| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Solar Powered System Estimator v2.4 | |||||||||||||||||||||||||
2 | By Doug Hanson | |||||||||||||||||||||||||
3 | See the Solar Powered System Estimator - User’s Guide v1.1 for use with Estimator v2.4 HERE | |||||||||||||||||||||||||
4 | For solar, wind, or solar/wind hybrid renewable power, determining the most appropriate, efficient, and cost-effective system requires a comprehensive installation electrical load analysis to determine the desired system capacity. Portions of this spreadsheet are useful for all projects. | |||||||||||||||||||||||||
5 | This spreadsheet will help to estimate the size, quantity, and parameters of solar system components given specified loads, component efficiencies, and environmental conditions. | |||||||||||||||||||||||||
6 | Fill in the yellow cells for each step. Numbers shown in yellow squares now are just examples. | |||||||||||||||||||||||||
7 | ||||||||||||||||||||||||||
8 | Project Name: | Latch Key "Boombox" Sound Stage | ||||||||||||||||||||||||
9 | ||||||||||||||||||||||||||
10 | Step 1: Loads - List ALL the loads that will need to be powered. | |||||||||||||||||||||||||
11 | This section is divided into loads that will use your system battery voltage, loads that use a different DC voltage, and AC loads. | |||||||||||||||||||||||||
12 | You will also be asked for converter and inverter efficiencies where required. | |||||||||||||||||||||||||
13 | ||||||||||||||||||||||||||
14 | Uses System Battery Voltage: (typically 12, 24, 48 volts, etc.) | 44.8 | volts | |||||||||||||||||||||||
15 | ||||||||||||||||||||||||||
16 | fill in one of these columns only | only one of these | ||||||||||||||||||||||||
17 | Qty of loads | Description of load | name plate watts | OR name plate VA | OR name plate Amps | OR measured power | load power (calculated) | hours/ day | or duty cycle (%) | daily energy (watt-hours) | ||||||||||||||||
18 | None | 0.0 | 0.0 | |||||||||||||||||||||||
19 | The EXM ProSUB uses four 97.7 Wh battery packs in a series/parallel configuration. Each individual pack is 24V, giving a 48V battery system after the series/parallel configuration. | 0.0 | 0.0 | |||||||||||||||||||||||
20 | 0.0 | 0.0 | ||||||||||||||||||||||||
21 | The EXM Pro10 uses a single 48V battery pack rated at approximately 230 Wh. | 0.0 | 0.0 | |||||||||||||||||||||||
22 | I will just add that power consumption while charging is 48W for EXM Pro10 and 150W for EXM ProSub . These systems run only on battery power, they do not run on AC, so these specs are all you need. | 0.0 | 0.0 | |||||||||||||||||||||||
23 | 0.0 | 0.0 | ||||||||||||||||||||||||
24 | 0.0 | 0.0 | ||||||||||||||||||||||||
25 | 0.0 | 0.0 | ||||||||||||||||||||||||
26 | 0.0 | 0.0 | ||||||||||||||||||||||||
27 | 0.0 | 0.0 | ||||||||||||||||||||||||
28 | 0.0 | 0.0 | ||||||||||||||||||||||||
29 | 0.0 | 0.0 | ||||||||||||||||||||||||
30 | ||||||||||||||||||||||||||
31 | Daily Energy used by system battery voltage loads: | 0.00 | ||||||||||||||||||||||||
32 | ||||||||||||||||||||||||||
33 | Uses Non-battery voltage DC loads: (e.g., 5 volts) | 5 | volts | |||||||||||||||||||||||
34 | ||||||||||||||||||||||||||
35 | fill in one of these columns only | only one of these | ||||||||||||||||||||||||
36 | Qty of loads | Description of load | name plate watts | OR name plate VA | OR name plate Amps | OR measured power | load power (calculated) | hours/ day | or duty cycle (%) | daily energy (watt-hours) | ||||||||||||||||
37 | None | 0 | 0.0 | |||||||||||||||||||||||
38 | 0 | 0.0 | ||||||||||||||||||||||||
39 | 0 | 0.0 | ||||||||||||||||||||||||
40 | 0 | 0.0 | ||||||||||||||||||||||||
41 | 0 | 0.0 | ||||||||||||||||||||||||
42 | 0 | 0.0 | ||||||||||||||||||||||||
43 | 0 | 0.0 | ||||||||||||||||||||||||
44 | 0 | 0.0 | ||||||||||||||||||||||||
45 | 0 | 0.0 | ||||||||||||||||||||||||
46 | 0 | 0.0 | ||||||||||||||||||||||||
47 | 0 | 0.0 | ||||||||||||||||||||||||
48 | 0 | 0.0 | ||||||||||||||||||||||||
49 | ||||||||||||||||||||||||||
50 | Daily Energy used by non-battery voltage DC loads: | 0.0 | ||||||||||||||||||||||||
51 | DC-DC converter efficiency (%): | 90% | ||||||||||||||||||||||||
52 | Adjusted Energy used by non-battery voltage DC loads: | 0.0 | ||||||||||||||||||||||||
53 | ||||||||||||||||||||||||||
54 | Uses AC loads (e.g., 120 volts) | 120 | volts | |||||||||||||||||||||||
55 | ||||||||||||||||||||||||||
56 | fill in one of these columns only | only one of these | ||||||||||||||||||||||||
57 | Qty of loads | Description of load | name plate watts | OR name plate VA | OR name plate Amps | OR measured power | load power (calculated) | hours/ day | or duty cycle (%) | daily energy (watt-hours) | ||||||||||||||||
58 | 1 | Pioneer XDJ-AZ Controller | 60.0 | 60 | 5 | 300 | ||||||||||||||||||||
59 | 2 | Yorkville EXM Pro10 -INTERNAL BATTERY | 300.0 | 600 | 5 | 3,000 | ||||||||||||||||||||
60 | 2 | Yorkville EXM Pro Sub - INTERNAL BATTERY | 500.0 | 1,000 | 5 | 5,000 | ||||||||||||||||||||
61 | 0 | 0 | ||||||||||||||||||||||||
62 | 0 | 0 | ||||||||||||||||||||||||
63 | 0 | 0 | ||||||||||||||||||||||||
64 | 0 | 0 | ||||||||||||||||||||||||
65 | 0 | 0 | ||||||||||||||||||||||||
66 | 0 | 0 | ||||||||||||||||||||||||
67 | 0 | 0 | ||||||||||||||||||||||||
68 | 0 | 0 | ||||||||||||||||||||||||
69 | 0 | 0 | ||||||||||||||||||||||||
70 | ||||||||||||||||||||||||||
71 | Daily Energy used by AC loads: | 8,300.00 | ||||||||||||||||||||||||
72 | Inverter efficiency (%): | 90.00% | ||||||||||||||||||||||||
73 | Adjusted Energy used by AC loads: | 9,222.22 | ||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | Step 2: Margins - | |||||||||||||||||||||||||
76 | This section will add any margins if desired | |||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | Total of all loads from Step 1: -------> | Daily energy--> | 9,222 | watt-hours | 9 | kW-hours | ||||||||||||||||||||
79 | Reserve Days (0.0 - N) ---> | 1.0 | 18,444 | watt-hours | 18 | kW-hours | ||||||||||||||||||||
80 | Weather margin in days (see note 1): | 1.0 | 36,889 | watt-hours | 37 | kW-hours | <---Note 1: Bad weather can affect the amount of solar power collected and stored in batteries. Enter the number of EXTRA days between 0 and N days (e.g., 0.5) | |||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | Step 3: Batteries - | Note: A battery is taken to be the aggregation of cells that you choose to make up the system voltage. The Ah rating is for one unit of this configuration. | ||||||||||||||||||||||||
85 | This section will estimate the storage batteries required | |||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | Battery Type | Select Type | Amp-hour rating | Available Capacity % | Usable Capacity (Ah) | Qty batteries at system voltage | ||||||||||||||||||||
88 | Deep Cycle Lead Acid (PB) | 0.00 | 0.00 | 0.00 | ||||||||||||||||||||||
89 | Lithium Ion (LiIon) | 0.00 | 0.00 | 0.00 | ||||||||||||||||||||||
90 | Lithium Ferrous Phosphate (LiFePo4) | Jackery Explorer 2000 V2 | 45.58 | 95.00 | 4,330.13 | 0.19 | ||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | Step 4: Panels - | |||||||||||||||||||||||||
93 | This section will estimate the number of solar panels required | |||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | Panel Type | Panel Power (watts) | Daylight Charge Hours | Panel Efficiency | Charger Efficiency | Battery Charge Efficiency | Qty panels | |||||||||||||||||||
96 | Monocyrstaline | 120.00 | 6.00 | 25.00 | 75.00 | 90.00 | 0.00030 | |||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | Step 5: Charge Controller - | |||||||||||||||||||||||||
99 | This section will estimate the size of the charge controller | |||||||||||||||||||||||||
100 | ||||||||||||||||||||||||||