Bill Ref.DescriptionQuantityUnitRateTotal
2
Walls & Ceilings
3
GENERALLY
4
16/1ATenderers are referred to the Specification for the full particulars of workmanship and materials, and the quantities herein provided shall be read in conjunction with the drawingsNote0.00
5
16/1BThis Builders Bill of Quantities has not been measured in accordance with the Australian Standard Method of Measurement of Building Works, 5th EditionNote0.00
6
REFERENCES
7
Refer to following architectural drawing series: 0000 for “Overall Site”, 1100 for “GA Plans”, 1500 for “Structural Set Out Plan”, 1700 for “Partition Setout Plan”, 2000 for “Reflected Ceiling Plans”, 3000 for “Elevations”, 4000 for “Sections”, 4500 for “Wall Sections”, 5000 for “Details”, 6000 for “Stairs & Lifts”, 7000 for “Interiors”, 8000 for “Schedules”, 9000 for “Joinery”Note0.00
8
PRICES
9
Prices shall include for:
10
16/1CEnvironmental and sustainable requirements detailed in the Tender documents (if any)Note0.00
11
Wall framing
12
16/1DAll shop fabrication work including cutting, notching, milling, machining, drilling, slotted holes, bolting, riveting, welding, grinding and incidental laboursNote0.00
13
16/1EMarking, delivery, unloading, hoisting, erecting and fixingNote0.00
14
16/1FCutting to dead lengths, notching and machining ends and bearingsNote0.00
15
16/1GTouching up surface treatment where requiredNote0.00
16
16/1HBolts and nuts and any type of washer that may be requiredNote0.00
17
Linings
18
16/1JNotching and fitting around projections, pipes, light fittings, hatches and the like and including cleats, packers, wedges and similar itemsNote0.00
19
16/1KNails and screwsNote0.00
20
16/2AInternal and external anglesNote0.00
21
16/2BEdges set and finished flush with solid plastering in the same planeNote0.00
22
16/2CCasing beadsNote0.00
23
16/2DCutting and making good around pipes and the likeNote0.00
24
Insulation
25
16/2ELaps, square cutting and wasteNote0.00
26
16/2FNails, screws, clips, rivets, straps and the likeNote0.00
27
16/2GTemporary screeds, rules and groundsNote0.00
28
GENERAL ITEMS
29
16/2HAllow for shop drawings if required1.00Item0.00
30
16/2JAllow for samples1.00Item0.00
31
16/2KAllow for testing1.00Item0.00
32
16/2LAllow for contractor's submissions1.00Item0.00
33
16/2MAllow for giving notice of and providing facilities for inspection1.00Item0.00
34
16/2NAllow for attending on and making good after all other trades, cutting out and making good defective work and for cleaning on completion1.00Item0.00
35
16/2PAllow for protecting finished surfaces1.00Item0.00
36
16/2QAllow for covering and protecting surfaces from weather and building operations1.00Item0.00
37
16/2RAllow for cleaning on completion1.00Item0.00
38
16/2SAllow for maintenance manual1.00Item0.00
39
16/2TAllow for warranties1.00Item0.00
40
NOTES AND ASSUMPTIONS
41
Partitions are measured to the underside of the slab/soffit and are based on the available sections and elevations where partitions are indicatedNote0.00
42
PARTITION AND LININGS
43
External Walls
44
Fire Rated Wall
45
EW-11 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 2x16mm thick EC08 complete plasterboard lining with wall sarking on other side both fixed to 150mm steel stud with 75mm acoustigard 11kg insulation; FRL: -/120/120
46
Ground Floor (A-1701-S5)17.00m20.00
47
EW-15 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 92mm steel stud with 75mm acoustigard 11kg insulation; FRL: -/120/120 (NB: No details provided, assumed based on EW-01 linings)
48
Level 1 (A-1702-S5)3.00m20.00
49
EW-21 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation on one side and 35mm furring channel with wall sarking on other side; FRL:120/120/120
50
Ground Floor (A-1701-S5)47.00m20.00
51
Level 1 (A-1702-S5)105.00m20.00
52
EW-22 - Dry/- - 35mm furring channel with wall sarking; FRL:120/120/120 (NB: No details provided)
53
Ground Floor (A-1701-S5)76.00m20.00
54
Level 1 (A-1702-S5)62.00m20.00
55
EW-23 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation on one side and 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with wall sarking on other side; FRL: 120/120/120
56
Ground Floor (A-1701-S5)82.00m20.00
57
EW-24 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud with 75mm acoustigard 11kg insulation; FRL: 120/120/120
58
Ground Floor (A-1701-S5)12.00m20.00
59
Level 1 (A-1702-S5)51.00m20.00
60
Non-Fire Rated Wall
61
EW-01 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 92mm steel stud with 75mm acoustigard 11kg insulation
62
Level 1 (A-1702-S5)7.00m20.00
63
EW-02 - Ext/Dry - 13mm thick EC08 complete plasterboard lining on one side and 35mm double batten system tophats with wall sarking on other side both sides fixed to 150mm steel stud with 75mm acoustigard 11kg insulation
64
Ground Floor (A-1701-S5)160.00m20.00
65
Level 1 (A-1702-S5)474.00m20.00
66
EW-10 - Ext/Dry - 13mm thick EC08 complete plasterboard lining fixed to 150mm steed stud with 75mm acoustigard 11kg insulation and wall sarking
67
Ground Floor (A-1701-S5)141.00m20.00
68
Internal Walls
69
Fire Rated Wall
70
IW-04 - Dry/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud; Acoustic Rating: Rw40; CSR 3017; FRL: 30/30/30
71
Ground Floor (A-1701-S5)44.00m20.00
72
Level 1 (A-1702-S5)29.00m20.00
73
IW-05 - Wet/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud with 75mm acoustigard 11kg insulation; Acoustic Rating: Rw49; CSR 3017; FRL: 30/30/30
74
Ground Floor (A-1701-S5)333.00m20.00
75
IW-06 - Dry/Dry - 16mm EC08 to both side fixed to 92mm steel stud; Acoustic Rating: Rw41; CSR 3034; FRL: 60/60/60
76
Ground Floor (A-1701-S5)10.00m20.00
77
Level 1 (A-1702-S5)8.00m20.00
78
IW-10 - Dry/Dry - 13mm EC08 complete plasterboard lining to both side fixed to 150mm steel stud with 75mm acoustic 11kg insulation; Acoustic Rating: Rw 50; CSR 3017; FRL: 30/30/30
79
Ground Floor (A-1701-S5)178.00m20.00
80
Level 1 (A-1702-S5)303.00m20.00
81
IW-11 - Dry/Dry - 2x13mm EC08 complete plasterboard lining fixed to 150mm steel stud framing; Acoustic Rating: Rw50; CSR 3043; FRL: 90/90/90
82
Ground Floor (A-1701-S5)77.00m20.00
83
Level 1 (A-1702-S5)58.00m20.00
84
Non-Fire Rated Wall
85
IW-01 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 35mm furring channel
86
Ground Floor (A-1701-S5)34.00m20.00
87
IW-02 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 64mm steel stud
88
Ground Floor (A-1701-S5)21.00m20.00
89
IW-03 - Dry/- - 13mm thick EC08 complete plasterboard lining fixed to 92mm steel stud
90
Ground Floor (A-1701-S5)88.00m20.00
91
Level 1 (A-1702-S5)85.00m20.00
92
IW-04 - Dry/Dry - 13mm thick EC08 complete plasterboard lining to both side fixed to 92mm steel stud
93
Ground Floor (A-1701-S5)11.00m20.00
94
Lining to Internal Walls
95
Framing support to allow 150kg loading on walls for main learning devices (NB: No details provided, assumed height of 2750mm AFL)
96
Ground Floor (A-1701-S5)20.00m20.00
97
Level 1 (A-1702-S5)27.00m20.00
98
Aluminium Windows & Doors
99
GENERALLY
100
22/1ATenderers are referred to the Specification for the full particulars of workmanship and materials, and the quantities herein provided shall be read in conjunction with the drawingsNote0.00