| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | AA | AB | AC | AD | AE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | SCC | E_POLLUTANT_CD | POLLUTANT_DESC | POLLUTANT_CATG_NAME | E_EMIS_CALC_MTHD_CD | EMIS_CALC_MTHD_DESC | E_EMIS_FCTR_NM_UOM_CD | E_EMIS_FCTR_DN_UOM_CD | E_CALC_MTRL_TYPE_CD | CALC_MTRL_TYPE_DESC | E_CALC_PARM_TYPE_CD | IS_EMIS_FCTR_FORMULA_IND | EMIS_FCTR | EMIS_FCTR_FORMULA | E_CTRL_MEAS_CD | CTRL_MEAS_DESC | E_CTRL_MEAS_CD_2 | CTRL_MEAS_DESC_2 | EMIS_FCTR_DESC | EMIS_FCTR_NOTE | EMIS_FCTR_SRC | EMIS_FCTR_IDEN | EF_LAST_INV_YEAR | AGNCY_POLL_LAST_INV_YEAR | SCC_LAST_INV_YEAR | PRIORITY_ORDER | EF_CREATED_DATE | LAST_UPDATED_DATE | |||
2 | (All SCCs) | 3_1 | Material Balance (post-control EF) | LB | 1 | DEN*(VOC/100) | 3_1 | 43059.5636 | 43059.5636 | ||||||||||||||||||||||
3 | (All SCCs) | 3_2 | Material Balance (pre-control EF) | LB | 1 | DEN*(VOC/100) | 3_2 | 43059.5636 | 43059.5636 | ||||||||||||||||||||||
4 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | 7439921 | Lead | Lead Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.0089 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | WebFIRE (ID:5) | 5 | 100 | 43270 | 43270 | |||||||||
5 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | 7782492 | Selenium | Selenium Compounds | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.00074046 | 128 | Electrostatic Precipitator - Dry (DESP) | Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295. | Based on reported emissions data and engineering judgement. Lack of Supporting Documentation. | WebFIRE (ID:19) | 19 | 200 | 43270 | 43270 | ||||||||
6 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | CO | Carbon Monoxide | Carbon Monoxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.6 | 0 | Uncontrolled | This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee | WebFIRE (ID:4) | 4 | 100 | 43270 | 43270 | |||||||||
7 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | NH3 | Ammonia | Ammonia | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.000565 | 0 | Uncontrolled | (AP42 Text: Section 1.2) Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:1) | 1 | 100 | 36770 | 43270 | |||||||||
8 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.63 | 107 | Selective Noncatalytic Reduction for NOx | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:2) | 2 | 200 | 36770 | 43270 | |||||||||
9 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.31 | 139 | Selective Catalytic Reduction (SCR) | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:3) | 3 | 200 | 36770 | 43270 | |||||||||
10 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | NOX | Nitrogen Oxides | Nitrogen Oxides | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 18 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | WebFIRE (ID:6) | 6 | 100 | 43270 | 43270 | |||||||||
11 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM-CON | PM Condensible | PM Condensible | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | ((0.1*SU)-0.03)*24.6 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g | WebFIRE (ID:7) | 7 | 300 | 38018 | 43270 | ||||||||
12 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | ((0.1*SU)-0.03)*24.6 | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g | WebFIRE (ID:9) | 9 | 400 | 38018 | 43270 | ||||||||
13 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | ((0.1*SU)-0.03)*24.6 | 100 | Baghouse | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue g | WebFIRE (ID:8) | 8 | 400 | 38018 | 43270 | ||||||||
14 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | 2.3*A | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A=% Ash content. | WebFIRE (ID:13) | 13 | 300 | 43270 | 43270 | ||||||||
15 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | 0.11*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A=% Ash content. | WebFIRE (ID:15) | 15 | 400 | 43270 | 43270 | ||||||||
16 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | 0.013*A | 100 | Baghouse | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A=% Ash content. | WebFIRE (ID:14) | 14 | 400 | 43270 | 43270 | ||||||||
17 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | 0.11*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A=% Ash content. | WebFIRE (ID:15) | SLEIS2535918 | 1900 | 400 | 43118 | 43118 | |||||||
18 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | 0.6*A | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:16) | 16 | 300 | 36494 | 43270 | ||||||||
19 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | 0.48*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:18) | 18 | 400 | 36494 | 43270 | ||||||||
20 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 1 | 0.006*A | 100 | Baghouse | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:17) | 17 | 400 | 36494 | 43270 | ||||||||
21 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | SO2 | Sulfur Dioxide | Sulfur Dioxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | 39*SU | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | To determine EF in lb/ton, multiply the EF provided by the weight percent sulfur. S=% Sulfur content. | WebFIRE (ID:20) | 20 | 300 | 43270 | 43270 | ||||||||
22 | 10100101 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Anthracite Coal, Pulverized: Boiler | VOC | Volatile Organic Compounds | Volatile Organic Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.07 | 0 | Uncontrolled | This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee | WebFIRE (ID:21) | 21 | 100 | 43270 | 43270 | |||||||||
23 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7439921 | Lead | Lead Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.0089 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | WebFIRE (ID:32) | 32 | 100 | 43270 | 43270 | |||||||||
24 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7439965 | Manganese | Manganese Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.0036 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:33) | 33 | 100 | 43270 | 43270 | |||||||||
25 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7439976 | Mercury | Mercury Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.00013 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:34) | 34 | 100 | 43270 | 43270 | |||||||||
26 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7440020 | Nickel | Nickel Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.026 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:36) | 36 | 100 | 43270 | 43270 | |||||||||
27 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7440382 | Arsenic | Arsenic Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.00019 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:25) | 25 | 100 | 43270 | 43270 | |||||||||
28 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7440417 | Beryllium | Beryllium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.00031 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:26) | 26 | 100 | 43270 | 43270 | |||||||||
29 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7440439 | Cadmium | Cadmium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.000071 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:28) | 28 | 100 | 43270 | 43270 | |||||||||
30 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7440473 | Chromium | Chromium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.028 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:31) | 31 | 100 | 43270 | 43270 | |||||||||
31 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7782492 | Selenium | Selenium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.0013 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:46) | 46 | 100 | 43270 | 43270 | |||||||||
32 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 7782492 | Selenium | Selenium Compounds | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.00205902 | 121 | Cyclones (Multiple) | Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295. | Based on reported emissions data and engineering judgement. Lack of Supporting Documentation. | WebFIRE (ID:47) | 47 | 200 | 43270 | 43270 | ||||||||
33 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 85018 | Phenanthrene | Polycyclic Organic Matter | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.0068 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:38) | 38 | 1900 | 100 | 43270 | 43270 | ||||||||
34 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 91203 | Naphthalene | Naphthalene | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.13 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:35) | 35 | 100 | 43270 | 43270 | |||||||||
35 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | 92524 | Biphenyl | Biphenyl | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.025 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. October, 1996. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and | WebFIRE (ID:27) | 27 | 100 | 43270 | 43270 | |||||||||
36 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | CO | Carbon Monoxide | Carbon Monoxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.6 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | WebFIRE (ID:30) | 30 | 100 | 43270 | 43270 | |||||||||
37 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | NH3 | Ammonia | Ammonia | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.000565 | 0 | Uncontrolled | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:22) | 22 | 100 | 36770 | 43270 | |||||||||
38 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.63 | 107 | Selective Noncatalytic Reduction for NOx | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:23) | 23 | 200 | 36770 | 43270 | |||||||||
39 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 640 | Anthracite | I | 0 | 0.31 | 139 | Selective Catalytic Reduction (SCR) | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:24) | 24 | 200 | 36770 | 43270 | |||||||||
40 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | NOX | Nitrogen Oxides | Nitrogen Oxides | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 9 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | WebFIRE (ID:37) | 37 | 100 | 43270 | 43270 | |||||||||
41 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | PM-CON | PM Condensible | PM Condensible | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | 0.08*A | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | Multiply the emission factor provided by the weight % ash content of the fuel to obtain the emission factor in lb/ton. Emission factor is for condensible PM. A=% Ash content. | WebFIRE (ID:39) | 39 | 300 | 43270 | 43270 | ||||||||
42 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 4.8 | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | from figure 1.2-2 of section 1.2 AP-42. | WebFIRE (ID:42) | 42 | 100 | 43270 | 43270 | ||||||||
43 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | PM10-PRI | PM10 Primary (Filt + Cond) | PM10 Primary (Filt + Cond) | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | (4.8)+(0.08*A) | 0 | Uncontrolled | This emission factor was derived from other particulate matter emission factors. See Notes. | Sum of PM10-FIL and PM-CON emission factors | WebFIRE (ID:43) | 43 | 300 | 38018 | 43270 | ||||||||
44 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 2.5 | 0 | Uncontrolled | PM Calculator. | Derived factor: 52% of uncontrolled PM10-FIL factor. Fraction of PM10-FIL to PM-FIL is 0.52; PM25-FIL to PM-FIL is 0.27. These fractions are from the PM Calculator. The reference for the fractions is unknown. | WebFIRE (ID:44) | 44 | 100 | 38018 | 43270 | ||||||||
45 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | PM25-PRI | PM2.5 Primary (Filt + Cond) | PM2.5 Primary (Filt + Cond) | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | (2.5)+(0.08*A) | 0 | Uncontrolled | This emission factor was derived from other particulate matter emission factors. See Notes. | Sum of PM25-FIL and PM-CON emission factors | WebFIRE (ID:45) | 45 | 300 | 38018 | 43270 | ||||||||
46 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | SO2 | Sulfur Dioxide | Sulfur Dioxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 1 | 39*SU | 0 | Uncontrolled | (AP42 Text: Section 1.2) EPA. 1995. Section 1.2, Anthracite Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standard | To determine EF in lb/ton, multiply the EF provided by the weight percent sulfur. S=% Sulfur content. | WebFIRE (ID:48) | 48 | 300 | 43270 | 43270 | ||||||||
47 | 10100102 | External Combustion-Electric Generation: Boilers-Anthracite Coal-Boiler, Traveling Grate (Overfeed) Stoker | VOC | Volatile Organic Compounds | Volatile Organic Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 640 | Anthracite | I | 0 | 0.07 | 0 | Uncontrolled | This factor was present in AIRS Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria Air Pollutants, March 1990, EPA 450/4-90-003. These factors may have been (and may still be) in an AP-42 section, or they may have bee | WebFIRE (ID:51) | 51 | 100 | 43270 | 43270 | |||||||||
48 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 206440 | Fluoranthene | Polycyclic Organic Matter | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000169600187 | 0 | Uncontrolled | Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra | 110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation. | WebFIRE (ID:62) | 62 | 1900 | 100 | 43270 | 43270 | |||||||
49 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 218019 | Chrysene | Polycyclic Organic Matter | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0002160002381 | 0 | Uncontrolled | Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra | 110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation. | WebFIRE (ID:61) | 61 | 1900 | 100 | 43270 | 43270 | |||||||
50 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 246 | Polycyclic Organic Matter | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.00023114 | 128 | Electrostatic Precipitator - Dry (DESP) | Composite. Radian FIRE database 1994 release. | Represents both gaseous and particulate POM. Average emission factor from reported values. Lack of Supporting Documentation. | WebFIRE (ID:105) | 105 | 200 | 43270 | 43270 | |||||||||
51 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 246 | Polycyclic Organic Matter | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.014664 | 2 | Wet Scrubber - Medium Efficiency | EPA. May 1988. In: Locating and Estimating Air Emissions from Sources of Polycyclic Organic Matter (POM). EPA-450/4-84-007p. U.S. Environmental Protection Agency. Research Triangle Park, North Carolina. | Represents both gaseous and particulate POM. Lack of Supporting Documentation. | WebFIRE (ID:104) | 104 | 200 | 43270 | 43270 | |||||||||
52 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 50328 | Benzo[a]Pyrene | Polycyclic Organic Matter | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0001944002143 | 0 | Uncontrolled | Johnson, N.D. and M.T. Schultz, ORTECH Corporation. March 15, 1990. In: MOE Toxic Chemical Emissions Inventory for Ontario and Eastern North America, Draft Report. No. P89-50-5429/OG. Prepared for Ontario Ministry of the Environment, Air Resources Bra | 110 - 830 MW operating capacity, 86 - 100% of base load. Lack of Supporting Documentation. | WebFIRE (ID:56) | 56 | 1900 | 100 | 43270 | 43270 | |||||||
53 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7439921 | Lead | Lead Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.013182 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | WebFIRE (ID:66) | 66 | 100 | 36039 | 43270 | |||||||||
54 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7439921 | Lead | Lead Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0133 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Based on literature review. | WebFIRE (ID:65) | 65 | 1998 | 100 | 43270 | 43270 | |||||||
55 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7439965 | Manganese | Manganese Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.049244 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:67) | 67 | 100 | 43270 | 43270 | ||||||||
56 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7439976 | Mercury | Mercury Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000416 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:68) | 68 | 100 | 43270 | 43270 | ||||||||
57 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7440020 | Nickel | Nickel Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.02769 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:70) | 70 | 100 | 43270 | 43270 | ||||||||
58 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7440382 | Arsenic | Arsenic Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.013988 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:55) | 55 | 100 | 43270 | 43270 | ||||||||
59 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7440417 | Beryllium | Beryllium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.002106 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:57) | 57 | 100 | 43270 | 43270 | ||||||||
60 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7440439 | Cadmium | Cadmium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.001482 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:58) | 58 | 100 | 43270 | 43270 | ||||||||
61 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7440473 | Chromium | Chromium Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.03367 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Based on literature review. | WebFIRE (ID:60) | 60 | 100 | 43270 | 43270 | ||||||||
62 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7647010 | Hydrochloric Acid | Hydrochloric Acid | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 1.2 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | WebFIRE (ID:63) | 63 | 100 | 43270 | 43270 | |||||||||
63 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7664393 | Hydrogen Fluoride | Hydrogen Fluoride | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.15 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | WebFIRE (ID:64) | 64 | 100 | 43270 | 43270 | |||||||||
64 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | 7782492 | Selenium | Selenium Compounds | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0006318 | 128 | Electrostatic Precipitator - Dry (DESP) | Krishnan, R.E. and G.V. Helwig. 1982. In: Trace Emissions from Coal and Oil Combustion. Environmental Progress. 1(4): 290-295. | Based on reported emissions data and engineering judgement. Lack of Supporting Documentation. | WebFIRE (ID:106) | 106 | 200 | 43270 | 43270 | ||||||||
65 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | CO | Carbon Monoxide | Carbon Monoxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.5 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Values of 1 or 2 orders of magnitude higher can occur when combustion is not complete. Emission factors for CO2 emissions from coal combustion should be calculated using CO2/ton coal = 73.3C, where C is the wt. percent carbon content of the coal. | WebFIRE (ID:59) | 59 | 100 | 43270 | 43270 | ||||||||
66 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | NH3 | Ammonia | Ammonia | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000565 | 0 | Uncontrolled | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:52) | 52 | 100 | 36770 | 43270 | |||||||||
67 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.63 | 107 | Selective Noncatalytic Reduction for NOx | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:53) | 53 | 200 | 36770 | 43270 | |||||||||
68 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | NH3 | Ammonia | Ammonia | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.31 | 139 | Selective Catalytic Reduction (SCR) | Development and Selection of Ammonia Emission Factors - Final Report. R. Battye, W. Battye, C. Overcash, and S. Fudge; EC/R Incorporated; Durham, NC. Report prepared for USEPA Office of Research and Development; August, 1994. | WebFIRE (ID:54) | 54 | 200 | 36770 | 43270 | |||||||||
69 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | NOX | Nitrogen Oxides | Nitrogen Oxides | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 34 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Expressed as NO2. Generally, 95+ volume % of nitrogen oxides present in combustion exhaust will be in the form of NO, the rest NO2. To express factors as NO, multiply factors by 0.66. | WebFIRE (ID:71) | 71 | 1998 | 100 | 43270 | 43270 | |||||||
70 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | NOX | Nitrogen Oxides | Nitrogen Oxides | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 31 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Expressed as NO2. | WebFIRE (ID:72) | 72 | 100 | 36039 | 43270 | ||||||||
71 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.52 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | (Duplicate Reason: With flue gas desulfurization controls.) Factor is for pulverized coal-fired boilers with all PM controls (with flue gas desulfurization controls). | WebFIRE (ID:77) | 77 | 200 | 36039 | 43270 | ||||||||
72 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM-CON | PM Condensible | PM Condensible | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | ((0.1*SU)-0.03)*26 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt | WebFIRE (ID:75) | 75 | 300 | 38018 | 43270 | ||||||||
73 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | ((0.1*SU)-0.03)*26 | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt | WebFIRE (ID:78) | 78 | 400 | 38018 | 43270 | ||||||||
74 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | ((0.1*SU)-0.03)*26 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | (Duplicate Reason: Without flue gas desulfurization controls.) Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton os subbituminous coal, multiply by 20 M | WebFIRE (ID:76) | 76 | 400 | 36039 | 43270 | ||||||||
75 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM-CON | PM Condensible | PM Condensible | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | ((0.1*SU)-0.03)*26 | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of bituminous coal, multiply by 26 MMBt | WebFIRE (ID:79) | 79 | 400 | 38018 | 43270 | ||||||||
76 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 2.6*A | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Multiply the emission factor provided by the weight percent ash content of the coal to obtain lb/ton EF. A=% Ash content. | WebFIRE (ID:90) | 90 | 300 | 43270 | 43270 | ||||||||
77 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.042*A | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF. | WebFIRE (ID:94) | 94 | 400 | 36495 | 43270 | ||||||||
78 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.042*A | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF. | WebFIRE (ID:93) | 93 | 1998 | 400 | 43270 | 43270 | |||||||
79 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 1.3*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF. | WebFIRE (ID:91) | 91 | 1998 | 400 | 43270 | 43270 | |||||||
80 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-FIL | PM10 Filterable | PM10 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 1.3*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF. | WebFIRE (ID:92) | 92 | 400 | 36495 | 43270 | ||||||||
81 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-PRI | PM10 Primary (Filt + Cond) | PM10 Primary (Filt + Cond) | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 2.6*A | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | WebFIRE (ID:95) | 95 | 1999 | 300 | 36039 | 43270 | ||||||||
82 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-PRI | PM10 Primary (Filt + Cond) | PM10 Primary (Filt + Cond) | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 1.3*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Multiple cyclone estimated control efficiency = 94% | WebFIRE (ID:96) | 96 | 1999 | 400 | 36039 | 43270 | |||||||
83 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM10-PRI | PM10 Primary (Filt + Cond) | PM10 Primary (Filt + Cond) | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.042*A | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP estimated control efficiency = 99.2% | WebFIRE (ID:97) | 97 | 1999 | 400 | 36039 | 43270 | |||||||
84 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 1.48*A | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:98) | 98 | 300 | 36495 | 43270 | ||||||||
85 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.86*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Multiple cyclone estimated control efficiency = 94%. A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:99) | 99 | 400 | 36495 | 43270 | ||||||||
86 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-FIL | PM2.5 Filterable | PM2.5 Filterable | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.022*A | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP estimated control efficiency = 99.2%. A= Coal ash weight percent, as fired. For example if coal ash weight is 8.2% then A=8.2. | WebFIRE (ID:100) | 100 | 400 | 36495 | 43270 | ||||||||
87 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-PRI | PM2.5 Primary (Filt + Cond) | PM2.5 Primary (Filt + Cond) | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 1.48*A | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | WebFIRE (ID:101) | 101 | 1999 | 300 | 36039 | 43270 | ||||||||
88 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-PRI | PM2.5 Primary (Filt + Cond) | PM2.5 Primary (Filt + Cond) | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.86*A | 121 | Cyclones (Multiple) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Multiple cyclone estimated control efficiency = 94% | WebFIRE (ID:102) | 102 | 1999 | 400 | 36039 | 43270 | |||||||
89 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | PM25-PRI | PM2.5 Primary (Filt + Cond) | PM2.5 Primary (Filt + Cond) | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 0.022*A | 128 | Electrostatic Precipitator - Dry (DESP) | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP estimated control efficiency = 99.2% | WebFIRE (ID:103) | 103 | 1999 | 400 | 36039 | 43270 | |||||||
90 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | SO2 | Sulfur Dioxide | Sulfur Dioxide | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 1 | 38*SU | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | Expressed as SO2, including SO2, SO3, and gaseous sulfates. Multiply the emission factor provided by the wt. % sulfur content of the fuel to obtain emission factor in lb/activity units. S=% Sulfur content. | WebFIRE (ID:107) | 107 | 300 | 43270 | 43270 | ||||||||
91 | 10100201 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Wet Bottom | VOC | Volatile Organic Compounds | Volatile Organic Compounds | 8_2 | EPA WebFIRE Emission Factor (pre-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.04 | 0 | Uncontrolled | (AP42 Text: Section 1.1) EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Pla | Nominal values achievable under normal operating conditions. Values one or two orders of magnitude higher can occur when combustion is not complete. | WebFIRE (ID:109) | 109 | 1998 | 100 | 43270 | 43270 | |||||||
92 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 100414 | Ethyl Benzene | Ethylbenzene | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000094 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:151) | 151 | 200 | 43270 | 43270 | ||||||||
93 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 100425 | Styrene | Styrene | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000025 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:283) | 296 | 200 | 43270 | 43270 | ||||||||
94 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 100447 | Benzyl Chloride | Benzyl Chloride | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0007 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:127) | 127 | 200 | 43270 | 43270 | ||||||||
95 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 106934 | Ethylene Dibromide | Ethylene Dibromide | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0000012 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:152) | 152 | 200 | 43270 | 43270 | ||||||||
96 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 107028 | Acrolein | Acrolein | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.00029 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:114) | 114 | 200 | 43270 | 43270 | ||||||||
97 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 107062 | Ethylene Dichloride | Ethylene Dichloride | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.00004 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:153) | 153 | 200 | 43270 | 43270 | ||||||||
98 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 108054 | Vinyl Acetate | Vinyl Acetate | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.0000076 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:300) | 315 | 200 | 43270 | 43270 | ||||||||
99 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 108883 | Toluene | Toluene | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.00024 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:297) | 312 | 200 | 43270 | 43270 | ||||||||
100 | 10100202 | External Combustion-Electric Generation: Boilers-Bituminous/Subbituminous Coal-Bituminous Coal, Pulverized: Boiler, Dry Bottom | 108907 | Chlorobenzene | Chlorobenzene | 8_1 | EPA WebFIRE Emission Factor (post-control) | LB | TON | 663 | Bituminous Coal | I | 0 | 0.000022 | 99 | Other Control Device | (AP42 Text: Section 1.1) EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, | ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER | WebFIRE (ID:138) | 138 | 200 | 43270 | 43270 |