ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Restroom Piping Systems – Summary
2
Model: 261105 Piping Systems for Stacked Single-User RR · Levels L1–L3 single-user restrooms, risers Garage +10' to L4 · Data exported from Revit 5 Nov 2026
3
4
SystemRevit System NamePipe TypeMaterialSizes UsedFixtures ServedPipe SegmentsFittingsVertical Length (ft)Horizontal Length (ft)Total Length (ft)
5
SanitarySanitary 5PVC - DWV
PVC Sch 40 DWV
4" stack · 4" WC branches · 2" lav branches · 1-1/4" tailpieces
6 WC, 6 Lav383733.637.571.2
6
VentVent 8PVC - DWV
PVC Sch 40 DWV
3" stack · 2" fixture ventsVents all 12 fixtures171345.933.279.1
7
Domestic Cold Water
Domestic Cold Water 5
Copper - Type LCopper Type L2" riser · 1" branches · 1/2" lav supplies6 WC, 6 Lav413440.740.581.2
8
Domestic Hot WaterDomestic Hot Water 7Copper - Type LCopper Type L3/4" riser · 3/4" branches · 1/2" lav supplies6 Lav292541.237.078.2
9
Total125109161.5148.2309.7
10
11
Pipe Length by Level (ft)
12
SystemGarage (riser base + trunk)L1L2L3Total
13
Sanitary21.416.716.716.471.2
14
Vent19.624.319.315.979.1
15
Domestic Cold Water19.924.619.816.981.2
16
Domestic Hot Water19.924.018.815.678.2
17
Total80.889.574.664.8309.7
18
Level = location of each segment's midpoint. Riser segments are split at each floor's branch tees, so most riser length is counted on the floor it passes through; 'Garage' = riser base, elbow and 20' trunk.
19
20
Checks
21
Pipe segments in data125
Should equal Summary total (G9)
22
Fittings in data109
Should equal Summary total (H9)
23
Fixture connectors connected
48 of 48
Read from Revit after final build
24
Open pipe ends8
4 riser tops at L4 + 4 trunk ends at Garage +10' (intentional)
25
Model warnings0
After merging CW/HW systems
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100