ABCDEFGHIJKLMNOPQRSTUVWXYZAAABACADAEAFAGAHAIAJAKALAMANAOAPAQARASATAUAVAWAXAYAZBABBBCBDBEBFBGBHBIBJBKBLBMBNBOBPBQBRBSBTBUBVBWBXBYBZCACBCCCDCECFCGCHCICJCKCLCMCNCOCPCQCRCSCTCUCV
1
PAINTING SCOPE OF WORK REGISTER
2
3
Document titleScope numberBase scope numberRevision numberRevision dateRevision reasonScope statusApproval statusEffective datePainting contractor legal nameContractor addressContractor phoneContractor emailContractor license numberCustomerOwnerGeneral contractorConstruction managerArchitectInterior designerCoating consultantTesting agencyProject nameProject numberContract numberSubcontract numberPurchase-order numberProject addressBuildingFloorAreaRoomElevationExterior elevationPhaseCost codeSchedule activity IDLimits of workWork-hours restrictionsOccupied-area restrictionsDrawing referencesSpecification referencesFinish-schedule referencesColor-schedule referencesCoating-schedule referencesDetail referencesAddendum referencesRFI referencesApproved-submittal referencesProduct-data referencesSafety-data-sheet referencesSample referencesMockup referencesExisting-condition summaryExisting coating conditionExisting substrate conditionExisting damageExisting moisture conditionExisting contamination concernLead-paint concernHazardous-material concernAccess restrictionsAdjacent finishes to protectFurniture and equipment conditionsSurface scheduleSurface typeSubstrate typeFinish codeColorSheenCoating-system designationApplication methodExact locationQuantityUnit of measureIncluded indicatorExcluded indicatorAllowance indicatorAlternate indicatorUnit-price indicatorWork-by-others indicatorResponsible companyResponsible personCleaning requirementsPressure-washing requirementsDegreasing requirementsScraping requirementsSanding requirementsFeather-sanding requirementsAbrasive-blasting requirementsPower-tool-cleaning requirementsRust-removal requirementsMill-scale-removal requirementsEfflorescence-removal requirementsMold-or-mildew-treatment requirementsStain-blocking requirementsPatching requirementsDrywall-repair requirementsPlaster-repair requirementsConcrete-repair requirements
4
Painting Scope of WorkPAINT2601-PNT-A1-001-R00PAINT2601-PNT-A1-001008/07/2026Initial scopeDraftNot Submitted08/07/2026Example Painting Contractor123 Coating Avenue(000) 000-0000projects@example.comLIC-EXAMPLEExample CustomerExample OwnerExample General ContractorExample CMExample ArchitectExample DesignerExample ConsultantExample Painting ProjectPAINT-2601C-2601SC-099000PO-2601100 Example Finish WayA1East Wing101Phase 109-9000ACT-900Prepare, protect, prime, and finish designated interior wall surfaces in the Level 1 East Wing.A1.00-A9.5009 90 00A9.00CS-01P-1New gypsum board with minor joint and fastener touch-up required.UncoatedReady for preparationFloors, glazing, hardware, devices, and millwork.S-001WallGypsum BoardP-1Example ColorEggshellPrimer plus two finish coatsRollLevel 1 East Wing1000.00SFYesNoNoNoNoNoPainting ContractorExample ForemanRemove dust and surface contaminants.Light sanding between coats as required.Minor surface imperfections only.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78