ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Solar Powered System Estimator v2.4
2
By Doug Hanson
3
See the Solar Powered System Estimator - User’s Guide v1.1 for use with Estimator v2.4 HERE
4
For solar, wind, or solar/wind hybrid renewable power, determining the most appropriate, efficient, and cost-effective system requires a comprehensive installation electrical load analysis to determine the desired system capacity. Portions of this spreadsheet are useful for all projects.
5
This spreadsheet will help to estimate the size, quantity, and parameters of solar system components given specified
loads, component efficiencies, and environmental conditions.
6
Fill in the yellow cells for each step. Numbers shown in yellow squares now are just examples.
7
8
Project Name:Latch Key "Boombox" Sound Stage
9
10
Step 1: Loads - List ALL the loads that will need to be powered.
11
This section is divided into loads that will use your system battery voltage, loads that use a different DC voltage, and AC loads.
12
You will also be asked for converter and inverter efficiencies where required.
13
14
Uses System Battery Voltage: (typically 12, 24, 48 volts, etc.)44.8volts
15
16
fill in one of these columns onlyonly one of these
17
Qty of loadsDescription of loadname plate wattsOR name plate VAOR name plate AmpsOR measured powerload power (calculated)hours/ dayor duty cycle (%)daily energy (watt-hours)
18
None0.00.0
19
The EXM ProSUB uses four 97.7 Wh battery packs in a series/parallel configuration. Each individual pack is 24V, giving a 48V battery system after the series/parallel configuration.
0.00.0
20
0.00.0
21
The EXM Pro10 uses a single 48V battery pack rated at approximately 230 Wh.
0.00.0
22
I will just add that power consumption while charging is 48W for EXM Pro10 and 150W for EXM ProSub . These systems run only on battery power, they do not run on AC, so these specs are all you need.
0.00.0
23
0.00.0
24
0.00.0
25
0.00.0
26
0.00.0
27
0.00.0
28
0.00.0
29
0.00.0
30
31
Daily Energy used by system battery voltage loads:0.00
32
33
Uses Non-battery voltage DC loads: (e.g., 5 volts)5volts
34
35
fill in one of these columns onlyonly one of these
36
Qty of loadsDescription of loadname plate wattsOR name plate VAOR name plate AmpsOR measured powerload power (calculated)hours/ dayor duty cycle (%)daily energy (watt-hours)
37
None00.0
38
00.0
39
00.0
40
00.0
41
00.0
42
00.0
43
00.0
44
00.0
45
00.0
46
00.0
47
00.0
48
00.0
49
50
Daily Energy used by non-battery voltage DC loads:0.0
51
DC-DC converter efficiency (%):90%
52
Adjusted Energy used by non-battery voltage DC loads:0.0
53
54
Uses AC loads (e.g., 120 volts)120volts
55
56
fill in one of these columns onlyonly one of these
57
Qty of loadsDescription of loadname plate wattsOR name plate VAOR name plate AmpsOR measured powerload power (calculated)hours/ dayor duty cycle (%)daily energy (watt-hours)
58
1Pioneer XDJ-AZ Controller60.0605300
59
2Yorkville EXM Pro10 -INTERNAL BATTERY300.060053,000
60
2Yorkville EXM Pro Sub - INTERNAL BATTERY500.01,00055,000
61
00
62
00
63
00
64
00
65
00
66
00
67
00
68
00
69
00
70
71
Daily Energy used by AC loads:8,300.00
72
Inverter efficiency (%):90.00%
73
Adjusted Energy used by AC loads:9,222.22
74
75
Step 2: Margins -
76
This section will add any margins if desired
77
78
Total of all loads from Step 1: ------->Daily energy-->9,222watt-hours9kW-hours
79
Reserve Days (0.0 - N) --->1.018,444watt-hours18kW-hours
80
Weather margin in days (see note 1):1.036,889watt-hours37kW-hours<---Note 1: Bad weather can affect the amount of solar power collected and stored in batteries. Enter the number of EXTRA days between 0 and N days (e.g., 0.5)
81
82
83
84
Step 3: Batteries -
Note: A battery is taken to be the aggregation of cells that you choose to make up the system voltage. The Ah rating is for one unit of this configuration.
85
This section will estimate the storage batteries required
86
87
Battery TypeSelect TypeAmp-hour ratingAvailable Capacity %Usable Capacity (Ah)Qty batteries at system voltage
88
Deep Cycle Lead Acid (PB)0.000.000.00
89
Lithium Ion (LiIon)0.000.000.00
90
Lithium Ferrous Phosphate (LiFePo4)Jackery Explorer 2000 V245.5895.004,330.130.19
91
92
Step 4: Panels -
93
This section will estimate the number of solar panels required
94
95
Panel TypePanel Power (watts)Daylight Charge HoursPanel EfficiencyCharger EfficiencyBattery Charge EfficiencyQty panels
96
Monocyrstaline 120.006.0025.0075.0090.000.00030
97
98
Step 5: Charge Controller -
99
This section will estimate the size of the charge controller
100