ABCDEFGHIJKLMNOPQRSTUVWXYZAAABACADAEAFAGAHAI
1
NOKKSBIDANGINDIKASI PERMASALAHANJUDUL PEKERJAANURAIAN PEKERJAANNOMOR
WORK ORDER
TIPE WOPRIORITASJADWAL START PEKERJAANJADWAL SELESAI PEKERJAANAKTUAL START PEKERJAANAKTUAL SELESAI PEKERJAANSTATUS
2
3
4
exKKS diisi rendalhardiisi dari hardiisi oleh operasidiisi dari har/rendaldiisi dari har dan rendaldiisi rendalharPAMdiisi rendalhardiisi rendalhardiisi rendalhardiisi rendalhardiisi rendalhardiisi rendalhar
5
1MECHPERBAIKAN LINE PIPA ASH COOLER PUMP INDIKASI BOCORWO101335PAMNORMAL27-02-2024 15:1527-03-2024 15:1627/02/2024 15:15:0027/02/2024 15:15:00CLOSE
6
2MECHBOILER #2 REL SCRAPER INDIKASI TERLEPASWO101337PAMNORMAL28-02-2024 9:0328-03-2024 9:0328/02/2024 9:03:0028/02/2024 9:03:00CLOSE
7
3130409TD10ETA10AF001MECHINSPEKSI DAN PERBAIKAN ROLLER ASH COOLER #1 INDIKASI TIDAK BISA BERPUTAR NORMALPERMASLAHAN : ROLLER ASH COLLER RUSAK
PENYEBAB :
LANGKAH PENYELESAIAN : DILAKUKAN PENGGANTIAN ROLLER BARU
WO101295PAMNORMAL26/02/2024 8:14:0026/03/2024 8:14:0027/02/2024 8:14:0027/02/2024 8:14:00CLOSE
8
4130409TD20LCW01BB1110BI&CPI VACUUM WATER EJECTOR PUMP #2 (ABNORMAL)PERMASALAHAN : INDIKASI PI VACUUM WATER EJECTOR PUMP #2 ABNORMAL

PENYEBAB :

PENYELESAIAN : - TUTUP VALVE INLET PI DAN BERI TAGING PTW
- LEPAS PI DAN LAKUKAN KALIBRASI
- TEMUAN : PEMBACAAAN PI STUCK DI -0075 MPA
- STOCK GUDANG KOSONG, MENUNGGU PEMBELIAN MATERIAL FAST MOVING
- PASANG PI DAN BUKA VALVE INLET PI LALU LEPAS TAGING PTW ( FINISH)
WO101094PAMNORMAL21-02-2024 12:2221-02-2024 12:2221-02-2024 14:0421/02/2024 14:04:00CLOSE
9
5130409TD00GAF02AP1115BMECHINSPEKSI DAN PERBAIKAN KEBOCORAN LINE RO PUMP TO CLARIFIERPERMASALAHAN : KEBOCORAN LINE RO TO CLARIFIER

PENYEBAB : SAMBUNGAN PECAH

PENYELESAIAN : DILAKUKAN PEMOTONGAN LINE YANG LAMA DAN SAMBUNGKAN KEMBALI
WO101334PAMNORMAL26-02-2024 9:1826-03-2024 9:1827-02-2024 14:2027-02-2024 17:20CLOSE
10
6130409TD10HFB20AF001ELECINSPEKSI SCREW FEEDER NO.2 BOILER UNIT 1PERMASALAHAN : INDIKASI SCREW FEEDER NO 2 DI LOKAL STOP DI CCR RUNNING
PENYEBAB : KABEL POWER KE MOTOR HANGUS DAN SHORT

PENYELESAIAN : - LEPAS KABEL POWER KE MOTOR, TES RUNNING INVERTER (OK)
- CONTINUITY KABEL POWER KE MOTOR
- PENYAMBUNGAN DAN REISOLASI KABEL POWER KE MOTOR
WO101523PAMNORMAL28-02-2024 10:2528-03-2024 10:2528-02-2024 10:2528-02-2024 10:25CLOSE
11
7130409TD10HNC10AN002I&CPENGECEKAN PI ASH REINJECTION UNIT 1PERMASALAHAN : PI ASH REINJECTION ABNORMAL

PENYEBAB : PI INDIKASI RUSAK

PENYELESAIAN : DILAKUKAN PENGGANTIAN PI BARU
WO100538PAMNORMAL02-02-2024 11:0303-02-2024 11:0427-02-2024 14:1327-02-2024 14:13CLOSE
12
8MECHCommon : Tuas selenoit PTO 1 damkar macet
13
9130409TD00GCF02AP001AMECHINSPEKSI DAN PERBAIKAN HPP A BWRO WTP1WO101526PAMNORMAL27-02-2024 19:5727-03-2024 19:57WAPPR
14
10130409TD20PAC06AP1110CI&CINSPEKSI PI COOLING BOOSTER PUMP C #2PERMASALAHAN: INDIKASI PI MASIH TERBACA 2.7 BAR SAAT POMPA STOPWO101800PAMNORMAL08-03-2024 10:1108-04-2024 10:11INPROGRES
15
11130409TD00SGA01AP1130ELECINSPEKSI DAN PERBAIKAN MOTOR ELECTRIK FIRE PUMP INDIKASI SHORTWO101524PAMNORMAL26-02-2024 16:0126-03-2024 16:01WAPPR
16
12130409TD00QEA03KN4101CELECPERBAIKAN FAN MOTOR IAC C INDIKASI PATAHWO101525PAMNORMAL26-02-2024 16:0726-03-2024 16:07CLOSE
17
13130409TD10PGA02AP1105BMECHPENORMALAN POMPA CCWP B #1WO101527PAMNORMAL26-02-2024 20:0926-03-2024 20:09CLOSE
18
14130409TD00EAC01Z100AELECINSPEKSI DAN PERBAIKAN MOTOR VIBRATING LINE A INDIKASI ADA PERCIKAN APIPERMASALAHAN :
- Motor vibrating line A ada indikasi percikan pada terminasi motor

PENYEBAB :
- Kerdapat kabel 1 phase putus

PENYELESAIAN :
- Dilakukan pengujian tahanan isolasi motor
- Dilakukan re-skun kabel power to motor
WO101528PAMNORMAL01-03-2024 8:1901-04-2024 8:19CLOSE
19
15130409TD20MAK01AE0001ELECPENORMALAN MOTOR TGM TURBIN #2PERMASALAHAN :
- Indikasi motor TGM ketika running langsung stop

PENYEBAB :
- Indikasi motor TGM kemasukan air (belitan lembab)

PENYELESAIAN :
- Dilakukan cleaning dan Heating Belitan motor
- Pemeriksaan dan penambahan isolasi belitan (Red Varnish)
- Dilakukan pengujian tahanan isolasi motor
- Dilakukan solorun tes hasil (OK)
WO101531PAMNORMAL03-03-2024 10:4003-04-2024 10:40CLOSE
20
16130409TD00QSC01AT001MECHTurbin : Cleaning Purifier WO101530PAMNORMAL04-03-2024 10:3404-04-2024 10:34CLOSE
21
17130409TD00EAC01Z100BMECHCommon : Inspeksi Bearing Vibrating Screen Line BWO101529PAMNORMAL04-03-2024 10:1504/04/2024CLOSE
22
18130409TD00GCF02BB002MECHPENAMBAHAN HCL DAN NaOH MIXBET WTP 2WO101534PAMNORMAL04-03-2024 15:2704-04-2024 15:27CLOSE
23
19130409TD00GCB01AT002MECHPENGGANTIAN CARTRIDGE SWRO WTP 2WO101627PAMNORMAL04-03-2024 15:2704-04-2024 15:27CLOSE
24
20130409TD10BGA03GS001ELECINSPEKSI DAN PERBAIKAN MOTOR WATER JET PUMP B #1 INDIKASI TERBAKAR DI SISI KABELPERMASALAHAN :
- Temuan PM : - Indikasi kabel power pada terminasi motor water jet B hangus
- Baut pada Termanal kabel sudah longgar

PENYEBAB :
- Over Heat, arus operasi sudak maximal

PENYELESAIAN :
- Re-skun kabel power ke motor
- Pengeleman baut pada terminal kabel
WO101630PAMNORMAL06-03-2024 10:3406-04-2024 10:34CLOSE
25
21130409TD10HFB10BN001ELECBOILER #1 : INDIKASI KABEL POWER MOTOR SPREADER No.1 UNIT 1 HANGUSPERMASALAHAN : INDIKASI SPREADER NO 1 DI LOKAL STOP

PENYEBAB : INDIKASI KABEL POWER KE MOTOR HANGUS DAN SHORT

PENYELESAIAN : - LEPAS KABEL POWER KE MOTOR, TES RUNNING INVERTER (OK)
- CONTINUITY KABEL POWER KE MOTOR
- PENYAMBUNGAN DAN REISOLASI KABEL POWER KE MOTOR
- Penggantian kabel
WO101628PAMNORMAL05-03-2024 10:5305-04-2024 10:53CLOSE
26
22MECHSERVICE BERKALA EXCAVATOR 04 HM 1050014/03/2024

PERMASALAHAN : SERVICE BERKALA EXCAVATOR 04 HM 10500

PENYEBAB : MUNCUL ALARM SERVICE BERKALA

PENYELESAIAN : LAKUKAN PENGGANTIAN OIL MESIN, OLI SWING ,OLI DAMPER CAS. PENGANTIAN
FILTER OLI, FILTER SOLAR, FILTER TANGKI PERNAPASAN ATAU BRIDHER
WO101631PAMNORMAL07/03/2024 10:53:0007/04/2024 10:53:00CLOSE
27
23MECHSERVICE BERKALA DT 06 & 08PAMNORMAL
28
24130409TD00BJA00GP005ELECPENAMBAHAN LAMPU PENERANGAN AREA DOOM SHELTERPERMASALAHAN :
- Proses Loading batubara terhambat

PENYEBAB :
- Tidak ada penerangan diarea doom shelter

PENYELESAIAN :
- Penambahan lampu penerangan @4 x 30 watt
WO101798PAMNORMAL07/03/2024 10:53:0007/04/2024 10:53:00CLOSE
29
25ELECBOILER #1 : INDIKASI KABEL POWER MOTOR SPREADER No.2 UNIT 1 HANGUS"PERMASALAHAN : INDIKASI SPREADER NO 1 DI LOKAL STOP

PENYEBAB : INDIKASI KABEL POWER KE MOTOR HANGUS DAN SHORT

PENYELESAIAN : - LEPAS KABEL POWER KE MOTOR, TES RUNNING INVERTER (OK)
- CONTINUITY KABEL POWER KE MOTOR
- PENYAMBUNGAN DAN REISOLASI KABEL POWER KE MOTOR
WO101629PAMNORMAL05/03/2024 10:53:0005/04/2024 10:53:00CLOSE
30
26130409TD10LAE10AA101I&CBOILER #1 : INSPEKSI PEMBACAAN FLOW TRANSMITTER DESUPERHEATER DI CCR ERRORPERMASALAHAN : PEMBACAAN FLOW DESUPERHEATER #1 ERROR SAAT CONTROL VALVE DI BUKAWO102125PAMNORMAL20/03/2024 10:53:0020/04/2024 10:53:00INPROGRES
31
27130409TD10PGA03AP1105AMECHINSPEKSI CCWP A #1WO101921PAMNORMAL13/03/2024 10:53:0013/04/2024 10:53:00CLOSE
32
28130409TD00EAC01CR100AMECHGEJALA : DRUM CRUSHER SLIP ANTARA MOTOR & DRUM
: INDIKASI BEARING DRUM CRUSHER RUSAK SEHINGGA PUTARAN DRUM CRUSHER BERAT
CHCB : INDIKASI KERUSAKAN BEARING DRUM CRUSHER BAGIAN DEPANWO102098PAMNORMAL14-03-2024 10:1114-04-2024 10:11INPROGRES
33
29I&CBoiler #2 : modul A bag filter indikasi sering berhenti."PERMASALAHAN : modul timer A sering tidak lanjut ke rilay selanjutnya.

PENYEBAB : inidikasi modul timer A berhenti

PENYELESAIAN : - setting timer suwit menjadi 4 jam dari 6 jam, TES RUN modul timer
- CONTINUITY KABEL
WO102100PAMNORMAL14-03-2024 11:4014-04-2024 11:40CLOSE
34
30130409TD10PGA03AP1105AI&CInspeksi PI CCWP A ERRORIndikasi pembacaan PI Over rangeWO102103PAMNORMAL15-03-2024 10:3315-04-2024 10:33CLOSE
35
31MECHPERBAIKAN BAK SCRAPER #2CLOSE
36
32130409TD10HFB10BN001MECHSPREEDER NO 1 INDIKASI V-BELT PUTUS #1WO102104PAMNORMAL15/03/2024 10:33:0015/04/2024 10:33:00CLOSE
37
33common:perbaikan roller return yg patah & penggantian roller cayring line B sisi blakang.
38
34130409TD00QEA02KN4101BMECHINSPEKSI IAC BWO102105PAMNORMAL15-03-2024 10:5015-04-2024 10:50CLOSE
39
35130409TD00QEA01KN4101AMECHINSPEKSI IAC A WO102106PAMNORMAL15-03-2024 11:2915-04-2024 11:29CLOSE
40
36ELECLAMPU TOILET ADMIN LANTAI 2 PADAMPERMASALAHAN : LAMPU TOILET TIDAK BISA MENYALA
PENYEBAB : BOLAM LAMPU PUTUS
PENYELESAIAN : DILAKUKAN PENGGANTIAN BOLAM LAMPU LED 14 V SEBANYAK 1 EA
WO101520PAMNORMAL7-3-2024 14:0007-3-2024 14 30
41
37130409TD20LBA01AA101MECH INSPEKSI KEBOCORAN MOV TURBIN #2WO102121PAMNORMAL19-03-2024 9:2019-04-2024 9:20
42
38130409TD00BJA01GS016I&CPERBAIKAN KEBOCORAN REGULATOR PANEL SWRO WTP 2WO102122PAMNORMAL20-03-2024 9:2020-04-2024 9:20CLOSE
43
39PERBAIKAN KABEL TREY DI AREA TT1PAMNORMAL
44
40130409TD20HFB20AF001MECHPENGGANTIAN V-BELT SCREW FEEDER #2WO102124PAMNORMAL20/03/2024 9:20:0020/04/2024 9:20:00CLOSE
45
41130409TD00PUA01AP0002MECHINSPEKSI CLHORINE PUMP BWO100641PAMNORMALINPROGRES
46
42130409TD20MAA01MT1101BMECHREKOMENDASI OH TEMUAN KEBOCORAN GLAND SEAL BEARAING HP TURBIN #2WO102381PAMOUTAGE26-03-2024 11:1426-04-2024 11:14WAPPR
47
43130409TD00EAC01CR100BMECHLINE TUBING GREASE CRUSHER B BOCORWO102382PAMNORMAL27-03-2024 11:1427-04-2024 11:14INPRG
48
44MECH
49
45MECH1
50
46130409TD10MAV01AN0001I&CPENAMBAHAN PI PADA LINE VAPOR EXRACTION MOT TURBIN #1WO102586PAMNORMAL01-04-2024 16:02
51
47130409TD00BJA00GP011ELECPERBAIKAN LAMPU POS DEPANWO102681PAMNORMAL
52
48130409TD00AYP01FG009I&CPENORMALAN KAMERA CCTV AREA POWER HOUSE TURBIN LANTAI 2Cover kamera cctv power house lt. 2 terlepasWO102848PAMNORMAL
53
49130409TD00VDT006MECHPENORMALAN MASTER DT 06WO102847PAMNORMAL04-04-2024 9:44
54
50130409TD10LCB02AP1101BELECPerbaikan Baut base plate motor CEP B #1WO102850PAMNORMAL
55
51130409TD00VWT001MECHPENORMALAN WATER TRUCK WO102851PAMNORMAL07-04-2024 9:22INPRG
56
52130409TD00VSL001MECH(JASA) PENGGANTIAN BAN SKID LOADER 01WO103051PAMNORMAL16-04-2024 10:33INPRG
57
53MECHPENGGANTIAN CATRIDGE SWRO WTP 2PAMNORMAL
58
54ELECREKOMENDASI VIBRASI MOTOR CEP B #1PERMASALAHAN : REKOMENDASI VIBRASI MOTOR CEP B #1
PENYEBAB : INDIKASI KERUSAKAN PADA BEARING MOTOR DAN BASE PLATE

PENYELESAIAN : - PENGGANTIAN BEARING SISI NDE DAN DE (6311 2Z/C3/6311 2Z/C3)
- DILAKUKAN PENGUJIAN TAHANAN ISOLASI MOTOR
- PENGAMBILAN DATA PADA COVER BEARING MOTOR
WO102102PAMNORMAL02-04-2024 9:30CLOSE
59
55130409TD00VDT009MECHPERBAIKAN DT 09 INDIKASI TIDAK BISA STARTWO103053PAMNORMAL16-04-2024 14:23INPRG
60
56130409TD00EAC01Z100BMECHV-BELT VIBRATING SCREEN LINE B PUTUSWO103150PAMNORMAL17-04-2024 14:23INPRG
61
57130409TD00VDT001MECHPERNORMALAN WATER TRUCK YUNDAIWO103586PAMNORMAL29/04/2024INPRG
62
58130409TD00VWT001MECHPERNORMALAN WATER TRUCK HINOWO103587PAMNORMAL29-04-2024 14:22
63
59I&CPENGGANTIAN FILTER COUNTER FLOW HSDWO103590PAMNORMAL30-04-2024 14:22
WAITING MATERIAL
64
60130409TD00EAC01Z100AMECH
PERBAIKAN VIBRATING SCREEN LINE A DAN PENAMBAHAN BEBAN DI SISI PULLY
WO103761PAMNORMAL02-05-2024 16:42INPRG
65
61130409TD10PAC01AP1142AI&CPENORMALAN PI DAN BLOK VALVE VACUUM PRIMING PUMP ATEMUAN PM: BLOK VALVE PI KOROSIF DAN PATAH
: PEMBACAAN PI INDIKASI ABNORMAL
ACTION : PENGGANTIAN BLOK VALVE
: KALIBRASI PI (HASIL NORMAL)
WO103764PAMNORMAL03-05-2024 16:3203-06-2024 16:32INPRG
66
62130409TD00PAC01AP1141I&CPENORMALAN PI DAN BLOK VALVE VACUUM PRIMING PUMP BTEMUAN PM : BLOK VALVE PI KOROSIF DAN PATAH
: PEMBACAAN PI INDIKASI ABNORMAL
ACTION : PENGGANTIAN BLOK VALVE
: KALIBRASI PI (HASIL NORMAL)
WO103765PAMNORMAL03-05-2024 16:3203-06-2024 16:32INPRG
67
63130409TD20PAC01AP1142AI&CPENORMALAN BLOK VALVE VACUUM PRIMING PUMP CTEMUAN PM : BLOK VALVE PI KOROSIF DAN PATAH
ACTION : PENGGANTIAN BLOK VALVE
WO103766PAMNORMAL03-05-2024 16:3203-06-2024 16:32INPRG
68
64130409TD10LAA01KT1104AI&C
INSPEKSI DAN KALIBRASI CONTROL VALVE EXTRACTION STEAM TO DEAERATOR # 1
TEMUAN PM : DEVIASI PEMBACAAN CONTROL VALVE DI LOKAL DAN CCR
ACTION : DILAKUKAN KALIBRASI (HASIL NORMAL)
WO103767PAMNORMAL03/05/2024 16:32:0003/06/2024 16:32:00INPRG
69
65130409TD10LCC01KC1101AI&C
INSPEKSI DAN PENORMALAN PEMBACAAN LEVEL LPH #2 DI CCR BAD SIGNAL
TEMUAN PM: LEVEL LPH DI CCR BAD SIGNAL
PENYEBAB : KABEL OUTPUT (+) LEVEL TRANSMITTER LEPAS
ACTION : PENGUKURAN TEGANGAN LEVEL TRANSMITTER
: PENORMALAN KABEL LEVEL TRANSMITTER (HASIL NORMAL)
WO103768PAMNORMAL03/05/2024 16:32:0030/05/2024 16:32:00CLOSE
70
66130409TD10PAC01AP1103AMECHCLEANING STRAINER CWP WO103991PAMNORMAL09-05-2024 11:52
71
67130409TD10HNC20AA001I&CInspeksi damper FD Fan #1 error (temuan PM)WO104331PAMNORMAL21-05-2024 13:37CLOSE
72
68130409TD20HCB26AT002MECHPenaplan line sootblower yang kropos G4 boiler #2WO104332PAMNORMAL21/05/2024 13:37:00INPRG
73
69130409TD20HNA40CQ001I&C
Temuan PM: Layar panel oxygen analyzer #2 buram, tidak bisa terpantau di lokal
Permasalahan : Layar panel Oxygen analyzer buram
Dampak : 1. tidak dapat memantau pembacaan oxygen di lokal
2. tidak melakukan setting dan kalibrasi oxygen analyzer
Action : Di buatkan pengajuan panel oxygen analyzer
WO104985PAMNORMAL06-06-2024 15:07
74
70130409TD20ETG10AA101I&C
Temuan PM: Damper air heater sisi atas #2 indikasi fault saat di open dari CCR
Permasalahan : indikasi damper air heater sisi atas #2 fault saat di operasikan
Penyebab : 1. Mekanikal damper berat
2. Indikasi limit switch abnormal
Dampak : Tidak dapat melakukan drain fly ash
Action : Di lakukan inspeksi pada limit switch actuator damper air heater
WO104770PAMNORMAL04-06-2024 9:36
75
71130409TD00GAC05CP001I&CPenggantian PI RO Pump B yang rusak indikasi PI tidak menunjukkan pressure saat pompa RO runingPermasalahan : PI tidak menunjukan tekanan saat pompa RO runing
Action : Kalibrasi PI hasilnya stuck di 5,8 dan tidak bisa naik lagi
- diganti dengan PI yang baru dari gudang (Normal)
WO104986PAMNORMAL06/06/2024
76
72130409TD20CWF01GH001I&CTemuan PM : Filter panel DCS sudah kusut, kotor dan berdebuTemuan PM : Filter panel DCS kusut dan berdebu
Action : - Filter yang lama dicuci untuk spare
- Penggantian filter baru
WO104987PAMNORMAL06/06/2024
77
73130409TD20LCQ10BB001I&C
Temuan PM : Level indicator blowdown tank #2 tidak ada skala pembacaan
Permasalahan : tidak ada skala pembacaan pada level indicator blowdown tank #2
Penyebab : indikasi skala luntur
Akibat : Tidak dapat memantau penunjukan level dengan akurat
Action : Penambahan skala pembacaan pada level indicator
WO104988PAMNORMAL06/06/2024CLOSE
78
74130409TD00SGC01GC002I&CTemuan PM : Alarm gong deluge valve BC02 tidak terpasangPermasalahan : Alarm gong deluge valve BC02 tidak terpasang
Dampak : Alarm gong tidak berfungsi saat ada alarm
Action : pemasangan kembali alarm gong
WO104989PAMNORMAL06/06/2024CLOSE
79
75ELECPENGGANTIAN KONTAKTOR DOSING PUMP BWRO WTP 2WO104772PAMNORMAL05-06-2024 10:53INPRG
80
76MECHTerdapat rantai excavator no 03 kendorWO104984PAMNORMAL06-06-2024 10:53WMATL
81
77130409TD00EAC02BC04MECHPenggantian rooler retrun BC02 Line BWO104991PAMNORMAL10/06/2024CLOSE
82
78130409TD20ETA10AF001MECHPenggantian rooler retrun Ash cooler #2WO104996PAMNORMAL11-06-2024 10:28CLOSE
83
79130409TD20HFB30AF001MECHSpiral screw 3 #2 patahWO104999PAMNORMAL
84
80130409TD00EAC01BC05ELECPembuatan kabel tray area TT1WO105001PAMNORMALCLOSE
85
81130409TD00BFA01GS023MECHPEMASANGAN DOSING PUMP PHOSPATEWO105002PAMNORMAL
86
82130409TD00QSC01AT002MECHCLEANING PURIFIER 2WO105316PAMNORMALCLOSE
87
83130409TD00EAC01BN100MECHPEMBUATAN PIJAKAN DI AREA KABEL TRAY UNDERGROUNDWO105541PAMNORMAL19-06-2024 15:3819-07-2024 15:38CLOSE
88
84130409TD20PAC02AP1103DMECHPENAMBAHAN GLAND PACKING CWP DWO105542PAMNORMAL19-06-2024 15:3819-07-2024 15:38CLOSE
89
85130409TD10MKA01AG0001ELECPENGGANTIAN CARBON BRUSH GENERATOR #1WO105543PAMNORMAL19-06-2024 15:5119-07-2024 15:51CLOSE
90
87130409TD20HNC20AA001I&CPenggantian Dumper ID fan #2 AI 2023WO105547PAMNORMAL20/06/2024 10:39:00OUTAGE
91
88130409TD10MAV12AT001I&CPemasangan DP pada Line Lube Oil #1 WO105548PAMNORMAL20/06/2024 10:39:00OUTAGE
92
89130409TD20MAV12AT001I&CPemasangan DP pada Line Lube Oil #2WO105549PAMNORMAL20/06/2024 10:39:00OUTAGE
93
90130409TD00QEA03KN4101CMECHIAC C trip indikasi High Disch Temperatur.WO105554PAMNORMAL24-06-2024 10:38
94
91130409TD20ETA10AF001MECHPERBAIKAN SPROKET ASH COOLER #2WO105562PAMNORMAL21-06-2024 10:38inprogres
95
92130409TD00GAF02AP1115BMECHPENGGATIAN COUPLING POMPA DAN MOTOR RO PUMP BWO105556PAMNORMAL17-06-2024 14:49WMATL
96
93130409TD00EAC01CR100AMECHInspeksi dan penormalan Crusher AWO105728PAMNORMAL27-06-2024 10:29inprogres
97
94130409TD00SGA01AZ018ELECPERBAIKAN STOP KONTAK DI RUANGAN RENDAL OPSWO105735PAMNORMAL01/07/2024 10:29:00inprogres
98
95130409TD00EGB07BB001I&CPEMASANGAN VALVE DRAIN COUNTER FLOW HSDWO106079PAMNORMAL
99
96130409TD00GCB01AT002MECHPENGGANTIAN CADRITGE SWRO 2WO106080PAMNORMAL
100
97130409TD00UMZ01BQ004MECHPerbaikan support tangki Clhorine indikasi keroposWO106083PAMNORMAL01/07/2024 10:29:00