1 | Bill Ref. | Description | Quantity | Unit | Rate | Total | |||||||||||||||||||||
2 | Walls & Ceilings | ||||||||||||||||||||||||||
3 | GENERALLY | ||||||||||||||||||||||||||
4 | 16/1A | Tenderers are referred to the Specification for the full particulars of workmanship and materials, and the quantities herein provided shall be read in conjunction with the drawings | Note | 0.00 | |||||||||||||||||||||||
5 | 16/1B | This Builders Bill of Quantities has not been measured in accordance with the Australian Standard Method of Measurement of Building Works, 5th Edition | Note | 0.00 | |||||||||||||||||||||||
6 | REFERENCES | ||||||||||||||||||||||||||
7 | Refer to following architectural drawing series: 0000 for “Overall Site”, 1100 for “GA Plans”, 1500 for “Structural Set Out Plan”, 1700 for “Partition Setout Plan”, 2000 for “Reflected Ceiling Plans”, 3000 for “Elevations”, 4000 for “Sections”, 4500 for “Wall Sections”, 5000 for “Details”, 6000 for “Stairs & Lifts”, 7000 for “Interiors”, 8000 for “Schedules”, 9000 for “Joinery” | Note | 0.00 | ||||||||||||||||||||||||
8 | PRICES | ||||||||||||||||||||||||||
9 | Prices shall include for: | ||||||||||||||||||||||||||
10 | 16/1C | Environmental and sustainable requirements detailed in the Tender documents (if any) | Note | 0.00 | |||||||||||||||||||||||
11 | Wall framing | ||||||||||||||||||||||||||
12 | 16/1D | All shop fabrication work including cutting, notching, milling, machining, drilling, slotted holes, bolting, riveting, welding, grinding and incidental labours | Note | 0.00 | |||||||||||||||||||||||
13 | 16/1E | Marking, delivery, unloading, hoisting, erecting and fixing | Note | 0.00 | |||||||||||||||||||||||
14 | 16/1F | Cutting to dead lengths, notching and machining ends and bearings | Note | 0.00 | |||||||||||||||||||||||
15 | 16/1G | Touching up surface treatment where required | Note | 0.00 | |||||||||||||||||||||||
16 | 16/1H | Bolts and nuts and any type of washer that may be required | Note | 0.00 | |||||||||||||||||||||||
17 | Linings | ||||||||||||||||||||||||||
18 | 16/1J | Notching and fitting around projections, pipes, light fittings, hatches and the like and including cleats, packers, wedges and similar items | Note | 0.00 | |||||||||||||||||||||||
19 | 16/1K | Nails and screws | Note | 0.00 | |||||||||||||||||||||||
20 | 16/2A | Internal and external angles | Note | 0.00 | |||||||||||||||||||||||
21 | 16/2B | Edges set and finished flush with solid plastering in the same plane | Note | 0.00 | |||||||||||||||||||||||
22 | 16/2C | Casing beads | Note | 0.00 | |||||||||||||||||||||||
23 | 16/2D | Cutting and making good around pipes and the like | Note | 0.00 | |||||||||||||||||||||||
24 | Insulation | ||||||||||||||||||||||||||
25 | 16/2E | Laps, square cutting and waste | Note | 0.00 | |||||||||||||||||||||||
26 | 16/2F | Nails, screws, clips, rivets, straps and the like | Note | 0.00 | |||||||||||||||||||||||
27 | 16/2G | Temporary screeds, rules and grounds | Note | 0.00 | |||||||||||||||||||||||
28 | GENERAL ITEMS | ||||||||||||||||||||||||||
29 | 16/2H | Allow for shop drawings if required | 1.00 | Item | 0.00 | ||||||||||||||||||||||
30 | 16/2J | Allow for samples | 1.00 | Item | 0.00 | ||||||||||||||||||||||
31 | 16/2K | Allow for testing | 1.00 | Item | 0.00 | ||||||||||||||||||||||
32 | 16/2L | Allow for contractor's submissions | 1.00 | Item | 0.00 | ||||||||||||||||||||||
33 | 16/2M | Allow for giving notice of and providing facilities for inspection | 1.00 | Item | 0.00 | ||||||||||||||||||||||
34 | 16/2N | Allow for attending on and making good after all other trades, cutting out and making good defective work and for cleaning on completion | 1.00 | Item | 0.00 | ||||||||||||||||||||||
35 | 16/2P | Allow for protecting finished surfaces | 1.00 | Item | 0.00 | ||||||||||||||||||||||
36 | 16/2Q | Allow for covering and protecting surfaces from weather and building operations | 1.00 | Item | 0.00 | ||||||||||||||||||||||
37 | 16/2R | Allow for cleaning on completion | 1.00 | Item | 0.00 | ||||||||||||||||||||||
38 | 16/2S | Allow for maintenance manual | 1.00 | Item | 0.00 | ||||||||||||||||||||||
39 | 16/2T | Allow for warranties | 1.00 | Item | 0.00 | ||||||||||||||||||||||
40 | NOTES AND ASSUMPTIONS | ||||||||||||||||||||||||||
41 | Partitions are measured to the underside of the slab/soffit and are based on the available sections and elevations where partitions are indicated | Note | 0.00 | ||||||||||||||||||||||||
42 | PARTITION AND LININGS | ||||||||||||||||||||||||||
43 | External Walls | ||||||||||||||||||||||||||
44 | Fire Rated Wall | ||||||||||||||||||||||||||
45 | EW-11 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 2x16mm thick EC08 complete plasterboard lining with wall sarking on other side both fixed to 150mm steel stud with 75mm acoustigard 11kg insulation; FRL: -/120/120 | ||||||||||||||||||||||||||
46 | Ground Floor (A-1701-S5) | 17.00 | m2 | 0.00 | |||||||||||||||||||||||
47 | EW-15 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 92mm steel stud with 75mm acoustigard 11kg insulation; FRL: -/120/120 (NB: No details provided, assumed based on EW-01 linings) | ||||||||||||||||||||||||||
48 | Level 1 (A-1702-S5) | 3.00 | m2 | 0.00 | |||||||||||||||||||||||
49 | EW-21 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation on one side and 35mm furring channel with wall sarking on other side; FRL:120/120/120 | ||||||||||||||||||||||||||
50 | Ground Floor (A-1701-S5) | 47.00 | m2 | 0.00 | |||||||||||||||||||||||
51 | Level 1 (A-1702-S5) | 105.00 | m2 | 0.00 | |||||||||||||||||||||||
52 | EW-22 - Dry/- - 35mm furring channel with wall sarking; FRL:120/120/120 (NB: No details provided) | ||||||||||||||||||||||||||
53 | Ground Floor (A-1701-S5) | 76.00 | m2 | 0.00 | |||||||||||||||||||||||
54 | Level 1 (A-1702-S5) | 62.00 | m2 | 0.00 | |||||||||||||||||||||||
55 | EW-23 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation on one side and 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with wall sarking on other side; FRL: 120/120/120 | ||||||||||||||||||||||||||
56 | Ground Floor (A-1701-S5) | 82.00 | m2 | 0.00 | |||||||||||||||||||||||
57 | EW-24 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation; FRL: 120/120/120 | ||||||||||||||||||||||||||
58 | Ground Floor (A-1701-S5) | 12.00 | m2 | 0.00 | |||||||||||||||||||||||
59 | Level 1 (A-1702-S5) | 51.00 | m2 | 0.00 | |||||||||||||||||||||||
60 | Non-Fire Rated Wall | ||||||||||||||||||||||||||
61 | EW-01 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 92mm steel stud with 75mm acoustigard 11kg insulation | ||||||||||||||||||||||||||
62 | Level 1 (A-1702-S5) | 7.00 | m2 | 0.00 | |||||||||||||||||||||||
63 | EW-02 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 150mm steel stud with 75mm acoustigard 11kg insulation | ||||||||||||||||||||||||||
64 | Ground Floor (A-1701-S5) | 160.00 | m2 | 0.00 | |||||||||||||||||||||||
65 | Level 1 (A-1702-S5) | 474.00 | m2 | 0.00 | |||||||||||||||||||||||
66 | EW-10 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 150mm steed stud with 75mm acoustigard 11kg insulation and wall sarking | ||||||||||||||||||||||||||
67 | Ground Floor (A-1701-S5) | 141.00 | m2 | 0.00 | |||||||||||||||||||||||
68 | Internal Walls | ||||||||||||||||||||||||||
69 | Fire Rated Wall | ||||||||||||||||||||||||||
70 | IW-04 - Dry/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud; Acoustic Rating: Rw40; CSR 3017; FRL: 30/30/30 | ||||||||||||||||||||||||||
71 | Ground Floor (A-1701-S5) | 44.00 | m2 | 0.00 | |||||||||||||||||||||||
72 | Level 1 (A-1702-S5) | 29.00 | m2 | 0.00 | |||||||||||||||||||||||
73 | IW-05 - Wet/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud with 75mm acoustigard 11kg insulation; Acoustic Rating: Rw49; CSR 3017; FRL: 30/30/30 | ||||||||||||||||||||||||||
74 | Ground Floor (A-1701-S5) | 333.00 | m2 | 0.00 | |||||||||||||||||||||||
75 | IW-06 - Dry/Dry - 16mm EC08 to both side fixed to 92mm steel stud; Acoustic Rating: Rw41; CSR 3034; FRL: 60/60/60 | ||||||||||||||||||||||||||
76 | Ground Floor (A-1701-S5) | 10.00 | m2 | 0.00 | |||||||||||||||||||||||
77 | Level 1 (A-1702-S5) | 8.00 | m2 | 0.00 | |||||||||||||||||||||||
78 | IW-10 - Dry/Dry - 13mm EC08 complete plasterboard lining to both side fixed to 150mm steel stud with 75mm acoustic 11kg insulation; Acoustic Rating: Rw 50; CSR 3017; FRL: 30/30/30 | ||||||||||||||||||||||||||
79 | Ground Floor (A-1701-S5) | 178.00 | m2 | 0.00 | |||||||||||||||||||||||
80 | Level 1 (A-1702-S5) | 303.00 | m2 | 0.00 | |||||||||||||||||||||||
81 | IW-11 - Dry/Dry - 2x13mm EC08 complete plasterboard lining fixed to 150mm steel stud framing; Acoustic Rating: Rw50; CSR 3043; FRL: 90/90/90 | ||||||||||||||||||||||||||
82 | Ground Floor (A-1701-S5) | 77.00 | m2 | 0.00 | |||||||||||||||||||||||
83 | Level 1 (A-1702-S5) | 58.00 | m2 | 0.00 | |||||||||||||||||||||||
84 | Non-Fire Rated Wall | ||||||||||||||||||||||||||
85 | IW-01 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 35mm furring channel | ||||||||||||||||||||||||||
86 | Ground Floor (A-1701-S5) | 34.00 | m2 | 0.00 | |||||||||||||||||||||||
87 | IW-02 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud | ||||||||||||||||||||||||||
88 | Ground Floor (A-1701-S5) | 21.00 | m2 | 0.00 | |||||||||||||||||||||||
89 | IW-03 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 92mm steel stud | ||||||||||||||||||||||||||
90 | Ground Floor (A-1701-S5) | 88.00 | m2 | 0.00 | |||||||||||||||||||||||
91 | Level 1 (A-1702-S5) | 85.00 | m2 | 0.00 | |||||||||||||||||||||||
92 | IW-04 - Dry/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud | ||||||||||||||||||||||||||
93 | Ground Floor (A-1701-S5) | 11.00 | m2 | 0.00 | |||||||||||||||||||||||
94 | Lining to Internal Walls | ||||||||||||||||||||||||||
95 | Framing support to allow 150kg loading on walls for main learning devices (NB: No details provided, assumed height of 2750mm AFL) | ||||||||||||||||||||||||||
96 | Ground Floor (A-1701-S5) | 20.00 | m2 | 0.00 | |||||||||||||||||||||||
97 | Level 1 (A-1702-S5) | 27.00 | m2 | 0.00 | |||||||||||||||||||||||
98 | Aluminium Windows & Doors | ||||||||||||||||||||||||||
99 | GENERALLY | ||||||||||||||||||||||||||
100 | 22/1A | Tenderers are referred to the Specification for the full particulars of workmanship and materials, and the quantities herein provided shall be read in conjunction with the drawings | Note | 0.00 |