ABCEFGHIJKLMNOPQRSTUVWXYZ
1
Parameter NameParameter IDSetting NotesValues
2
ActivationRAC algorithm switchCellAlgoSwitch.RacAlgoSwitchFor GBR services, it is recommended that this option be selected.
DlSwitch:Off, UlSwitch:Off, DlLdcSwitch:Off, UlLdcSwitch:Off, PreemptionSwitch:Off, PttAcSwitch:Off, VoltePrefAdmissionSwitch:Off, VoltePreemptionSwitch:Off, UeExpBasedCongCtrlSw:Off, EmcAdmitCongSwitch:Off, DlDelayBasedSatisStatSw:Off
3
ActivationRAC algorithm switchCellAlgoSwitch.RacAlgoSwitchFor GBR services, it is recommended that this option be selected.
DlSwitch:Off, UlSwitch:Off, DlLdcSwitch:Off, UlLdcSwitch:Off, PreemptionSwitch:Off, PttAcSwitch:Off, VoltePrefAdmissionSwitch:Off, VoltePreemptionSwitch:Off, UeExpBasedCongCtrlSw:Off, EmcAdmitCongSwitch:Off, DlDelayBasedSatisStatSw:Off
4
ActivationRAC algorithm switchCellAlgoSwitch.RacAlgoSwitchFor non-GBR services, it is recommended that this option be selected.
DlSwitch:Off, UlSwitch:Off, DlLdcSwitch:Off, UlLdcSwitch:Off, PreemptionSwitch:Off, PttAcSwitch:Off, VoltePrefAdmissionSwitch:Off, VoltePreemptionSwitch:Off, UeExpBasedCongCtrlSw:Off, EmcAdmitCongSwitch:Off, DlDelayBasedSatisStatSw:Off
5
CongestionCCE Usage ThresholdCellRacThd.CceUsageThd8080
6
CongestionCongestion ThresholdCellQciPara.CongestionThreshold6565
7
CongestionOffset for service congest relievingCellRacThd.CongRelOffset2020
8
CongestionHigh RB Usage ThldCellRacThd.UlRbHighThd9595
9
CongestionLow RB Usage ThldCellRacThd.UlRbLowThd9090
10
CongestionRedirection switch
ENodeBAlgoSwitch.RedirectSwitch
If congestion control is enabled, it is recommended that this option be selected to redirect UEs whose RRC connections are released due to congestion control to other frequencies, preventing these UEs from experiencing re-access failures.
LoadBasedSwitch:Off, GeranFlashRedirectSwitch:Off, UranFlashRedirectSwitch:Off, LoadRedirectFreqOptSwitch:Off
11
CongestionRedirection switch
ENodeBAlgoSwitch.RedirectSwitch
If congestion control is enabled, it is recommended that this option be selected to prevent UEs from experiencing ping-pong redirection among multiple frequencies.
LoadBasedSwitch:Off, GeranFlashRedirectSwitch:Off, UranFlashRedirectSwitch:Off, LoadRedirectFreqOptSwitch:Off
12
Optimization
CCE Allocation Failure High Threshold
CellRacThd.CceAlFailHighThd4040
13
OptimizationRB Congestion High ThresholdCellRacThd.RbCongHighThd9595
14
OptimizationCQI Threshold for Far UsersCellRacThd.CqiFarThd55
15
OptimizationDL Experience Rate ThresholdCellRacThd.DlExperienceThd200200
16
OptimizationUL Experience Rate ThresholdCellRacThd.UlExperienceThd1616
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100