ABCDEFGHIJKLMNOPQRSTUVWXYZAAABAC
1
2
VoltsCharge %VoltsCharge %VoltsCharge %VoltsCharge %Cell Volts (corresponds to chart at left)Charge % Calculation Method*Quick ReferenceOther Charge Charts
3
84.010078.07572.05066.0254.2003.9003.6003.30020 x [cell volts] = charge volts%VoltsClick Me
4
83.89977.87471.84965.8244.1883.8883.5883.28810084.0
5
83.59877.57371.54865.5234.1763.8763.5763.276Voltage Increment9081.6
6
83.39777.37271.34765.3224.1643.8643.5643.2640.012v8079.2
7
83.09677.07171.04665.0214.1523.8523.5523.2527076.8
8
82.89576.87070.84564.8204.1403.8403.5403.2406074.4
9
82.69476.66970.64464.6194.1343.8283.5283.2285072.0
10
82.39376.36870.34364.3184.1163.8163.5163.2164069.6
11
82.19276.16770.14264.1174.1043.8043.5043.2043067.2
12
81.89175.86669.84163.8164.0923.7923.4923.192*100% Charge Example Calc:2064.8
13
81.69075.66569.64063.6154.0803.7803.4803.18020 * 4.200 = 84.0v battery charge1062.4
14
81.48975.46469.43963.4144.0683.7683.4683.168
15
81.18875.16369.13863.1134.0563.7563.4563.156
- Cell is assumed to be a typical 18650 or 21700 with full charge at 4.2v and full discharge at 3.0v
16
80.98774.96268.93762.9124.0443.7443.4443.144
- Calculation formula produces mathematically correct but real-world-ballpark values.
17
80.68674.66168.63662.6114.0323.7323.4323.132
What does ballpark mean? Just because you have a 75% charge does not mean you have 75% of your total range
18
80.48574.46068.43562.4104.0203.7203.4203.120
left before shutdown. Different batteries behave a bit differently as they discharge, So additionally Voltage X will
19
80.28474.25968.23462.294.0083.7083.4083.108
vary from Percentage Y by at least a bit. This chart only shows where you are on a 'perfect mathematical ' curve.
20
79.98373.95867.93361.983.9963.6963.3963.096
If you must, figure out yours for yourself thru experience with your pack - and re-factor and adjust as it ages.
21
79.78273.75767.73261.773.9843.6843.3843.084
- If you are serious about individualizing your chart to your own cells, start here (good luck)
22
79.48173.45667.43161.463.9723.6723.3723.072
http://lygte-info.dk/review/batteries2012/Common18650IndividualTest%20UK.html
23
79.28073.25567.23061.253.9603.6603.3603.060
24
79.07973.05467.02961.043.9483.6483.3483.048Are you a programmer? Make your own damn chart:
25
78.77872.75366.72860.733.9363.6363.3363.036 counter% = 0
vCurrent% = 3.000
vIncrement% = 0.012
vPack% = 20
DIM vValue%(100)
WHILE counter% < 101
vValue%(counter%) = vCurrent% * vPack%
vCurrent% = vCurrent% + vIncrement%
counter% = counter% + 1
WEND
MEMORY
26
78.57772.55266.52760.523.9243.6243.3243.024
27
78.27672.25166.22660.213.9123.6123.3123.012
28
60.003.000
29
30
Internet use: You can link to this page and post that link anywhere on the web.
31
Copies or screen shots: You can make copies only for your own use so long as they are never posted on the internet
32
SHARE REQUESTS: Want the Excel Source? Sorry there is none. I'm a programmer and used code similar to what I lay out in the 'make your own chart' box at right as well as the input cues in the Calculation Method box. Beyond that these charts were done manually. Which is not as much work as it seems as the voltages were done at different times over a couple of years before they were gathered together in the blog.
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100