PROJECT TITLE:
NBT Villa
SHEET No.
3
DESCRIPTION:
Retaining Wall
MADEDATERev.
4
REF:SR24-févr.-26
5
LOCATION :
Riyadh
CHECKEDDATE0
6
DESIGN OF CANTILEVER RETAINING WALL PER ACI318-05ZA 25-févr.-26
7
8
9
10
b) Geometry input
detail
11
12
B=7,00m
13
b1=1,50m
14
Df=2,50m
15
ts=1,50m
16
he=11,10m
17
a=0,00m
18
t1=1,00m1,33
19
t2=0,50m
20
21
b2=4,50m
22
SECTION A-A & B-B
h=12,60m
23
H=12,60m
24
1)
Design Inputs
25
a)
Material
26
Concrete grade
fc=35
Mpa
27
Steel grade
fy=420
Mpa
28
Material factor
f=0,9
29
Conrete density
gc=24
kN/m3
30
Soil density
gs=18
kN/m3
31
Angle of repose for soil
θ=30
degree
32
Coefficient of active earth pressure ka =
ka=0,33
redian
33
34
Coefficient of passive earth pressure ka =
35
36
37
Safe Bearing Capacity
fb.all
=500
kPa
38
Coeff of friction for Sliding
m=0,5
39
c)
Loading
40
Surcharge pressure
q=12
kN/m2
41
Design Summary
42
F.S against Overturning
=
2,51 > 1.5 Safe !!
43
F.S against Sliding
=
1,33 < 1.5 Not Safe!! Hence Provide shear Key
44
Max. bearing pressure
=
372,63 kPa < 500 kPa Hence Safe
45
Wall Main reinforcement
=
16 @ 25c/c
46
Heel Top Main reinforcement
=
20 @ 75c/c
47
Toe bottom main reinforcement
=
16 @ 50c/c
48
2)
Design Output
49
2.1)
Stability Calculation
50
a)
Check for Overturning
51
52
53
54
55
56
57
58
59
60
61
249,8260933
62
298,947656
63
372,6328,77906122
64
249,8260933
65
298,947656
66
Calculation of overturning moment about "O"
67
Load mkd
Load (kN)
Distance(m)
Mo (kNm)
68
H1476,284,22000,376
69
H250,46,3317,52
70
Total
526,68kN2317,896
kNm
71
72
Calculation of Restoring Moment about "O"
73
Load mkd
Load (kN)
Distance(m)
Mro(kNm)
74
W1899,14,754270,725
75
W22523,5882
76
W3133,22,25299,7
77
W466,61,83122,1
78
W5544,75256,5
79
Total
1404,9kN5831,0
kNm
80
81
Total Overturning Moment
Mo=2317,9
kNm
82
Total Restoring Moment
Mro=5831,1
kNm
83
Factor of Safety
=
Mro/Mo
=
5831,1 / 2317,9
=2,51
> 1.5
Safe !!
84
85
86
b)
Check for Sliding
87
Total Horizontal force
H=526,7kN
88
Restoring force =
m x SW
=
0,5 x 1404,9
Hr=702,45kN
89
Factor Safety
=
Hr/H
=
702,45/526,7
=1,33
< 1.5
Not Safe!!
90
91
Hence Provide shear Key
92
93
c)
Check for Bearing pressure
94
C.g of Load
x=
(Mro-Mo)/P
=2,500625667
95
eccentricity
e=
B/2 - x
=0,9993743327
96
fbmax
=
P/A(1 + 6.e/B)
=372,63
kPa
< 500 kPa
97
fbmin
=
P/A(1 - 6.e/B)
=28,77906122
kPa
> 0
98
Hence Safe
99
2.2)
Structural Design
100
a)
Design of Stem (vertical reinforcement - inner face-(1))