17,958.47 | No | $2,500 | |||||||||||||||||||||||||
5 | 7/8/2019 | Newburyport | Affinity Heating & A/C - Michael Sheppard | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2110 | 49663 | Before 1900 | Natural Gas Furnace | 139 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | Less than 5 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | NONE | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 3 | Mitsubishi | MXZ-3C24NAHZ2 | 201754904 | 24000 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 20000 | MXZ-2C20NAHZ2 | MXZ-2C20NAHZ2 | 202732309 | 20000 | Multi-head minisplit | Ductless | 64000 | 128.87 | $11,800.00 | $2,000.00 | $7,600.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $21,400.00 | No | $2,500 | |||||||||||||||||
6 | 11/5/2019 | West Newton | Keyes North Atlantic, Inc. - Nick Consilvio | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2793 | 37881 | 1930-1939 | Natural Gas Furnace | 107 | No | The previous primary heating system is being removed | 15-20 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water; Clothes Dryer | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 4 | Mitsubishi | MUZ-FH06NAH | 201754426 | 8700 | Mitsubishi | MUFZ-KJ09NAHZ | 201754416 | 11000 | MUFZ-KJ09NAHZ | MUFZ-KJ09NAHZ | 201754416 | 11000 | Mitsubishi | SUZ-KA12NA2 | 202392053 | 7800 | Single-head mini-split | Mix of ducted and ductless | 38500 | 101.63 | $9,477.67 | $2,942.11 | $3,795.00 | $7,143.01 | $190.00 | $14,658.42 | $1,495.00 | $0.00 | $8,855.00 | $48,556.21 | No | $2,500 | |||||||||||||
7 | 6/24/2019 | Boston | Divison 15-N/A N/A | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1296 | 38799 | 1930-1939 | Natural Gas Steam Boiler | 112 | No | The previous primary heating system is being left in place, but turned off or disabled | 10-15 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Domestic Hot Water | N/A | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi Electric | MXZ-4C36NAHZ | 201755020 | 42444 | Multi-head minisplit | Mix of ducted and ductless | 42444 | 109.39 | $6,500.00 | $1,000.00 | $6,000.00 | $1,000.00 | $0.00 | $500.00 | $0.00 | $0.00 | $0.00 | $15,000.00 | No | $2,500 | |||||||||||||||||||||||||
8 | 8/13/2019 | Woburn | Net Zero Heating & Air Conditioning, LLC - Tyler Fitzgerald | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1052 | 26947 | 1940-1949 | Natural Gas Hot Water Boiler | 72 | No | The previous primary heating system is being left in place and operational | Less than 5 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | None | Stove/oven; Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Carrier | 38MGRQ24C--3 | 9854622 | 24170 | Carrier | 38MGRQ18B-3 | 9118461 | 13990 | Multi-head minisplit | Ductless | 38160 | 141.61 | $6,471.77 | $1,563.73 | $4,640.00 | $715.00 | $100.00 | $0.00 | $0.00 | $501.98 | $0.00 | $13,992.48 | Yes | $3,750 | |||||||||||||||||||||
9 | 7/25/2019 | Northampton | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Propane | Central AC System | 1188 | 12458 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MUZ-FH12NAH | 201754299 | 13600 | Single-head mini-split | Ductless | 13600 | 109.17 | $2,050.00 | $1,300.00 | $1,600.00 | $750.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $5,750.00 | Yes | $5,000 | |||||||||||||||||||||||||
10 | 8/1/2019 | Northampton | Gates HVACR LLC - John Gates | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1925 | 41154 | 1900-1909 | Natural Gas Steam Boiler | 151000 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU36RLXFZH | 8908615 | 32000 | Fujitsu | AOU18RLXFZH | 8033584 | 17200 | Multi-head minisplit | Ductless | 49200 | 119.55 | $11,500.00 | $2,500.00 | $10,000.00 | $1,800.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $25,800.00 | No | $2,500 | |||||||||||||||||||||
11 | 10/15/2019 | Arlington | Energy Monster - Nicholas Giacobbi | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1700 | 41239.13 | 1960-1969 | Natural Gas Hot Water Boiler | 155 | No | The previous primary heating system is being left in place and operational | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s); Ceiling Fan; Window Fan | Stove/oven; Domestic Hot Water; Clothes Dryer | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-5C42NAHZ-U1 | 201754926 | 46500 | Multi-head minisplit | Ductless | 46500 | 112.76 | $4,693.80 | $1,802.04 | $14,151.98 | $450.00 | $200.00 | $0.00 | $0.00 | $1,331.18 | $0.00 | $22,629.00 | No | $2,500 | |||||||||||||||||||||||||
12 | 9/30/2019 | Auburn | Chaves Heating and Air Conditioning, Inc. - Andre Chaves | National Grid | New construction (including gut rehab) | Gut renovation | Single-family (detached) | Massachusetts Stretch Code | No | Oil | Central AC System | 2044 | 34502 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Supplemental electric resistance heat; Pellet stove | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-4C36NAHZ | 201754912 | 42000 | Multi-head minisplit | Ductless | 42000 | 121.73 | $5,201.48 | $2,159.19 | $4,209.86 | $1,000.00 | $100.00 | $0.00 | $0.00 | $0.00 | $800.33 | $13,470.86 | Yes | $5,000 | |||||||||||||||||||||||||
13 | 8/13/2019 | Northampton | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Propane | Central AC System | 1188 | 12458 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home; n/a | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater; n/a | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MUZ-FH12NAH | 201754299 | 13600 | Single-head mini-split | Ductless | 13600 | 109.17 | $2,050.00 | $1,300.00 | $1,600.00 | $750.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $5,750.00 | Yes | $5,000 | |||||||||||||||||||||||||
14 | 8/16/2019 | Northamtpon | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Propane | Central AC System | 1188 | 12458 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MUZ-FH12NAH | 201754299 | 13600 | Single-head mini-split | Ductless | 13600 | 109.17 | $2,050.00 | $1,300.00 | $1,600.00 | $750.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $5,750.00 | Yes | $5,000 | |||||||||||||||||||||||||
15 | 8/22/2019 | FLORENCE | Climates by Pomeroy - Samuel J. Pomeroy | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 3198 | 23103 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home; Supplemental electric resistance heat | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 3 | FUJITSU | AOU9RLS3 | 8703348 | 15000 | FUJITSU | AOU9RLS3 | 8703348 | 15000 | AOU9RLS3 | AOU9RLS3 | 8703348 | 15000 | Single-head mini-split | Ductless | 45000 | 194.78 | $8,000.00 | $1,000.00 | $3,000.00 | $1,500.00 | $0.00 | $0.00 | $0.00 | $0.00 | $500.00 | $14,000.00 | Yes | $5,000 | |||||||||||||||||
16 | 8/13/2019 | Watertown | Net Zero Heating & Air Conditioning, LLC - Steve Smith | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1891 | 43753 | 1910-1919 | Natural Gas Hot Water Boiler | 100 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being removed | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | Yes | None | None | Stove/oven; Domestic Hot Water; Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Carrier | 25VNA024A030 | 9892513 | 19800 | Carrier | 25VNA024A030 | 9892513 | 19800 | Centrally Ducted | Ducted | 39600 | 90.51 | $18,432.26 | $1,860.36 | $6,960.00 | $0.00 | $250.00 | $3,028.13 | $0.00 | $1,365.93 | $0.00 | $31,896.68 | No | $2,500 | |||||||||||||||||||||
17 | 8/13/2019 | Cambridge | Keyes North Atlantic, Inc. - Nick Consilvio | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2128 | 39050 | Before 1900 | Natural Gas Hot Water Boiler | 108 | No | The previous primary heating system is being removed | 10-15 years old | Unknown | Supplemental electric resistance heat | Yes | Window Unit(s); Ceiling Fan | Stove/oven; Domestic Hot Water | Stove/oven; Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Carrier | 25VNA048A030 | 9892751 | 38070 | Centrally Ducted | Ducted | 38070 | 97.49 | $3,000.00 | $2,400.00 | $25,195.00 | $0.00 | $0.00 | $5,905.00 | $0.00 | $0.00 | $0.00 | $36,500.00 | No | $2,500 | |||||||||||||||||||||||||
18 | 8/13/2019 | Cambridge | Keyes North Atlantic, Inc. - Nick Consilvio | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1177 | 26201 | Before 1900 | Natural Gas Hot Water Boiler | 191 | No | The previous primary heating system is being removed | 5-10 years old | Unknown | Supplemental electric resistance heat | Yes | Window Unit(s); Ceiling Fan | Stove/oven; Domestic Hot Water | Stove/oven; Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-5C42NAHZ | 201754926 | 48000 | Multi-head minisplit | Ductless | 48000 | 183.2 | $6,640.00 | $1,400.00 | $16,260.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $24,300.00 | No | $2,500 | |||||||||||||||||||||||||
19 | 9/24/2019 | Northampton | Gates HVACR LLC - John Gates | National Grid | Existing building | N/A - Existing Building | 8 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1635 | 40947 | 1920-1929 | Natural Gas Furnace | 75 | No | The previous primary heating system is being removed | 15-20 years old | 75%-80% | Supplemental electric resistance heat | No | Ceiling Fan | Domestic Hot Water | No | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (VRF) | 1 | Fujitsu | AOU48RLAVM | 8693477 | 41300 | VRF | Mix of ducted and ductless | 41300 | 100.86 | $10,500.00 | $3,500.00 | $10,000.00 | $2,000.00 | $0.00 | $0.00 | $800.00 | $0.00 | $0.00 | $26,800.00 | No | $2,500 | |||||||||||||||||||||||||
20 | 9/30/2019 | Somerville | Mass Mini-Splits - Ryan Farnham | Eversource | New construction (including gut rehab) | New construction | 4 unit | Massachusetts Base Code; Massachusetts Stretch Code | Yes | Natural gas | Central AC System | 1325 | 16740 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Mix of ducted and ductless | 28600 | 170.85 | $7,000.00 | $0.00 | $6,000.00 | $0.00 | $600.00 | $2,400.00 | $0.00 | $0.00 | $0.00 | $16,000.00 | No | $2,500 | |||||||||||||||||||||||||
21 | 9/30/2019 | Somerville | Mass Mini-Splits - Ryan Farnham | Eversource | New construction (including gut rehab) | New construction | 4 unit | Massachusetts Base Code; Massachusetts Stretch Code | Yes | Natural gas | Central AC System | 1568 | 20126 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home; none | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-2C20NAHZ2-U1 | 201755014 | 22000 | Multi-head minisplit | Mix of ducted and ductless | 22000 | 109.31 | $6,500.00 | $0.00 | $6,500.00 | $0.00 | $600.00 | $2,400.00 | $0.00 | $0.00 | $0.00 | $16,000.00 | No | $2,500 | |||||||||||||||||||||||||
22 | 9/30/2019 | Somerville | Mass Mini-Splits - Ryan Farnham | Eversource | New construction (including gut rehab) | New construction | 4 unit | Massachusetts Base Code; Massachusetts Stretch Code; none | Yes | Natural gas | Central AC System | 1543 | 19689 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Mix of ducted and ductless | 28600 | 145.26 | $6,500.00 | $0.00 | $6,500.00 | $0.00 | $600.00 | $2,400.00 | $0.00 | $0.00 | $0.00 | $16,000.00 | No | $2,500 | |||||||||||||||||||||||||
23 | 9/30/2019 | Somerville | Mass Mini-Splits - Ryan Farnham | Eversource | New construction (including gut rehab) | New construction | 4 unit | Massachusetts Base Code; Massachusetts Stretch Code | Yes | Natural gas | Central AC System | 1551 | 19408 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-2C20NAHZ2-U1 | 201755014 | 22000 | Multi-head minisplit | Mix of ducted and ductless | 22000 | 113.36 | $6,500.00 | $0.00 | $6,500.00 | $0.00 | $600.00 | $2,400.00 | $0.00 | $0.00 | $0.00 | $16,000.00 | No | $2,500 | |||||||||||||||||||||||||
24 | 9/13/2019 | Somerville | Energy Monster - Nicholas Giacobbi | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 755 | 20371 | 1920-1929 | Natural Gas Furnace | 100 | No | The previous primary heating system is being left in place and operational | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2-U1 | 201754904 | 25000 | Multi-head minisplit | Ductless | 25000 | 122.72 | $2,959.80 | $526.61 | $9,366.77 | $500.00 | $100.00 | $0.00 | $0.00 | $840.82 | $0.00 | $14,294.00 | No | $2,500 | |||||||||||||||||||||||||
25 | 10/15/2019 | Greenfield | M.J. Moran, Inc. - Scott Cernak | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2032 | 41241 | 1920-1929 | Natural Gas Steam Boiler | 125 | No | The previous primary heating system is being removed | More than 20 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home | Yes | Window Unit(s) | Stove/oven; Domestic Hot Water | Stove/oven; Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-5C42NAHZ | 201754926 | 40468 | Multi-head minisplit | Ductless | 40468 | 98.13 | $8,120.00 | $1,146.00 | $2,600.00 | $0.00 | $0.00 | $0.00 | $1,250.00 | $580.00 | $0.00 | $13,696.00 | No | $2,500 | |||||||||||||||||||||||||
26 | 11/19/2019 | Arlington | New England Ductless - Joseph Wood | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 928 | 26843 | 1940-1949 | Natural Gas Hot Water Boiler | 109 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place, but turned off or disabled | More than 20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Existing Heat Pumps | Stove/oven; Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Ductless | 28600 | 106.55 | $3,990.00 | $0.00 | $7,000.00 | $1,150.00 | $200.00 | $0.00 | $0.00 | $0.00 | -$355.00 | $11,985.00 | No | $2,500 | |||||||||||||||||||||||||
27 | 10/18/2019 | Amherst | M.J. Moran, Inc. - Scott Cernak | Eversource | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Base Code; HERS Rating Target (describe below) | No | Propane | Central AC System | 2219 | 35508 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Induction cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 4 | Mitsubishi | MUZ-FH18NA2 | 201754302 | 20300 | Mitsubishi | MUZ-FH09NA | 201754296 | 10900 | MUZ-FH06NA | MUZ-FH06NA | 201754427 | 8700 | Mitsubishi | MUZ-FH06NA | 201754427 | 8700 | Single-head mini-split | Ductless | 48600 | 136.87 | $9,150.00 | $1,668.00 | $4,000.00 | $2,000.00 | $0.00 | $0.00 | $0.00 | $572.00 | $0.00 | $17,390.00 | No | $2,500 | |||||||||||||
28 | 11/12/2019 | East Orleans | Eric Meads Inc. - Eric Meads | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1200 | 30605 | 1950-1959 | Natural Gas Furnace | 133 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place, but turned off or disabled | 15-20 years old | Unknown | No, the air-source heat pumps are the only source of space heating in the home | No | Window Fan | Stove/oven; Domestic Hot Water | No | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU24RLXFZH | 8033586 | 25500 | Fujitsu | AOU18RLXFZH | 8033584 | 22000 | Multi-head minisplit | Ductless | 47500 | 155.2 | $6,552.19 | $2,954.87 | $4,000.00 | $1,201.30 | $0.00 | $0.00 | $0.00 | $592.94 | $0.00 | $15,301.30 | Yes | $5,000 | |||||||||||||||||||||
29 | 10/29/2019 | bedford | Unique Indoor Comfort - Steve Martin | Eversource | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 3000 | 38406 | 1980-1989 | Natural Gas Furnace | 80 | No | The previous primary heating system is being removed | 10-15 years old | 90%-95% | Supplemental electric resistance heat | No | Central AC System | Stove/oven; Domestic Hot Water | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Bosch | Bova-60HDN1-M20G | 202868497 | 40000 | Centrally Ducted | Ducted | 40000 | 104.15 | $10,250.00 | $1,296.00 | $3,600.00 | $1,000.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $16,146.00 | No | $2,500 | |||||||||||||||||||||||||
30 | 11/20/2019 | Medford | Excel Mechanical, Inc. - Bill Souza | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 3080 | 32781 | 1920-1929 | Other | 144 | Yes, through a tankless coil | The previous primary heating system is being removed | 5-10 years old | 80%-85% | Supplemental electric resistance heat | No | Window Unit(s); Ceiling Fan; Window Fan | N/A - no natural gas connection | N/A - no natural gas connection | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-water | Yes | No | 1 | SpacePak | LAHP48 | LAHP48 | 41000 | Air to Water | Hydronic | 41000 | 125.07 | No | $17,000.00 | $4,955.65 | $14,600.00 | $4,000.00 | $0.00 | $0.00 | $2,080.00 | $0.00 | $0.00 | $42,635.65 | No | $2,500 | ||||||||||||||||||||||
31 | 2/20/2020 | Methuen | Coastal Mechanical, LLC - Richard Nimmo | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1271 | 38948 | 1930-1939 | Natural Gas Furnace | 60 | No | The previous primary heating system is being removed | More than 20 years old | Unknown | Supplemental electric resistance heat | Yes | None | Stove/oven; Domestic Hot Water; Clothes Dryer | Stove/oven; Domestic Hot Water; Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU24RLXFZH | 8033586 | 25000 | Fujitsu | AOU24RLXFZH | 8033586 | 25000 | Multi-head minisplit | Ductless | 50000 | 128.38 | $16,000.00 | $1,000.00 | $4,500.00 | $2,500.00 | $500.00 | $1,500.00 | $0.00 | $0.00 | $0.00 | $26,000.00 | Yes | $5,000 | |||||||||||||||||||||
32 | 1/16/2020 | Salem | Ace Energy Services, Inc. - Dan Jarmolowicz | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | Massachusetts Stretch Code; HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1139 | 20496 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ3C24NAHZ2-U1 | 201754904 | 25000 | Multi-head minisplit | Ductless | 25000 | 121.98 | $4,000.00 | $1,400.00 | $4,800.00 | $500.00 | $300.00 | $0.00 | $0.00 | $400.00 | $0.00 | $11,400.00 | No | $2,500 | |||||||||||||||||||||||||
33 | 1/16/2020 | Salem | Ace Energy Services, Inc. - Dan Jarmolowicz | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | Massachusetts Base Code; Massachusetts Stretch Code; HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1093 | 19841 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ2C20NAHZ2-U1 | 202732309 | 22000 | Multi-head minisplit | Ductless | 22000 | 110.88 | $3,000.00 | $600.00 | $2,400.00 | $400.00 | $300.00 | $0.00 | $0.00 | $400.00 | $0.00 | $7,100.00 | No | $2,500 | |||||||||||||||||||||||||
34 | 7/10/2020 | Winchester | New England Ductless - Joseph Wood | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1896 | 42561 | 1920-1929 | Natural Gas Steam Boiler | 90 | No | The previous primary heating system is being left in place and operational | 15-20 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home; Supplemental electric resistance heat | No | Window Unit(s); Window Fan | Domestic Hot Water | Steam Boiler | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-3C24NAHZ | 201754904 | 25000 | Mitsubishi | MXZ-4C36NAHZ2 | 201755020 | 45000 | Multi-head minisplit | Ductless | 70000 | 164.47 | $13,131.00 | $2,900.00 | $7,500.00 | $1,900.00 | $300.00 | $9,750.00 | $0.00 | $0.00 | $2,275.00 | $37,756.00 | No | $2,500 | |||||||||||||||||||||
35 | 1/27/2020 | Medford | Net Zero Heating & Air Conditioning, LLC - Tyler Fitzgerald | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1449 | 32581 | 1940-1949 | Natural Gas Hot Water Boiler | 140 | Yes, through a tankless coil | The previous primary heating system is being left in place and operational | Less than 5 years old | Greater than 95% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | PUZ-HA36NHA5 | 201754323 | 38000 | Centrally Ducted | Ducted | 38000 | 116.63 | $8,052.82 | $231.89 | $2,320.00 | $495.00 | $0.00 | $796.88 | $0.00 | $561.35 | $0.00 | $12,457.94 | Yes | $5,000 | |||||||||||||||||||||||||
36 | 1/27/2020 | Arlington | Aldo's HVAC LLC - Adroaldo Vieira | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 4589 | 74162 | Before 1900 | Natural Gas Furnace | 117 | No | The previous primary heating system is being left in place, but turned off or disabled | 5-10 years old | Unknown | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water; Clothes Dryer | Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Bosch | BOVA-60HDN1-M20G | 203377015 | 42800 | ECOER | EODA18H-4860 | 202110530 | 36000 | Centrally Ducted | Ducted | 78800 | 106.25 | $13,680.00 | $1,500.00 | $8,000.00 | $1,000.00 | $500.00 | $4,000.00 | $0.00 | $0.00 | $0.00 | $28,680.00 | No | $2,500 | |||||||||||||||||||||
37 | 2/27/2020 | Holyoke | Energy Monster - Nicholas Giacobbi | Holyoke MLP | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2775 | 45568 | 1900-1909 | Natural Gas Steam Boiler | 105 | No | The previous primary heating system is being left in place and operational | 10-15 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | Yes | Window Unit(s) | Domestic Hot Water | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 22000 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 22000 | Multi-head minisplit | Ductless | 44000 | 96.56 | $5,565.60 | $888.98 | $11,930.36 | $3,450.00 | $0.00 | $0.00 | $0.00 | $1,149.06 | $0.00 | $22,984.00 | Yes | $5,000 | |||||||||||||||||||||
38 | 2/24/2020 | Woburn | Net Zero Heating & Air Conditioning, LLC - Tyler Fitzgerald | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1649 | 55803 | 1940-1949 | Natural Gas Steam Boiler | 145 | No | The previous primary heating system is being removed | More than 20 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home | Yes | None | Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MCX-4C36NAHZ | 201755020 | 45000 | Mitsubishi | MXZ-3C24NAHZ | 201754904 | 25000 | Multi-head minisplit | Mix of ducted and ductless | 70000 | 125.44 | $14,973.60 | $1,061.03 | $6,960.00 | $935.00 | $0.00 | $1,925.25 | $0.00 | $1,094.36 | $0.00 | $26,949.24 | No | $2,500 | |||||||||||||||||||||
39 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
40 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
41 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
42 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
43 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
44 | 2/20/2020 | Vineyard Haven | Nelson Mechanical Design, Inc. - David Sprague | Eversource | New construction (including gut rehab) | New construction | 2 unit | Massachusetts Stretch Code; Energy Star Certified Home | No | Propane | Central AC System | 1152 | 18193 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 24800 | 136.32 | $6,771.46 | $805.52 | $10,280.00 | $0.00 | $0.00 | $907.78 | $0.00 | $0.00 | $0.00 | $18,764.76 | Yes | $5,000 | |||||||||||||||||||||||||
45 | 3/18/2020 | Framingham | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 3791 | 46754 | 1960-1969 | Natural Gas Hot Water Boiler | 164 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 15-20 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Bosch | Bova-36WN1-M20 | 202868496 | 23000 | Bosch | Bova-36WN1-M20 | 202868496 | 23000 | Centrally Ducted | Ducted | 46000 | 98.39 | $18,500.00 | $6,290.00 | $7,998.00 | $3,500.00 | $0.00 | $1,000.00 | $500.00 | $0.00 | $2,185.00 | $39,973.00 | No | $2,500 | |||||||||||||||||||||
46 | 2/27/2020 | Boston | BDL Heating and Cooling Inc. - Steve Worthington | Eversource | Existing building | N/A - Existing Building | 5 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 675 | 16849 | 1910-1919 | Other | 23 | No | The previous primary heating system is being left in place and operational | Unknown | Less than 50% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | None | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | MITSUBISHI | MUZ-FH15NA | 201754300 | 18000 | Single-head mini-split | Ductless | 18000 | 106.83 | $2,420.00 | $620.00 | $2,500.00 | $1,080.00 | $250.00 | $0.00 | $0.00 | $0.00 | $1,800.00 | $8,670.00 | No | $2,500 | |||||||||||||||||||||||||
47 | 6/22/2020 | Cambridge | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 770 | 23198 | 1920-1929 | Natural Gas Steam Boiler | 210 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Domestic Hot Water | heating system | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C24NAHZ2 | 201754904 | 25000 | Multi-head minisplit | Ductless | 25000 | 107.77 | $8,500.00 | $1,200.00 | $4,798.00 | $1,500.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $15,998.00 | No | $2,500 | |||||||||||||||||||||||||
48 | 3/18/2020 | Boston | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1696 | 44568 | 1920-1929 | Natural Gas Hot Water Boiler | 108 | No | The previous primary heating system is being left in place and operational | 10-15 years old | 75%-80% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU24RGLX | 202537547 | 22220 | Fujitsu | AOU24RGLX | 202537547 | 22220 | Centrally Ducted | Ducted | 44440 | 99.71 | $13,000.00 | $1,419.00 | $5,000.00 | $3,000.00 | $0.00 | $12,000.00 | $0.00 | $0.00 | $0.00 | $34,419.00 | No | $2,500 | |||||||||||||||||||||
49 | 4/8/2020 | Winthrop | New England Ductless - Joseph Wood | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | Massachusetts Base Code | Yes | Natural gas | None | 952 | 18657 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - Tankless | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU240HHV | 10445374 | 26000 | Multi-head minisplit | Ductless | 26000 | 139.36 | $7,400.00 | $312.00 | $3,500.00 | $900.00 | $250.00 | $0.00 | $0.00 | $51.52 | $0.00 | $12,413.52 | No | $2,500 | |||||||||||||||||||||||||
50 | 4/8/2020 | Winthrop | New England Ductless - Joseph Wood | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | Massachusetts Base Code | Yes | Natural gas | None | 952 | 18791 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU240HHV | 10445374 | 26000 | Multi-head minisplit | Ductless | 26000 | 138.36 | $7,460.00 | $242.00 | $3,500.00 | $900.00 | $250.00 | $0.00 | $0.00 | $61.52 | $0.00 | $12,413.52 | No | $2,500 | |||||||||||||||||||||||||
51 | 6/1/2020 | South Boston | A. Moschella Refrigeration LLC - Anthony Moschella | Eversource | Existing building | N/A - Existing Building | 6 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 844 | 26996 | 1980-1989 | Natural Gas Hot Water Boiler | 60 | No | The previous primary heating system is being left in place, but turned off or disabled | More than 20 years old | Unknown | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Domestic Hot Water | N/A | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ | 201754908 | 28600 | Centrally Ducted | Ducted | 28600 | 105.94 | $5,750.00 | $0.00 | $6,600.00 | $1,000.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $13,350.00 | No | $2,500 | |||||||||||||||||||||||||
52 | 7/28/2020 | Somerville | Custom Air Systems - Matthew Gleason | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2164 | 24953 | 1910-1919 | Natural Gas Steam Boiler | 86 | No | The previous primary heating system is being removed | More than 20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | Yes | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU36RLXFZH | 8908615 | 36407 | Fujitsu | AOU12RLFFH | 6937310 | 15000 | Multi-head minisplit | Ductless | 51407 | 206.02 | $8,052.00 | $250.00 | $9,748.00 | $1,700.00 | $75.00 | $0.00 | $1,000.00 | $0.00 | $0.00 | $20,825.00 | Yes | $5,000 | |||||||||||||||||||||
53 | 6/1/2020 | Medford | Siggy's Plumbing and Heating - Steven Segreve | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1920 | 33297 | 1910-1919 | Natural Gas Hot Water Boiler | 80 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 5-10 years old | 90%-95% | Wood stove | Yes | Window Unit(s) | Stove/oven; Clothes Dryer | Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-8C48NAHZ2 | 204834268 | 54000 | Centrally Ducted | Ducted | 54000 | 162.18 | $13,350.00 | $4,675.00 | $6,585.00 | $0.00 | $0.00 | $6,190.00 | $0.00 | $0.00 | $1,300.00 | $32,100.00 | No | $2,500 | |||||||||||||||||||||||||
54 | 4/14/2020 | Florence | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Propane | Central AC System | 936 | 12681 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | MUZ-FH12NA | 201754298 | 13600 | Single-head mini-split | Ductless | 13600 | 107.25 | $2,400.00 | $1,200.00 | $850.00 | $750.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $5,250.00 | Yes | $5,000 | |||||||||||||||||||||||||
55 | 4/14/2020 | Shutesbury | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Propane | Central AC System | 1344 | 17887 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Electric - with Tank | Standard Electric Clothes Dryer | Air-to-air (Standard) | 2 | Mitsubishi | MUZ-FH09NA | 201754296 | 10900 | Mitsubishi | MUZ-GL12NA | 202680595 | 10200 | Single-head mini-split | Ductless | 21100 | 117.96 | $3,450.00 | $750.00 | $1,950.00 | $1,000.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $7,200.00 | Yes | $7,500 | |||||||||||||||||||||
56 | 4/13/2020 | Amherst | M.J. Moran, Inc. - Scott Cernak | Eversource | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Stretch Code | No | Propane | Central AC System | 2646 | 40333 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 5 | Mitsubishi | MUZ-FH09NA | 201754296 | 10900 | Mitsubishi | MUZ-FH12NA | 201754298 | 13600 | MUZ-FH06NA | MUZ-FH06NA | 201754426 | 8700 | Mitsubishi | MUZ-FH06NA | 201754426 | 8700 | Mitsubishi | 0 | 201754416 | 11000 | Single-head mini-split | Ductless | 52900 | 131.16 | $9,886.00 | $2,844.00 | $5,800.00 | $0.00 | $50.00 | $0.00 | $0.00 | $798.00 | $0.00 | $19,378.00 | No | $2,500 | |||||||||
57 | 4/13/2020 | Amherst | M.J. Moran, Inc. - Scott Cernak | Eversource | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Stretch Code | No | Propane | Central AC System | 2277 | 34222 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 4 | Mitsubishi | MUZ-FH09NA | 201754296 | 10900 | Mitsubishi | MUZ-FH12NA | 201754298 | 13600 | MUZ-FH06NA | MUZ-FH06NA | 201754426 | 8700 | Mitsubishi | MUZ-FH06NA | 201754426 | 8700 | Single-head mini-split | Ductless | 41900 | 122.44 | $7,830.00 | $2,286.00 | $4,780.00 | $0.00 | $50.00 | $0.00 | $0.00 | $632.00 | $0.00 | $15,578.00 | No | $2,500 | |||||||||||||
58 | 5/21/2020 | Billerica | Net Zero Heating & Air Conditioning, LLC - Steve Smith | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Base Code | Yes | Natural gas | Central AC System | 1856 | 21300 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Induction cooktop - Electric Oven | Supplied by existing house | Heat Pump Clothes Dryer | Air-to-air (Standard) | 1 | Mitsubishi | PUZ-A24NHA7 | 201754463 | 14500 | Centrally Ducted | Ducted | 14500 | 68.08 | $4,986.43 | $1,232.76 | $4,640.00 | $0.00 | $0.00 | $2,629.69 | $0.00 | $0.00 | $0.00 | $13,488.88 | No | $2,500 | |||||||||||||||||||||||||
59 | 6/1/2020 | Bourne | Cape Cod Heat Pumps - Jared Grier | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 527 | 14403 | 1940-1949 | Natural Gas Furnace | 40 | No | The previous primary heating system is being removed | 5-10 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | NONE | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RLXFZH | 8033586 | 25000 | Multi-head minisplit | Ductless | 25000 | 173.57 | $3,137.00 | $734.35 | $3,199.69 | $650.00 | $0.00 | $0.00 | $0.00 | $241.96 | $0.00 | $7,963.00 | No | $2,500 | |||||||||||||||||||||||||
60 | 5/14/2020 | Haydenville | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | HERS Rating Target (describe below) | No | Propane | None | 1153 | 27979 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 4 | Mitsubishi | MUZ-FH09NA | 201754296 | 10900 | Mitsubishi | MUZ-FH06NA | 201754426 | 8700 | MUZ-FH06NA | MUZ-FH06NA | 201754426 | 8700 | Mitsubishi | MUZ-FH06NA | 201754426 | 8700 | Single-head mini-split | Ductless | 37000 | 132.24 | $6,560.00 | $730.00 | $8,140.00 | $600.00 | $0.00 | $0.00 | $0.00 | $455.00 | $0.00 | $16,485.00 | No | $2,500 | |||||||||||||
61 | 5/14/2020 | Haydenville | M.J. Moran, Inc. - Scott Cernak | National Grid | New construction (including gut rehab) | Gut renovation | 2 unit | HERS Rating Target (describe below) | No | Propane | None | 1092 | 29651 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 3 | Mitsubishi | MUZ-FH12NA | 201754298 | 13600 | Mitsubishi | MUZ-FH06NA | 201754426 | 8700 | MUZ-FH09NA | MUZ-FH09NA | 201754296 | 10900 | Single-head mini-split | Ductless | 33200 | 111.97 | $7,505.00 | $250.00 | $4,080.00 | $600.00 | $0.00 | $0.00 | $0.00 | $485.00 | $0.00 | $12,920.00 | No | $2,500 | |||||||||||||||||
62 | 6/12/2020 | Brighton | McDonald HVAC Inc - Aaron McDonald | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1511 | 27778 | 1920-1929 | Natural Gas Steam Boiler | 140 | No | The previous primary heating system is being left in place, but turned off or disabled | 15-20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 22000 | Mitsubishi | MXZ-3C24NAHZ2 | 201754904 | 25000 | Multi-head minisplit | Ductless | 47000 | 169.2 | $8,486.56 | $4,800.00 | $5,000.00 | $1,100.00 | $150.00 | $0.00 | $0.00 | $663.44 | $0.00 | $20,200.00 | No | $2,500 | |||||||||||||||||||||
63 | 6/1/2020 | Somerville | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1754 | 33183 | 1920-1929 | Natural Gas Steam Boiler | 115 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Carrier | 25VNA036 | 9892659 | 25252 | Fujitsu | AOU9RLFFH | 6937309 | 14000 | Mixed of single- and multi-head minisplits | Mix of ducted and ductless | 39252 | 118.29 | $11,706.00 | $7,096.00 | $6,444.00 | $3,000.00 | $0.00 | $8,550.00 | $0.00 | $0.00 | $0.00 | $36,796.00 | No | $2,500 | |||||||||||||||||||||
64 | 6/1/2020 | Somerville | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 822 | 34749 | 1920-1929 | Natural Gas Steam Boiler | 100 | No | The previous primary heating system is being left in place and operational | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU36RLXFZH | 8908615 | 36407 | Multi-head minisplit | Ductless | 36407 | 104.77 | $9,296.00 | $2,852.00 | $3,900.00 | $2,950.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $18,998.00 | No | $2,500 | |||||||||||||||||||||||||
65 | 6/1/2020 | Mashpee | Balanced HVAC, Inc. - Lincoln Stubbs | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1118 | 25624 | 1990-1999 | Natural Gas Hot Water Boiler | 120 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Ceiling Fan; Window Fan | Stove/oven | n/a | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Ductless | 28600 | 111.61 | $7,000.00 | $1,000.00 | $2,000.00 | $750.00 | $50.00 | $0.00 | $0.00 | $0.00 | $0.00 | $10,800.00 | No | $2,500 | |||||||||||||||||||||||||
66 | 6/12/2020 | Watertown | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1402 | 34903 | 1940-1949 | Natural Gas Hot Water Boiler | 62 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU36RLXFZH | 8912450 | 36407 | Mixed of single- and multi-head minisplits | Mix of ducted and ductless | 36407 | 104.31 | $8,580.00 | $8,243.00 | $5,000.00 | $2,500.00 | $0.00 | $4,275.00 | $2,000.00 | $0.00 | $400.00 | $30,998.00 | No | $2,500 | |||||||||||||||||||||||||
67 | 6/26/2020 | Salem | Pure Air LLC - Julin Meta | National Grid | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1545 | 42311 | Before 1900 | Natural Gas Furnace | 80 | No | The previous primary heating system is being left in place and operational | 5-10 years old | Greater than 95% | No, the air-source heat pumps are the only source of space heating in the home | Yes | None | Domestic Hot Water | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Bosch | BOVA-60HDN1-M20G | 202868497 | 40000 | Centrally Ducted | Ducted | 40000 | 94.54 | $4,000.00 | $1,000.00 | $1,900.00 | $800.00 | $0.00 | $5,000.00 | $0.00 | $0.00 | $0.00 | $12,700.00 | Yes | $7,500 | |||||||||||||||||||||||||
68 | 6/22/2020 | Orleans | Ivy's Heating and Cooling - Jason Amato | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1360 | 27189.4 | 1970-1979 | Natural Gas Hot Water Boiler | 83 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 5-10 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RLXFZH | 8033586 | 25500 | Single-head mini-split | Ductless | 25500 | 93.79 | $5,662.59 | $0.00 | $2,280.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $7,942.59 | Yes | $7,500 | |||||||||||||||||||||||||
69 | 6/22/2020 | Roslindale | Airco Home Comfort Services, LLC - James Carnevale | National Grid | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 958 | 23408 | 1920-1929 | Natural Gas Steam Boiler | 150 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RGLX | 202537547 | 22220 | Centrally Ducted | Ducted | 22220 | 94.92 | $8,000.00 | $394.00 | $1,500.00 | $1,500.00 | $0.00 | $6,000.00 | $0.00 | $0.00 | $0.00 | $17,394.00 | No | $2,500 | |||||||||||||||||||||||||
70 | 6/22/2020 | Roslindale | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 958 | 21533 | 1920-1929 | Natural Gas Steam Boiler | 150 | No | The previous primary heating system is being removed | More than 20 years old | 50%-75% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RGLX | 202537547 | 22220 | Centrally Ducted | Ducted | 22220 | 103.19 | $8,000.00 | $394.00 | $1,500.00 | $1,500.00 | $0.00 | $6,000.00 | $0.00 | $0.00 | $0.00 | $17,394.00 | No | $2,500 | |||||||||||||||||||||||||
71 | 6/22/2020 | Brookline | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 643 | 16690 | 1920-1929 | Natural Gas Furnace | 60 | No | The previous primary heating system is being left in place and operational | 10-15 years old | 85%-90% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU18RGLX | 202534923 | 17990 | Centrally Ducted | Ducted | 17990 | 107.79 | $4,825.00 | $1,840.00 | $3,115.00 | $2,800.00 | $247.08 | $4,500.00 | $0.00 | $0.00 | $0.00 | $17,327.08 | No | $2,500 | |||||||||||||||||||||||||
72 | 7/28/2020 | Somerville | Custom Air Systems - Matthew Gleason | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1129 | 16862 | 1910-1919 | Natural Gas Steam Boiler | 86 | No | The previous primary heating system is being removed | More than 20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | Yes | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU36RLXFZH | 8908615 | 36407 | Multi-head minisplit | Ductless | 36407 | 215.91 | $5,951.00 | $250.00 | $8,549.00 | $800.00 | $75.00 | $0.00 | $1,000.00 | $0.00 | $0.00 | $16,625.00 | No | $2,500 | |||||||||||||||||||||||||
73 | 6/22/2020 | Jamaica Plain | Sum Zero Energy Systems - David Sampaio | Eversource | Existing building | N/A - Existing Building | 3 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1232 | 20552 | 1900-1909 | Natural Gas Hot Water Boiler | 110 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 5-10 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home; Solar Hot Water | No | Window Unit(s); Ceiling Fan | Stove/oven; Domestic Hot Water | Stove/oven | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-3C24NAHZ2 | 201754904 | 25000 | Mitsubishi | MXZ-2C20NAHZ2 | 201754904 | 22000 | Multi-head minisplit | Ductless | 47000 | 228.69 | $9,500.00 | $5,000.00 | $3,000.00 | $1,500.00 | $100.00 | $0.00 | $0.00 | $0.00 | $7,100.00 | $26,200.00 | Yes | $5,000 | |||||||||||||||||||||
74 | 7/23/2020 | Boston | A. Moschella Refrigeration LLC - Anthony Moschella | Eversource | Existing building | N/A - Existing Building | 6 units in building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 863 | 24865 | 1980-1989 | Natural Gas Hot Water Boiler | 23 | No | The previous primary heating system is being left in place, but turned off or disabled | More than 20 years old | Less than 50% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | stovetop | N/A | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Ductless | 28600 | 115.02 | $6,900.00 | $0.00 | $6,600.00 | $1,000.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $14,500.00 | No | $2,500 | |||||||||||||||||||||||||
75 | 6/26/2020 | Quincy | Airco Home Comfort Services, LLC - James Carnevale | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1199 | 25351 | 1940-1949 | Natural Gas Hot Water Boiler | 120 | Yes, through a tankless coil | The previous primary heating system is being left in place and operational | Less than 5 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RLXFZH | 8063925 | 25625 | Mixed of single- and multi-head minisplits | Mix of ducted and ductless | 25625 | 101.08 | $6,978.00 | $2,030.00 | $4,995.00 | $1,995.00 | $0.00 | $3,000.00 | $0.00 | $0.00 | $0.00 | $18,998.00 | No | $2,500 | |||||||||||||||||||||||||
76 | 6/26/2020 | Boston | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1105 | 22411 | 1960-1969 | Natural Gas Hot Water Boiler | 150 | No | The previous primary heating system is being left in place and operational | 10-15 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU24RGLX | 202537547 | 22220 | Centrally Ducted | Ducted | 22220 | 99.15 | $6,000.00 | $1,193.00 | $2,500.00 | $1,500.00 | $0.00 | $5,700.00 | $0.00 | $0.00 | $0.00 | $16,893.00 | No | $2,500 | |||||||||||||||||||||||||
77 | 7/6/2020 | Newton | Airco Home Comfort Services, LLC - James Carnevale | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1495 | 35340 | 1920-1929 | Natural Gas Furnace | 100 | No | The previous primary heating system is being left in place and operational | 10-15 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven; Domestic Hot Water; Clothes Dryer | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU36RLXFZH | 8908615 | 36407 | Multi-head minisplit | Ductless | 36407 | 103.02 | $12,000.00 | $998.00 | $4,000.00 | $2,000.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $18,998.00 | No | $2,500 | |||||||||||||||||||||||||
78 | 8/12/2020 | Blackstone | NV Heating and Air Conditioning LLC - Keith Ritacco | National Grid | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 962 | 23704 | 1990-1999 | Natural Gas Hot Water Boiler | 100 | Yes, through a tankless coil | The previous primary heating system is being left in place and operational | Less than 5 years old | Greater than 95% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s); Ceiling Fan; Window Fan | Stove/oven; Domestic Hot Water; Clothes Dryer | None | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Fujitsu | AOU36RLXFZH | 8908615 | 36407 | Multi-head minisplit | Ductless | 36407 | 153.59 | $6,595.00 | $2,265.00 | $3,290.00 | $850.00 | $200.00 | $0.00 | $0.00 | $0.00 | $0.00 | $13,200.00 | No | $2,500 | |||||||||||||||||||||||||
79 | 8/12/2020 | Clinton | Airise HVAC Design Inc. - Seik Deoliveira | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1504 | 24452 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU300HHV | 10525928 | 27800 | Centrally Ducted | Ducted | 27800 | 113.69 | $4,800.00 | $2,100.00 | $4,470.00 | $850.00 | $100.00 | $980.00 | $0.00 | $0.00 | $300.00 | $13,600.00 | No | $2,500 | |||||||||||||||||||||||||
80 | 8/12/2020 | Clinton | Airise HVAC Design Inc. - Seik Deoliveira | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1753 | 20985 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU300HHV | 10525928 | 27800 | Centrally Ducted | Ducted | 27800 | 132.48 | $6,300.00 | $2,100.00 | $5,470.00 | $850.00 | $100.00 | $980.00 | $0.00 | $0.00 | $0.00 | $15,800.00 | No | $2,500 | |||||||||||||||||||||||||
81 | 8/12/2020 | Clinton | Airise HVAC Design Inc. - Seik Deoliveira | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1498 | 27449 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU300HHV | 10445377 | 27000 | Centrally Ducted | Ducted | 27000 | 98.36 | $4,800.00 | $2,100.00 | $4,470.00 | $850.00 | $100.00 | $980.00 | $0.00 | $0.00 | $300.00 | $13,600.00 | No | $2,500 | |||||||||||||||||||||||||
82 | 8/12/2020 | Clinton | Airise HVAC Design Inc. - Seik Deoliveira | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1498 | 27449 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU300HHV | 10445377 | 27000 | Centrally Ducted | Ducted | 27000 | 98.36 | $4,800.00 | $2,100.00 | $4,470.00 | $850.00 | $100.00 | $980.00 | $0.00 | $0.00 | $300.00 | $13,600.00 | No | $2,500 | |||||||||||||||||||||||||
83 | 8/14/2020 | Haverhill | ReVision Energy Inc. - Frank Kuteesa | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1035 | 18494 | 1990-1999 | Natural Gas Hot Water Boiler | 70 | No | The previous primary heating system is being left in place, but turned off or disabled | More than 20 years old | 80%-85% | Wood fireplace | No | Window Unit(s) | Domestic Hot Water | N/A | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Ductless | 28600 | 154.64 | $6,500.00 | $750.00 | $5,800.00 | $1,504.00 | $150.00 | $0.00 | $0.00 | $0.00 | $0.00 | $14,704.00 | Yes | $5,000 | |||||||||||||||||||||||||
84 | 9/29/2020 | Watertown | Custom Air Systems - Matt Gleason | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1074 | 35434 | 1950-1959 | Natural Gas Furnace | 125 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | Less than 5 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Bosch | BOVA-36HDN1-M18M | 202868496 | 23000 | Centrally Ducted | Ducted | 23000 | 64.91 | $4,700.00 | $0.00 | $4,700.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $9,400.00 | No | $2,500 | |||||||||||||||||||||||||
85 | 10/2/2020 | Brookline | Ace Energy Services, Inc. - Inette Rex | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1287 | 26969 | 1910-1919 | Natural Gas Steam Boiler | 72 | No | The previous primary heating system is being removed | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven | Stove/oven | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ3C24NAHZ | 201754904 | 25000 | Mitsubishi | MUZ-FH06NAH | 201754427 | 8700 | Multi-head minisplit | Ductless | 33700 | 124.96 | $10,854.78 | $0.00 | $6,320.00 | $500.00 | $300.00 | $0.00 | $0.00 | $455.22 | $0.00 | $18,430.00 | No | $3,000 | |||||||||||||||||||||
86 | 9/15/2020 | Billerica | Net Zero Heating & Air Conditioning, LLC - Steve Smith | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2353 | 55733 | 1960-1969 | Natural Gas Hot Water Boiler | 145 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 10-15 years old | 80%-85% | Wood stove | No | Window Unit(s) | Domestic Hot Water | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (VRF) | 2 | Mitsubishi | MXZ-4C36NAHZ2 | 204834292 | 45000 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Multi-head minisplit | Ductless | 73600 | 132.06 | $15,640.33 | $3,348.39 | $5,800.00 | $935.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $25,723.72 | No | $2,500 | |||||||||||||||||||||
87 | 2/1/2021 | Arlington | MasterCraft Mechanical, Inc. - Ernie Guarino | Eversource | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2498 | 33309 | 2010-Present | Natural Gas Furnace | 60 | No | The previous primary heating system is being removed | 5-10 years old | Greater than 95% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System; Ceiling Fan | Stove/oven; Domestic Hot Water; Clothes Dryer | none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 4 | BOSCH | BOVA-36HDN1-M20G | 202868496 | 23000 | Fujitsu | AOU12RLS3H | 8703506 | 16500 | MUZ-FH09NAH | MUZ-FH09NAH | 201754297 | 10900 | Fujitsu | AOU12RLS3H | 8703506 | 16500 | Mixed of single- and multi-head minisplits | Mix of ducted and ductless | 66900 | 200.85 | $27,061.63 | $0.00 | $0.00 | $1,200.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $28,261.63 | No | $2,500 | |||||||||||||
88 | 10/2/2020 | Needham | Ace Energy Services, Inc. - Inette Rex | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1808 | 37083 | 2000-2009 | Natural Gas Furnace | 95 | No | The previous primary heating system is being removed | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | MITSUBISHI | SUZ-KA18NAHZ | 204627022 | 21600 | MITSUBISHI | SUZ-KA18NAHZ | 204627022 | 21600 | Centrally Ducted | Ducted | 43200 | 116.5 | $8,829.34 | $0.00 | $3,500.00 | $500.00 | $0.00 | $2,000.00 | $500.00 | $551.83 | $2,383.83 | $18,265.00 | No | $3,000 | |||||||||||||||||||||
89 | 10/2/2020 | Needham | Ace Energy Services, Inc. - Inette Rex | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1808 | 35349 | 2000-2009 | Natural Gas Furnace | 95 | No | The previous primary heating system is being removed | 15-20 years old | 85%-90% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Stove/oven; Domestic Hot Water | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | MITSUBISHI | SUZ-KA18NAHZ | 204627022 | 21600 | MITSUBISHI | SUZ-KA18NAHZ | 204627022 | 21600 | Centrally Ducted | Ducted | 43200 | 122.21 | $8,829.34 | $0.00 | $3,500.00 | $500.00 | $0.00 | $2,000.00 | $500.00 | $551.83 | $2,393.83 | $18,275.00 | No | $3,000 | |||||||||||||||||||||
90 | 10/19/2020 | Framingham | Sum Zero Energy Systems - David Sampaio | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2772 | 37200 | 1950-1959 | Natural Gas Hot Water Boiler | 202 | No | The previous primary heating system is being left in place, but turned off or disabled | More than 20 years old | Unknown | Wood fireplace | No | Central AC System | Stove/oven; Domestic Hot Water; Clothes Dryer | Stove/oven; Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | PUZ-HA36NHA5 | 201754323 | 38000 | Centrally Ducted | Ducted | 38000 | 102.15 | $8,050.00 | $2,200.00 | $4,000.00 | $950.00 | $200.00 | $2,200.00 | $400.00 | $0.00 | $0.00 | $18,000.00 | No | $2,500 | |||||||||||||||||||||||||
91 | 10/30/2020 | Arlington | Ace Energy Services, Inc. - Inette Rex | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1777 | 18012 | 1930-1939 | Natural Gas Steam Boiler | 108 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being removed | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Stove/oven | Stove/oven; Domestic Hot Water; Clothes Dryer | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 4 | MITSUBISHI | MUZ-FH06NAH | 201754427 | 8700 | MITSUBISHI | MUZ-FH06NAH | 201754427 | 8700 | MUZ-FH06NAH | MUZ-FH06NAH | 201754427 | 8700 | Mitsubishi | MUZ-FH09NAH | 201754297 | 10900 | Multi-head minisplit | Ductless | 37000 | 205.42 | $6,742.00 | $2,081.00 | $9,128.00 | $0.00 | $0.00 | $0.00 | $500.00 | $399.00 | $0.00 | $18,850.00 | No | $3,000 | |||||||||||||
92 | 12/2/2020 | Milton | Sum Zero Energy Systems - David Sampaio | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2419 | 44033 | 1940-1949 | Natural Gas Hot Water Boiler | 96 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place, but turned off or disabled | 15-20 years old | 50%-75% | electric radiant heat | No | Window Unit(s) | Stove/oven; Clothes Dryer | Clothes Dryer; none | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-3C30NAHZ2 | 201754908 | 28600 | Mitsubishi | MXZ-3C24NAHZ2 | 201755016 | 24800 | Multi-head minisplit | Mix of ducted and ductless | 53400 | 121.27 | $10,300.00 | $4,500.00 | $6,000.00 | $1,200.00 | $300.00 | $2,800.00 | $0.00 | $0.00 | $0.00 | $25,100.00 | No | $3,000 | |||||||||||||||||||||
93 | 11/17/2020 | Montague | Gates HVACR LLC - John Gates | Eversource | New construction (including gut rehab) | New construction | Single-family (detached) | Energy Star Certified Home | No | Other | None | 1152 | 16891 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Wood stove | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Standard electric cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | Fujitsu | AOU18RLFXZH | 8033584 | 22000 | Multi-head minisplit | Ductless | 22000 | 130.25 | $3,500.00 | $1,000.00 | $4,300.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $8,800.00 | No | $2,500 | |||||||||||||||||||||||||
94 | 11/17/2020 | Needham | Ace Energy Services, Inc. - Inette Rex | Eversource | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 3567 | 35259 | 2000-2009 | Natural Gas Furnace | 78 | No | The previous primary heating system is being removed | 10-15 years old | 90%-95% | No, the air-source heat pumps are the only source of space heating in the home | No | Central AC System | Domestic Hot Water | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | MITSUBISHI | SUZKA18NAHTH | 204627056 | 21600 | MITSUBISHI | MXZ3C24NAHZ | 201754904 | 25000 | Multi-head minisplit | Mix of ducted and ductless | 46600 | 132.16 | $10,965.17 | $3,526.85 | $8,227.90 | $0.00 | $300.00 | $2,200.00 | $500.00 | $580.08 | $0.00 | $26,300.00 | No | $3,000 | |||||||||||||||||||||
95 | 12/2/2020 | Clinton | Ace Energy Services, Inc. - Inette Rex | National Grid | New construction (including gut rehab) | New construction | Single-family (detached) | Massachusetts Stretch Code; HERS Rating Target (describe below) | Yes | Natural gas | Central AC System | 1804 | 20985 | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | No, the air-source heat pumps are the only source of space heating in the home | N/A - New Construction | N/A - New Construction | N/A - New Construction | N/A - New Construction | Induction cooktop - Electric Oven | Heat Pump Water Heater | Standard Electric Clothes Dryer | Air-to-air (Standard) | 1 | LG | LMU300HHV | 10525928 | 27800 | Multi-head minisplit | Mix of ducted and ductless | 27800 | 132.48 | $6,300.00 | $2,100.00 | $5,470.00 | $850.00 | $100.00 | $980.00 | $0.00 | $0.00 | $0.00 | $15,800.00 | No | $2,500 | |||||||||||||||||||||||||
96 | 1/28/2021 | Boston | New England Ductless - Joseph Wood | Eversource | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1889 | 30891 | Before 1900 | Natural Gas Furnace | 30 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being left in place and operational | 5-10 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Existing Heat Pumps | Stove/oven; Domestic Hot Water | NA | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 1 | Mitsubishi | MXZ-4C36NAHZ2-U1 | 201754911 | 45000 | Multi-head minisplit | Ductless | 45000 | 145.67 | $12,844.96 | $0.00 | $9,000.00 | $2,000.00 | $0.00 | $0.00 | $499.00 | $0.00 | $0.00 | $24,343.96 | No | $2,500 | |||||||||||||||||||||||||
97 | 2/11/2021 | Acton | Lavallee Systems - Samuel Wallace | Eversource | Existing building | N/A - Existing Building | Single-family attached (e.g., townhouse) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1757 | 28872 | 1990-1999 | Natural Gas Hot Water Boiler | 100 | Yes, through a tankless coil | The previous primary heating system is being left in place and operational | 10-15 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | No | Window Unit(s) | Domestic Hot Water | no | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Fujitsu | AOU18RLXFZH | 8033584 | 22000 | Fujutsu | AOU9RLFC | 5751312 | 15000 | Mixed of single- and multi-head minisplits | Mix of ducted and ductless | 37000 | 128.15 | $5,000.00 | $2,000.00 | $11,000.00 | $3,000.00 | $500.00 | $3,000.00 | $0.00 | $0.00 | $0.00 | $24,500.00 | No | $3,000 | |||||||||||||||||||||
98 | 3/12/2021 | Jamaica Plain | Lavallee Systems - Samuel Wallace | Eversource | Existing building | N/A - Existing Building | 2 unit | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 2200 | 27763 | 1900-1909 | Natural Gas Steam Boiler | 65 | No | The previous primary heating system is being removed | 15-20 years old | 80%-85% | No, the air-source heat pumps are the only source of space heating in the home | Yes | Window Unit(s); Existing Heat Pumps | Stove/oven; Domestic Hot Water | Stove/oven; Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | SUZ-KA18NAHZ | 204627056 | 21600 | Mitsubishi | SUZ-KA15NA | 201754497 | 11900 | Centrally Ducted | Ducted | 33500 | 120.66 | $10,000.00 | $1,000.00 | $10,000.00 | $3,000.00 | $1,000.00 | $10,000.00 | $2,000.00 | $1,000.00 | $0.00 | $38,000.00 | No | $2,167 | |||||||||||||||||||||
99 | 2/1/2021 | Lexington | ReVision Energy Inc. - Frank Kuteesa | Eversource | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1962 | 40653 | 1960-1969 | Natural Gas Hot Water Boiler | 124 | Yes, through an indirect domestic hot water tank | The previous primary heating system is being removed | 15-20 years old | 85%-90% | Supplemental electric resistance heat | No | Central AC System | Stove/oven | Domestic Hot Water | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 3 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 22000 | Mitsubishi | MXZ-2C20NAHZ2 | 202732309 | 22000 | SUZ-KA12NAHZ | SUZ-KA12NAHZ | 204627062 | 15000 | Mixed of single- and multi-head minisplits | Ductless | 59000 | 145.13 | $14,975.00 | $691.00 | $9,040.00 | $3,013.00 | $500.00 | $0.00 | $0.00 | $0.00 | $0.00 | $28,219.00 | No | $2,500 | |||||||||||||||||
100 | 2/11/2021 | Worcester | Energy Monster - Michael Heil | National Grid | Existing building | N/A - Existing Building | Single-family (detached) | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | 1872 | 48584 | 1900-1909 | Natural Gas Furnace | 81 | No | The previous primary heating system is being removed | 10-15 years old | 90%-95% | Solar Hot Water | No | None | Stove/oven; Domestic Hot Water | Stove/oven | N/A - Existing Building | N/A - Existing Building | N/A - Existing Building | Air-to-air (Standard) | 2 | Mitsubishi | MXZ-3C24NAHZ2-U1 | 201754904 | 25000 | mitsubishi | MXZ-3C24NAHZ2-U1 | 201754904 | 25000 | Multi-head minisplit | Ductless | 50000 | 102.91 | $8,260.00 | $1,547.40 | $12,586.79 | $1,000.00 | $300.00 | $0.00 | $0.00 | $1,458.81 | $0.00 | $25,153.00 | No | $2,500 | |||||||||||||||||||||