ABCDEFGHIJKLMNOPQRSTUVWXYZAAABACADAE
1
SCC
E_POLLUTANT_CD
POLLUTANT_DESC
POLLUTANT_CATG_NAME
E_EMIS_CALC_MTHD_CD
EMIS_CALC_MTHD_DESC
E_EMIS_FCTR_NM_UOM_CD
E_EMIS_FCTR_DN_UOM_CD
E_CALC_MTRL_TYPE_CD
CALC_MTRL_TYPE_DESC
E_CALC_PARM_TYPE_CD
IS_EMIS_FCTR_FORMULA_IND
EMIS_FCTR
EMIS_FCTR_FORMULA
E_CTRL_MEAS_CD
CTRL_MEAS_DESC
E_CTRL_MEAS_CD_2
CTRL_MEAS_DESC_2
EMIS_FCTR_DESC
EMIS_FCTR_NOTE
EMIS_FCTR_SRC
EMIS_FCTR_IDEN
EF_LAST_INV_YEAR
AGNCY_POLL_LAST_INV_YEAR
SCC_LAST_INV_YEAR
PRIORITY_ORDER
EF_CREATED_DATE
LAST_UPDATED_DATE
2
(All SCCs)3_1
Material Balance (post-control EF)
LB1
DEN*(VOC/100)
3_143059.563643059.5636
3
(All SCCs)3_2
Material Balance (pre-control EF)
LB1
DEN*(VOC/100)
3_243059.563643059.5636
4
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler7439921Lead
Lead Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.00890
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
WebFIRE (ID:5)
51004327043270
5
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler7782492Selenium
Selenium Compounds
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.00074046128
Electrostatic Precipitator - Dry (DESP)
Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295.
Based on reported emissions data and engineering judgement. Lack of Supporting Documentation.
WebFIRE (ID:19)
192004327043270
6
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerCO
Carbon Monoxide
Carbon Monoxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.60
Uncontrolled
This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee
WebFIRE (ID:4)
41004327043270
7
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerNH3AmmoniaAmmonia8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0005650
Uncontrolled
(AP42 Text: Section 1.2) Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:1)
11003677043270
8
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerNH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.63107
Selective Noncatalytic Reduction for NOx
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:2)
22003677043270
9
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerNH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.31139
Selective Catalytic Reduction (SCR)
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:3)
32003677043270
10
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerNOX
Nitrogen Oxides
Nitrogen Oxides
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I0180
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
WebFIRE (ID:6)
61004327043270
11
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM-CON
PM Condensible
PM Condensible
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I1
((0.1*SU)-0.03)*24.6
0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g
WebFIRE (ID:7)
73003801843270
12
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I1
((0.1*SU)-0.03)*24.6
121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g
WebFIRE (ID:9)
94003801843270
13
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I1
((0.1*SU)-0.03)*24.6
100Baghouse
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g
WebFIRE (ID:8)
84003801843270
14
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM10-FIL
PM10 Filterable
PM10 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I12.3*A0
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A=% Ash content.
WebFIRE (ID:13)
133004327043270
15
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I10.11*A121
Cyclones (Multiple)
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A=% Ash content.
WebFIRE (ID:15)
154004327043270
16
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I10.013*A100Baghouse
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A=% Ash content.
WebFIRE (ID:14)
144004327043270
17
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I10.11*A121
Cyclones (Multiple)
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A=% Ash content.
WebFIRE (ID:15)
SLEIS2535918
19004004311843118
18
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I10.6*A0
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:16)
163003649443270
19
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I10.48*A121
Cyclones (Multiple)
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:18)
184003649443270
20
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerPM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I10.006*A100Baghouse
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:17)
174003649443270
21
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerSO2
Sulfur Dioxide
Sulfur Dioxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I139*SU0
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
To determine EF in lb/ton, multiply the EF provided by the weight percent sulfur. S=% Sulfur content.
WebFIRE (ID:20)
203004327043270
22
10100101External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: BoilerVOC
Volatile Organic Compounds
Volatile Organic Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.070
Uncontrolled
This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee
WebFIRE (ID:21)
211004327043270
23
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7439921Lead
Lead Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.00890
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
WebFIRE (ID:32)
321004327043270
24
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7439965
Manganese
Manganese Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.00360
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:33)
331004327043270
25
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7439976Mercury
Mercury Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.000130
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:34)
341004327043270
26
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7440020Nickel
Nickel Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0260
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:36)
361004327043270
27
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7440382Arsenic
Arsenic Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.000190
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:25)
251004327043270
28
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7440417Beryllium
Beryllium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.000310
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:26)
261004327043270
29
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7440439Cadmium
Cadmium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0000710
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:28)
281004327043270
30
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7440473Chromium
Chromium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0280
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:31)
311004327043270
31
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7782492Selenium
Selenium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.00130
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:46)
461004327043270
32
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker7782492Selenium
Selenium Compounds
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.00205902121
Cyclones (Multiple)
Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295.
Based on reported emissions data and engineering judgement. Lack of Supporting Documentation.
WebFIRE (ID:47)
472004327043270
33
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker85018
Phenanthrene
Polycyclic Organic Matter
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.00680
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:38)
3819001004327043270
34
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker91203
Naphthalene
Naphthalene
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.130
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:35)
351004327043270
35
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker92524BiphenylBiphenyl8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0250
Uncontrolled
(AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and
WebFIRE (ID:27)
271004327043270
36
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerCO
Carbon Monoxide
Carbon Monoxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.60
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
WebFIRE (ID:30)
301004327043270
37
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerNH3AmmoniaAmmonia8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.0005650
Uncontrolled
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:22)
221003677043270
38
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerNH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.63107
Selective Noncatalytic Reduction for NOx
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:23)
232003677043270
39
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerNH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON640
Anthracite
I00.31139
Selective Catalytic Reduction (SCR)
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:24)
242003677043270
40
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerNOX
Nitrogen Oxides
Nitrogen Oxides
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I090
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
WebFIRE (ID:37)
371004327043270
41
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerPM-CON
PM Condensible
PM Condensible
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I10.08*A0
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
Multiply the emission factor provided by the weight % ash content of the fuel to obtain the emission factor in lb/ton. Emission factor is for condensible PM. A=% Ash content.
WebFIRE (ID:39)
393004327043270
42
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerPM10-FIL
PM10 Filterable
PM10 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I04.80
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
from figure 1.2-2 of section 1.2 AP-42.
WebFIRE (ID:42)
421004327043270
43
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerPM10-PRI
PM10 Primary (Filt + Cond)
PM10 Primary (Filt + Cond)
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I1
(4.8)+(0.08*A)
0
Uncontrolled
This emission factor was derived from other particulate matter emission factors. See Notes.
Sum of PM10-FIL and PM-CON emission factors
WebFIRE (ID:43)
433003801843270
44
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerPM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I02.50
Uncontrolled
PM Calculator.
Derived factor: 52% of uncontrolled PM10-FIL factor. Fraction of PM10-FIL to PM-FIL is 0.52; PM25-FIL to PM-FIL is 0.27. These fractions are from the PM Calculator. The reference for the fractions is unknown.
WebFIRE (ID:44)
441003801843270
45
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerPM25-PRI
PM2.5 Primary (Filt + Cond)
PM2.5 Primary (Filt + Cond)
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I1
(2.5)+(0.08*A)
0
Uncontrolled
This emission factor was derived from other particulate matter emission factors. See Notes.
Sum of PM25-FIL and PM-CON emission factors
WebFIRE (ID:45)
453003801843270
46
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerSO2
Sulfur Dioxide
Sulfur Dioxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I139*SU0
Uncontrolled
(AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard
To determine EF in lb/ton, multiply the EF provided by the weight percent sulfur. S=% Sulfur content.
WebFIRE (ID:48)
483004327043270
47
10100102External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) StokerVOC
Volatile Organic Compounds
Volatile Organic Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON640
Anthracite
I00.070
Uncontrolled
This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee
WebFIRE (ID:51)
511004327043270
48
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
206440
Fluoranthene
Polycyclic Organic Matter
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0001696001870
Uncontrolled
Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra
110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation.
WebFIRE (ID:62)
6219001004327043270
49
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
218019Chrysene
Polycyclic Organic Matter
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.00021600023810
Uncontrolled
Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra
110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation.
WebFIRE (ID:61)
6119001004327043270
50
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
246
Polycyclic Organic Matter
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.00023114128
Electrostatic Precipitator - Dry (DESP)
Composite. Radian FIRE database 1994 release.
Represents both gaseous and particulate POM. Average emission factor from reported values. Lack of Supporting Documentation.
WebFIRE (ID:105)
1052004327043270
51
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
246
Polycyclic Organic Matter
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.0146642
Wet Scrubber - Medium Efficiency
EPA. May 1988. In: Locating and Estimating Air Emissions from Sources of Polycyclic Organic Matter (POM). EPA-450/4-84-007p. U.S. Environmental Protection Agency. Research Triangle Park, North Carolina.
Represents both gaseous and particulate POM. Lack of Supporting Documentation.
WebFIRE (ID:104)
1042004327043270
52
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
50328
Benzo[a]Pyrene
Polycyclic Organic Matter
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.00019440021430
Uncontrolled
Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra
110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation.
WebFIRE (ID:56)
5619001004327043270
53
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7439921Lead
Lead Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0131820
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
WebFIRE (ID:66)
661003603943270
54
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7439921Lead
Lead Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.01330
Uncontrolled
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Based on literature review.
WebFIRE (ID:65)
6519981004327043270
55
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7439965
Manganese
Manganese Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0492440
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:67)
671004327043270
56
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7439976Mercury
Mercury Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0004160
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:68)
681004327043270
57
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7440020Nickel
Nickel Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.027690
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:70)
701004327043270
58
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7440382Arsenic
Arsenic Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0139880
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:55)
551004327043270
59
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7440417Beryllium
Beryllium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0021060
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:57)
571004327043270
60
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7440439Cadmium
Cadmium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0014820
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:58)
581004327043270
61
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7440473Chromium
Chromium Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.033670
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Based on literature review.
WebFIRE (ID:60)
601004327043270
62
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7647010
Hydrochloric Acid
Hydrochloric Acid
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I01.20
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
WebFIRE (ID:63)
631004327043270
63
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7664393
Hydrogen Fluoride
Hydrogen Fluoride
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.150
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
WebFIRE (ID:64)
641004327043270
64
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
7782492Selenium
Selenium Compounds
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.0006318128
Electrostatic Precipitator - Dry (DESP)
Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295.
Based on reported emissions data and engineering judgement. Lack of Supporting Documentation.
WebFIRE (ID:106)
1062004327043270
65
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
CO
Carbon Monoxide
Carbon Monoxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.50
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Values of 1 or 2 orders of magnitude higher can occur when combustion is not complete. Emission factors for CO2 emissions from coal combustion should be calculated using CO2/ton coal = 73.3C, where C is the wt. percent carbon content of the coal.
WebFIRE (ID:59)
591004327043270
66
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
NH3AmmoniaAmmonia8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.0005650
Uncontrolled
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:52)
521003677043270
67
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
NH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.63107
Selective Noncatalytic Reduction for NOx
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:53)
532003677043270
68
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
NH3AmmoniaAmmonia8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.31139
Selective Catalytic Reduction (SCR)
Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994.
WebFIRE (ID:54)
542003677043270
69
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
NOX
Nitrogen Oxides
Nitrogen Oxides
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I0340
Uncontrolled
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Expressed as NO2. Generally, 95+ volume % of nitrogen oxides present in combustion exhaust will be in the form of NO, the rest NO2. To express factors as NO, multiply factors by 0.66.
WebFIRE (ID:71)
7119981004327043270
70
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
NOX
Nitrogen Oxides
Nitrogen Oxides
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I0310
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Expressed as NO2.
WebFIRE (ID:72)
721003603943270
71
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.5299
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
(Duplicate Reason: With flue gas desulfurization controls.) Factor is for pulverized coal-fired boilers with all PM controls (with flue gas desulfurization controls).
WebFIRE (ID:77)
772003603943270
72
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM-CON
PM Condensible
PM Condensible
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I1
((0.1*SU)-0.03)*26
0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt
WebFIRE (ID:75)
753003801843270
73
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I1
((0.1*SU)-0.03)*26
121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt
WebFIRE (ID:78)
784003801843270
74
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I1
((0.1*SU)-0.03)*26
99
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
(Duplicate Reason: Without flue gas desulfurization controls.) Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton os subbituminous coal, multiply by 20 M
WebFIRE (ID:76)
764003603943270
75
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM-CON
PM Condensible
PM Condensible
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I1
((0.1*SU)-0.03)*26
128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt
WebFIRE (ID:79)
794003801843270
76
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-FIL
PM10 Filterable
PM10 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I12.6*A0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Multiply the emission factor provided by the weight percent ash content of the coal to obtain lb/ton EF. A=% Ash content.
WebFIRE (ID:90)
903004327043270
77
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.042*A128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF.
WebFIRE (ID:94)
944003649543270
78
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.042*A128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF.
WebFIRE (ID:93)
9319984004327043270
79
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I11.3*A121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF.
WebFIRE (ID:91)
9119984004327043270
80
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-FIL
PM10 Filterable
PM10 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I11.3*A121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF.
WebFIRE (ID:92)
924003649543270
81
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-PRI
PM10 Primary (Filt + Cond)
PM10 Primary (Filt + Cond)
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I12.6*A0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
WebFIRE (ID:95)
9519993003603943270
82
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-PRI
PM10 Primary (Filt + Cond)
PM10 Primary (Filt + Cond)
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I11.3*A121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Multiple cyclone estimated control efficiency = 94%
WebFIRE (ID:96)
9619994003603943270
83
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM10-PRI
PM10 Primary (Filt + Cond)
PM10 Primary (Filt + Cond)
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.042*A128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP estimated control efficiency = 99.2%
WebFIRE (ID:97)
9719994003603943270
84
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I11.48*A0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:98)
983003649543270
85
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.86*A121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Multiple cyclone estimated control efficiency = 94%. A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:99)
994003649543270
86
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-FIL
PM2.5 Filterable
PM2.5 Filterable
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.022*A128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP estimated control efficiency = 99.2%. A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2.
WebFIRE (ID:100)
1004003649543270
87
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-PRI
PM2.5 Primary (Filt + Cond)
PM2.5 Primary (Filt + Cond)
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I11.48*A0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
WebFIRE (ID:101)
10119993003603943270
88
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-PRI
PM2.5 Primary (Filt + Cond)
PM2.5 Primary (Filt + Cond)
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.86*A121
Cyclones (Multiple)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Multiple cyclone estimated control efficiency = 94%
WebFIRE (ID:102)
10219994003603943270
89
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
PM25-PRI
PM2.5 Primary (Filt + Cond)
PM2.5 Primary (Filt + Cond)
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I10.022*A128
Electrostatic Precipitator - Dry (DESP)
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP estimated control efficiency = 99.2%
WebFIRE (ID:103)
10319994003603943270
90
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
SO2
Sulfur Dioxide
Sulfur Dioxide
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I138*SU0
Uncontrolled
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
Expressed as SO2, including SO2, SO3, and gaseous sulfates. Multiply the emission factor provided by the wt. % sulfur content of the fuel to obtain emission factor in lb/activity units. S=% Sulfur content.
WebFIRE (ID:107)
1073004327043270
91
10100201
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom
VOC
Volatile Organic Compounds
Volatile Organic Compounds
8_2
EPA WebFIRE Emission Factor (pre-control)
LBTON663
Bituminous Coal
I00.040
Uncontrolled
(AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla
Nominal values achievable under normal operating conditions. Values one or two orders of magnitude higher can occur when combustion is not complete.
WebFIRE (ID:109)
10919981004327043270
92
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
100414
Ethyl Benzene
Ethylbenzene
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.00009499
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:151)
1512004327043270
93
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
100425StyreneStyrene8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.00002599
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:283)
2962004327043270
94
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
100447
Benzyl Chloride
Benzyl Chloride
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.000799
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:127)
1272004327043270
95
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
106934
Ethylene Dibromide
Ethylene Dibromide
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.000001299
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:152)
1522004327043270
96
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
107028AcroleinAcrolein8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.0002999
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:114)
1142004327043270
97
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
107062
Ethylene Dichloride
Ethylene Dichloride
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.0000499
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:153)
1532004327043270
98
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
108054
Vinyl Acetate
Vinyl Acetate
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.000007699
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:300)
3152004327043270
99
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
108883TolueneToluene8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.0002499
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:297)
3122004327043270
100
10100202
External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom
108907
Chlorobenzene
Chlorobenzene
8_1
EPA WebFIRE Emission Factor (post-control)
LBTON663
Bituminous Coal
I00.00002299
Other Control Device
(AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency,
ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER
WebFIRE (ID:138)
1382004327043270